4

 

 Accessories

 

* Use with low-ambient controller.

† Fan motor with ball bearings required.

* High-pressure switch must be added if not supplied with the system.
† Do not use in zoning heat pump applications.

 

 ORDERING NUMBER

DESCRIPTION

KAATD0101TDR

 

Time-Delay Relay — All Sizes

 

KSALA0401AAA†

 

MotorMaster®—Low-Ambient Controller — All Sizes

 

HC34GE232 (RCD)

 

Ball Bearing Fan Motor — Size 018

 

HC38GE231 (RCD)

 

Ball Bearing Fan Motor — Size 024–048

 

HC40GE232 (RCD)

 

Ball Bearing Fan Motor — Size 060

 

KAAFT0101AAA*

 

Evaporator Freeze Thermostat — All Sizes

 

KHAIR0101AAA*

 

Isolation Relay — All Sizes

 

KSAHS1501AAA

 

Compressor Start Assist — Capacitor/Relay — Sizes 018–042

 

KSAHS1701AAA

 

Compressor Start Assist — Capacitor/Relay — Size 048

 

KSAHS1601AAA

 

Compressor Start Assist — Capacitor/Relay — Size 060

 

KAACS0201PTC

 

Compressor Start Assist — PTC — All Sizes

 

KAACH1401AAA

 

Crankcase Heater — Size 018

 

KAACH1201AAA

 

Crankcase Heater — Sizes 024–048

 

KSASH1801COP

 

Sound Hood — Sizes 018–030

 

KSASH0601COP

 

Sound Hood — Sizes 036, 042

 

KSASH2101COP

 

Sound Hood — Sizes 048, 060

 

KHAOT0301FST

 

Outdoor Thermostat — All Sizes

 

KHAOT0201SEC

 

Secondary Outdoor Thermostat — All Sizes

 

KSALA0201R22

 

Low-Ambient Pressure Switch Kit — All Sizes

 

KSATX0601HSO

 

Thermostatic Expansion Valve (Hard Shutoff) — Sizes 018–042

 

KSATX0701HSO

 

Thermostatic Expansion Valve (Hard Shutoff) — Size 048

 

KSATX1001HSO

 

Thermostatic Expansion Valve (Hard Shutoff) — Size 060

 

Standard

 

Low-Pressure Switch — All Sizes

 

KHAHI0101HPS

 

High-Pressure Switch — All Sizes

 

P504-8083S (RCD)

 

Liquid-Line Filter Drier (Bi-flow) — Sizes 018–036

 

P504-8163S (RCD)

 

Liquid-Line Filter Drier (Bi-flow) — Sizes 042–060

 

KHALS0401LLS

 

Liquid Solenoid Valve (LSV) — All Sizes

 

KAACF1001MED

 

Coastal Filter Kit — Size 018

 

KAACF1101LRG

 

Coastal Filter Kit — Sizes 024–060

 

THERMOSTAT PKG

DESCRIPTION

TSTATCCPRH01-B†

 

Thermidistat™ Control — Non-Programmable/Programmable Thermostat with Humidity Control (For 
use in Dual Fuel, AC, HP, and 2S applications. Includes Outdoor Air Temperature Sensor.)

 

TSTATCCPDF01-B*

 

Thermostat, Auto Changeover, 7-Day Programmable, °F/°C, Dual Fuel Thermostat,
Must be used with Outdoor Sensor (TSTATXXSEN01-B) Included

 

TSTATCCPHP01-B

 

Thermostat, Auto Changeover, 7-Day Programmable, °F /°C, 2-Stage Heat, 1-Stage Cool

 

TSTATCCNHP01-C

 

Thermostat, Auto Changeover, Non-Programmable, °F /°C, 2-Stage Heat, 1-Stage Cool

 

TSTATCCSHP01

 

Standard Programmable Thermostat — Manual Changeover, 5-2 Day Programmable, °F/°C, 1-Stage 
Heat, 1-Stage Cool

 

TSTATCCBHP01-B

 

Builder’s Thermostat, Manual Changeover, Non-Programmable, °F, 2-Stage Heat, 1-Stage Cool

 

TSTATXXSEN01-B

 

