level could then be checked at another time when the both indoor
and outdoor temperatures are in a more favorable range.

NOTE

: If line length is beyond 80 ft (24.38 m) or greater than 20

ft (6.10 m) vertical separation, See Long Line Guideline for
special charging requirements.

UNIT DAMAGE HAZARD

Failure to follow this caution may result in unit damage.

Compressor damage may occur if system is overcharged.

CAUTION

!

CARE AND MAINTENANCE

For continuing high performance and to minimize possible
equipment failure, it is essential that periodic maintenance be

performed on this equipment. Consult your servicing contractor or
Owner’s Manual for proper frequency of maintenance. Frequency

of maintenance may vary depending upon geographic areas, such

as coastal applications.
Leave Owner’s Manual with homeowner. Explain system

operation and maintenance procedures outlined in manual.

24 VAC HOT

24 VAC COM

R

C

G

W/W1

Y/Y2

R

C

C

A/C

THERMOSTAT

Typical

FAN COIL

AIR

CONDITIONER

G

W2

HEAT STAGE 1

COOL STAGE 1

INDOOR FAN

24 VAC HOT

24 VAC COM

R

C

G

W/W1

Y/Y2

R

C

C

A/C

THERMOSTAT

Typical

FURNACE

AIR

CONDITIONER

Y

G

W

HEAT STAGE 1

COOL STAGE 1

INDOOR FAN

A002326

Fig. 6

---

Generic Wiring Diagrams

(See Thermostat Installation Instructions for wiring specific unit combinations)