27
Heat pump heating performance continued
See notes on pg. 28.
INDOOR
AIR
OUTDOOR COIL ENTERING AIR TEMPERATURES
°
F
–3
7
17
27
37
47
57
67
Capacity
MBtuh
Total
Power
Capacity
MBtuh
Total
Power
Capacity
MBtuh
Total
Power
Capacity
MBtuh
Total
Power
Capacity
MBtuh
Total
Power
Capacity
MBtuh
Total
Power
Capacity
MBtuh
Total
Power
Capacity
MBtuh
Total
Power
EDB
CFM
Total Integ* kW†
Total Integ* kW†
Total Integ* kW†
Total Integ* kW†
Total Integ* kW†
Total Integ* kW†
Total Integ* kW†
Total Integ* kW†
38BYC048-33, 34 Outdoor Section With 40FK(A,B)/FK4(C,D)NF005 Indoor Section
65
1400
22.2
20.4
2.99
26.7
24.6
3.13
31.4
28.6
3.25
36.3
32.2
3.38 42.1
38.3
3.54
48.5
48.5
3.73
56.1
56.1
3.97
64.6
64.6
4.29
1600
22.5
20.7
3.00
27.0
24.8
3.13
31.7
28.9
3.23
36.6
32.5
3.35 42.5
38.6
3.48
49.1
49.1
3.66
56.7
56.7
3.88
65.4
65.4
4.18
1800
22.7
20.9
3.02
27.2
25.0
3.13
32.0
29.1
3.23
36.9
32.8
3.33 42.8
39.0
3.46
49.5
49.5
3.62
57.2
57.2
3.83
66.0
66.0
4.12
70
1400
21.7
19.9
3.13
26.4
24.3
3.28
31.1
28.4
3.42
35.9
31.9
3.56 41.6
37.9
3.73
48.0
48.0
3.93
55.4
55.4
4.19
63.7
63.7
4.51
1600
22.0
20.2
3.14
26.7
24.5
3.28
31.4
28.6
3.40
36.3
32.2
3.53 42.0
38.2
3.67
48.5
48.5
3.85
56.0
56.0
4.09
64.5
64.5
4.40
1800
22.3
20.5
3.16
27.0
24.8
3.29
31.7
28.9
3.40
36.6
32.5
3.51 42.4
38.6
3.65
48.9
48.9
3.81
56.5
56.5
4.03
65.1
65.1
4.33
75
1400
21.1
19.4
3.26
26.0
23.9
3.43
30.8
28.1
3.60
35.6
31.6
3.75 41.2
37.5
3.93
47.5
47.5
4.14
54.7
54.7
4.41
62.9
62.9
4.75
1600
21.4
19.7
3.28
26.3
24.2
3.43
31.1
28.4
3.58
35.9
31.9
3.71 41.6
37.8
3.87
48.0
48.0
4.06
55.3
55.3
4.31
63.7
63.7
4.62
1800
21.7
20.0
3.30
26.6
24.4
3.44
31.4
28.6
3.57
36.2
32.1
3.69 41.9
38.1
3.84
48.4
48.4
4.01
55.8
55.8
4.24
64.3
64.3
4.55
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section
Size
Heating
Indoor
Section
Size
Heating
Capacity
Power
Capacity
Power
CC5A/CD5AA
060
1.00
1.10
40FK(A,B)/FK4(C,D)NB
006
1.00
0.96
CC5A/CD5AC
048
1.00
1.15
40FK(A,B)/FK4(C,D)NF
005
1.00
1.00
CC5A/CD5AW
048
1.00
1.09
COILS + 58CV(A,X)090-16 FURNACE
060
1.00
1.05
CE3AA
060
1.00
1.05
CD5AA
048
1.00
1.09
COILS + 58CV(A,X)110-22 FURNACE
CE3AA
048
1.00
1.07
CC5A/CD5AA
060
1.00
1.10
060
1.00
1.04
CE3AA
060
1.00
1.04
CF5AA
048
1.00
1.11
CK3BA
060
1.00
1.00
CK3BA
048
1.00
1.07
CK5A/CK5BA
060
1.00
1.00
060
1.00
1.02
CK5A/CK5BT
060
1.00
1.00
CK5A/CK5BA
048
1.00
1.07
CK5A/CK5BX
060
1.00
0.99
060
1.00
1.02
COILS + 58CV(A,X)135-22 FURNACE
CK5A/CK5BN
048
1.00
1.09
CC5A/CD5AA
060
1.00
1.10
060
1.00
1.01
CC5A/CD5AW
060
1.00
1.04
CK5A/CK5BT
048
1.00
1.07
CE3AA
060
1.00
1.04
060
1.00
1.02
CK3BA
060
1.00
1.00
CK5A/CK5BW
048
1.00
1.07
CK5A/CK5BA
060
1.00
1.00
CK5A/CK5BX
060
1.00
1.01
CK5A/CK5BT
060
1.00
1.00
F(A,B)4(A,B)N(F,B,C)
048
1.00
1.05
CK5A/CK5BX
060
1.00
0.99
060
1.00
1.03
COILS + 58CV(A,X)155-22 FURNACE
FB4(A,B)NB
070
1.00
0.99
CC5A/CD5AA
060
1.00
1.10
FC4(B,C)NB
054
1.00
0.98
CC5A/CD5AW
060
1.00
1.04
070
1.00
0.99
CE3AA
060
1.00
1.03
FC4(B,C)N(F,B)
048
1.00
1.05
CK3BA
060
1.00
0.99
060
1.00
1.03
CK5A/CK5BA
060
1.00
0.99
FG3AAA
048
1.00
1.07
CK5A/CK5BT
060
1.00
0.99
060
1.00
1.06
CK5A/CK5BX
060
1.00
0.99