Outdoor Air Temperature Sensor

 

TSTATXXNBP01

 

Backplate for Non-Programmable Thermostat

 

TSTATXXPBP01

 

Backplate for Programmable Thermostat and Thermidistat Control

 

TSTATXXBBP01

 

Backplate for Builder’s Thermostat

 

TSTATXXSBP01

 

Backplate for Standard Programmable Thermostat

 

TSTATXXCNV01

 

Thermostat Conversion Kit (4 to 5 Wire) — 10 Pack

Summary of Contents for 38BYG Series

Page 1: ...ng season All models are listed with UL U S and Canada CEC and ARI FEATURES BENEFITS Electrical Range All units are offered in single phase 208 230v Size Range 38BYG is available in 7 nominal sizes fr...

Page 2: ...ischarge Muffler Incorporated to minimize low frequency sound and pressure pulsation generated by compressor discharge gas Weather Protective Cabinet Steel is protected with a galvanized coating and t...

Page 3: ...2 5 22 40 20 2 6 CONNECTION VALVE In ID Sweat Liquid 5 8 3 4 3 4 3 4 7 8 7 8 7 8 Vapor 3 8 3 8 3 8 3 8 3 8 3 8 3 8 REFRIGERANT TUBES In OD Vapor 5 8 3 4 3 4 3 4 7 8 1 1 8 1 1 8 Liquid 3 8 3 8 3 8 3 8...

Page 4: ...Thermostatic Expansion Valve Hard Shutoff Size 060 Standard Low Pressure Switch All Sizes KHAHI0101HPS High Pressure Switch All Sizes P504 8083S RCD Liquid Line Filter Drier Bi flow Sizes 018 036 P504...

Page 5: ...indoor coil 5 Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles Improves compressor lubrication on restart and mini...

Page 6: ...during operation in cooling mode only For outdoor temperatures down to 20 F 28 9 C it maintains condensing temperature at 100 F 10 F 37 8 C 12 C Usage Guideline A MotorMaster Low Ambient Controller or...

Page 7: ...ce Copper wire must be used from service disconnect to unit All motors compressors contain internal overload protection A weighted sound power dBA NOTE Tested in accordance with ARI Standard 270 95 No...

Page 8: ...16 3 3 16 5 8 3 11 16 18 1 8 19 3 4 21 5 8 14 3 8 18 7 8 22 1 16 10 3 4 11 14 1 4 22 1 2 x 22 1 2 024 30 30 27 15 16 3 3 16 3 4 6 1 2 23 1 2 27 1 4 29 1 8 20 26 3 8 29 9 16 15 1 2 15 11 3 4 30 x 30 0...

Page 9: ...DOOR TEMPERATURE F 10 0 10 20 30 40 50 60 70 80 70 60 50 40 30 20 10 80 38BYG024 F A B 4ANF030 38BYG036 F A B 4AN F B 042 38BYG048 FK4CNB005 38BYG060 FK4CNB006 BASED ON INDOOR ENT AIR AT 70 F AND AT R...

Page 10: ...80 10 65 23 600 3 24 14 100 2 20 7 3 CE3AA030 23 000 NONE 12 00 10 80 23 600 3 32 14 200 2 24 7 5 CF5AA024 22 600 NONE 11 80 10 60 23 600 3 18 14 100 2 18 7 3 CK3BA024 22 400 NONE 11 70 10 75 23 600...

Page 11: ...AA036 28 400 TDR 13 00 11 15 29 000 3 32 17 900 2 38 7 8 CK3BA036 28 800 TDR 13 00 11 35 29 000 3 46 18 000 2 42 7 8 CK5A CK5BA036 28 800 TDR 13 00 11 35 29 000 3 46 18 000 2 42 7 8 CK5A CK5BT036 28 8...

Page 12: ...5A CK5BA042 33 800 TDR 13 50 11 50 35 200 3 60 22 000 2 56 8 0 CK5A CK5BT042 33 800 TDR 13 50 11 50 35 200 3 60 22 000 2 56 8 0 COILS 58CV A X 155 22 VARIABLE SPEED FURNACE CC5A CD5AA042 33 800 TDR 13...

