![Carrier 38MFC Service Manual Download Page 35](http://html1.mh-extra.com/html/carrier/38mfc/38mfc_service-manual_2560701035.webp)
35
A3 -- Control Board Input/Output Value -- 38--40MFC018---3 (AC) / 38--40MFQ017---3 (HP)
CONNECTOR
38MFC018---3 (AC) / 38MFQ017---3 (HP)
CONTROL BOARD INPUT or OUTPUT VALUE
L_IN
Voltage
:
AC 230V
CN11
Voltage
:
AC230V
CN16
Relative to the N terminal voltage
:
DC 24V
CN6
Maximum output voltage
:
AC230V
CN4
Maximum voltage
:
DC12V
CN5
Maximum voltage between the lines
:
DC12V
P_1
Ground
CN8
Maximum voltage
:
DC5V
CN9
Maximum voltage
:
DC5V
CN10A
Maximum voltage between the lines
:
DC5V
CONNECTOR
40MFC018---3 (AC) / 40MFQ017---3 (HP)
CONTROL BOARD INPUT or OUTPUT VALUE
CN101
Input:Pin1 (5V) Pin2(0-5V),Normal value about5V
CN102
Input:Pin1 (5V) Pin2(0-5V)
CN103
Input:Pin3 & Pin4(5V) Pin1 & Pin5(0-5V)
CN8,CN9
Output:230V High voltage
CN10
Output:Pin1-Pin5(0-230VHigh voltage)
CN5
Output:230V High voltage
CN7
Output:230V High voltage
CN13
Input:230V High voltage
CN12
Input:230V High voltage
CN14
Connection to the earth
CN15
Output:Connection to high voltage
N-B
Output:High voltage
CN11,CN22
Output:High voltage
U V W
Output:Pulse(0-320V)