SYSTEM OPERATING ENVELOPE
5°F 75°F
32°F
86°F
14°F
115 °F
63 °F
90°F
-23
-18
-13
-8
-3
2
7
12
17
22
27
32
37
42
47
52
57
-1
4
9
14
19
24
29
34
39
44
49
30
40
50
60
70
80
90
100
110
120
-10
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
Outdoor Temperature (°C)
Indoor Tem
p
eratu
re
(°
C)
Indoor Tem
p
eratu
re
(°
F)
Outdoor Temperature (°F)
Heang Connuous
Operaon
Cooling Connuous
Operaon
NOTE
: If the system operates beyond the conditions presented in this envelope, certain safety protection features may operate
and cause the system to operate abnormally. Optimum performance will be achieved during this operating temperature envelope.
A14466
Fig. 4 – System Operating Envelope
ELECTRICAL DATA
UNIT SIZE
OPER.
VOLTAGE
MAX / MIN*
COMPRESSOR
OUTDOOR FAN
INDOOR FAN
MCA
MAX FUSE
CB AMP
V---PH---HZ
RLA
LRA
V---PH---HZ
FLA
HP
W
V---PH---HZ
FLA
HP
W
9K
127 / 104
115
---
1---60
5.3
10
115---1---60
0.7
0.31
23
115---1---60
0.3
0.020
15
19
30
12K
12K
253 / 187
208---230---1---60
5.3
10
208---230---1---60
0.3
0.33
24
208---230---1---60
0.2
0.027
20
10
15
017K (HP)
018K (AC)
3.95
14
0.6
0.68
50
0.3
0.038
28
14
20
22K
9.7
17
0.6
0.72
53
0.4
0.061
45
16
25
*Permissible limits of the voltage range at which the unit will operate satisfactorily
LEGEND
FLA
--- Full Load Amps
LRA
--- Locked Rotor Amps
MCA
--- Minimum Circuit Amps
RLA
--- Rated Load Amps