Page 13: ...00 11 50 42 000 3 52 26 600 2 64 8 0 COILS 58CV A X 110 22 VARIABLE SPEED FURNACE CC5A CD5AC048 39 000 TDR 13 00 11 50 42 000 3 28 26 200 2 56 7 8 CC5A CD5AW048 39 000 TDR 13 00 11 65 42 000 3 44 26...

Page 14: ...0 3 62 32 800 2 60 8 0 FC4CN F B 048 46 000 TDR TXV 11 50 9 90 48 000 3 40 32 600 2 50 7 6 FC4CN F B 060 47 500 TDR TXV 11 70 10 00 48 000 3 48 33 000 2 52 7 8 FC4CNB054 48 000 TDR TXV 12 10 10 45 48...

Page 15: ...000 2 40 7 5 CK5A CK5BA060 54 500 TDR 11 50 9 90 60 000 3 28 39 000 2 40 7 5 CK5A CK5BT060 54 500 TDR 11 50 9 90 60 000 3 28 39 000 2 40 7 5 CK5A CK5BX060 56 500 TDR 12 00 10 20 60 000 3 30 38 500 2 4...

Page 16: ...7 5 1 53 17 2 17 1 1 71 16 5 16 5 1 92 15 8 15 8 2 14 15 0 15 0 2 37 57 17 8 17 8 1 53 17 2 17 2 1 72 16 5 16 5 1 91 15 8 15 8 2 12 15 0 15 0 2 38 72 21 6 11 7 1 58 20 7 11 4 1 78 19 7 11 1 1 98 18 7...

Page 17: ...26 3 24 2 22 5 22 5 22 5 14 0 18 5 17 9 22 4 22 5 2 01 2 01 2 01 2 01 2 01 25 2 23 2 21 6 21 7 21 7 13 6 18 2 17 5 21 7 21 7 2 22 2 21 2 21 2 21 2 21 24 2 22 2 20 6 20 9 20 9 13 3 17 8 17 1 20 9 20 9...

Page 18: ...77 25 6 25 6 3 07 24 5 24 5 3 40 23 2 23 2 3 76 27 7 27 7 2 48 26 7 26 7 2 77 25 6 25 6 3 07 24 5 24 5 3 40 23 3 23 3 3 76 Multipliers for Determining the Performance With Other Indoor Sections Indoo...

Page 19: ...31 8 3 28 30 6 30 6 3 60 29 2 29 2 3 94 27 8 27 8 4 32 Multipliers for Determining the Performance With Other Indoor Sections Indoor Section Size Cooling Indoor Section Size Cooling Capacity Power Ca...

Page 20: ...3 87 26 6 22 6 4 24 32 5 31 6 2 92 31 2 30 8 3 21 29 8 29 8 3 53 28 5 28 5 3 87 27 1 27 1 4 25 32 2 32 2 2 92 31 0 31 0 3 21 29 8 29 8 3 53 28 5 28 5 3 87 27 1 27 1 4 25 1350 72 67 63 62 57 39 2 21 5...

Page 21: ...4 35 2 35 2 4 64 4 59 4 54 4 57 4 57 37 4 34 5 32 1 33 6 33 6 22 5 30 8 29 5 33 6 33 6 5 07 5 01 4 96 4 99 4 99 Multipliers for Determining the Performance With Other Indoor Sections Indoor Section Si...

Page 22: ...4 17 4 11 4 07 4 08 4 08 39 4 36 2 33 7 34 4 34 4 22 1 29 6 28 6 34 4 34 4 4 56 4 50 4 45 4 47 4 47 37 3 34 2 31 9 32 8 32 8 21 3 28 9 27 8 32 8 32 8 4 98 4 92 4 87 4 89 4 89 1675 72 67 63 62 57 45 8...

Page 23: ...Other Indoor Sections Indoor Section Size Cooling Indoor Section Size Cooling Capacity Power Capacity Power CC5A CD5AA 060 0 96 1 05 COILS 58CV A X 135 22 VARIABLE SPEED FURNACE CC5A CD5AC 048 0 93 1...

Page 24: ...6 32 49 2 49 2 6 98 46 6 46 6 7 70 2000 72 67 8 35 6 5 39 64 7 34 5 5 96 61 5 33 4 6 59 58 1 32 2 7 26 54 4 31 0 7 99 67 62 6 46 3 5 31 59 7 45 2 5 87 56 6 44 0 6 49 53 4 42 7 7 15 50 0 41 4 7 87 63...

Page 25: ...36 13 1 11 6 1 41 15 3 13 9 1 49 17 8 17 8 1 58 20 5 20 5 1 71 23 6 23 6 1 88 550 8 01 7 37 1 29 9 58 8 81 1 33 11 4 10 4 1 37 13 3 11 8 1 42 15 5 14 1 1 49 18 0 18 0 1 59 20 7 20 7 1 71 23 9 23 9 1...

Page 26: ...5 31 8 31 1 31 5 31 8 2 30 2 25 2 23 75 725 825 925 9 25 9 44 9 61 8 51 8 68 8 84 1 86 1 88 1 91 11 9 12 1 12 2 10 9 11 1 11 2 1 93 1 94 1 96 14 4 14 6 14 8 13 2 13 3 13 5 1 99 2 00 2 01 17 1 17 2 17...

Page 27: ...9 3 29 3 2 76 34 1 34 1 2 98 38 6 38 6 3 12 12 0 11 0 2 22 14 9 13 7 2 30 18 0 16 5 2 37 21 5 19 1 2 47 25 4 23 1 2 60 29 5 29 5 2 76 34 3 34 3 2 93 38 2 38 2 3 07 Multipliers for Determining the Perf...

Page 28: ...2 61 22 1 20 2 2 71 26 2 23 3 2 83 30 7 27 9 2 97 35 7 35 7 3 16 40 6 40 6 3 28 43 6 43 6 3 39 Multipliers for Determining the Performance With Other Indoor Sections Indoor Section Size Heating Indoo...

Page 29: ...39 18 4 16 9 2 48 22 1 20 2 2 57 26 2 23 3 2 70 30 7 27 9 2 84 35 8 35 8 3 03 40 9 40 9 3 17 44 8 44 8 3 32 15 2 14 0 2 43 18 7 17 1 2 51 22 4 20 4 2 60 26 5 23 5 2 72 31 0 28 2 2 86 36 1 36 1 3 03 40...

Page 30: ...3 58 3 60 41 9 42 5 43 0 41 9 42 5 43 0 3 79 3 78 3 79 49 0 49 7 50 3 49 0 49 7 50 3 4 08 4 05 4 05 56 5 57 3 57 9 56 5 57 3 57 9 4 42 4 38 4 38 Multipliers for Determining the Performance With Other...

Page 31: ...16 3 20 31 6 32 0 32 4 28 1 28 4 28 8 3 27 3 28 3 32 36 5 37 0 37 4 33 2 33 7 34 0 3 42 3 43 3 45 42 4 43 0 43 5 42 4 43 0 43 5 3 63 3 62 3 64 49 7 50 4 51 0 49 7 50 4 51 0 3 91 3 89 3 89 57 3 58 1 58...

Page 32: ...rs for Determining the Performance With Other Indoor Sections Indoor Section Size Heating Indoor Section Size Heating Capacity Power Capacity Power CC5A CD5AA 060 1 00 1 10 COILS 58CV A X 135 22 VARIA...

Page 33: ...5 57 69 3 69 3 5 97 79 7 79 7 6 41 2000 28 1 25 9 4 41 33 5 30 8 4 59 39 2 35 7 4 77 45 3 40 2 4 96 52 5 47 8 5 20 60 6 60 6 5 49 70 1 70 1 5 87 79 2 79 2 6 18 2250 28 5 26 2 4 45 33 8 31 1 4 61 39 5...

Page 34: ...unit should be level in all horizontal planes 7 Maximum elevation of indoor coil above or below base of outdoor unit is indoor coil above 50 ft indoor coil below 150 ft See items 8 and 9 following 8...

Page 35: ...35...

Page 36: ...d start up Unit Cabinet Unit cabinet will be constructed of galvanized steel bonderized and coated with a powder coat paint Fans Condenser fan will be direct drive propeller type discharging air upwar...

Reviews: