![Carrier 38AUQ 16 Series Installation, Start-Up And Service Instructions Manual Download Page 7](http://html1.mh-extra.com/html/carrier/38auq-16-series/38auq-16-series_installation-start-up-and-service-instructions-manual_2563136007.webp)
7
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18
3
8 A U Q A 2
5
A 0
C 6
–
0
A 0
A 0
Model Type
Packaging
38AU= Carrier Condensing Unit
R--- 410A Refrigerant
0 = Standard
Type of Coil
Electrical Options
Q = Heat Pump Scroll Compressor
A = None
C = Non-Fused Disconnect
1 = LTL
Service Options
0 = None
1 =
Not Used
A = Place Holder
Base Unit Controls
0 = Electro-Mechanical Controls
Design Revision
Voltage
1 = 575/3/60
5 = 208/ 230/3/60
6 = 460/3/60
2 = Powered Convenience Outlet
Puron
r
1 = Un-powered Convenience Outlet
_____________
____
Nominal Tonnage
16 = 15 Tons
25 = 20 Tons
Refrigerant Options
A = None
B = Low Ambient
A = Initial Rev (Discrete Model Number)
Not Used
A = Not Used
Not Used
0 = Not Used
M = Al/Cu with Hail Guard
N = Precoat Al/Cu with Hail Guard
P = E-Coat Al/Cu with Hail Guard
R = Cu/Cu with Hail Guard
Coil Options
A = Al/Cu
B = Precoat Al/Cu
C = E-Coat Al/Cu
E= Cu/Cu
C10676
Fig. 3 -- Model Number Nomenclature
S
E
T
A
N
G
I
S
E
D
N
O
I
T
I
S
O
P
)
r
a
d
n
e
l
a
c
l
a
c
s
i
f
(
e
r
u
t
c
a
f
u
n
a
m
f
o
k
e
e
W
1−2
)
A
S
U
,
s
a
x
e
T
,
P
T
E
=
G
(
n
o
i
t
a
c
o
l
g
n
i
r
u
t
c
a
f
u
n
a
M
5
r
e
b
m
u
n
l
a
i
t
n
e
u
q
e
S
6−10
1
2
3
4
5
6
7
8
9
10
4
8
1
0
G
1
2
3
4
5
POSITION NUMBER
TYPICAL
Year of manufacture (”10” = 2010)
3−4
C10799
Fig. 4 -- Serial Number Nomenclature
.
INSTALLATION
Jobsite Survey
Complete the following checks before installation.
1. Consult local building codes and the NEC (National
Electrical Code) ANSI/NFPA 70 for special installa-
tion requirements.
2. Determine unit location (from project plans) or select
unit location.
3. Check for possible overhead obstructions which may
interfere with unit lifting or rigging.
Step 1 — Plan for Unit Location
Select a location for the unit and its support system (pad,
rails or other) that provides for the minimum clearances
required for safety. This includes the clearance to
combustible surfaces, unit performance and service access
below, around and above unit as specified in unit
drawings. See Fig. 5.
Select a unit mounting system that provides adequate
height to allow for removal and disposal of frost and ice
that will form during the heating-defrost mode.
NOTE
: Consider also the effect of adjacent units on
airflow performance and control box safety clearance.
38A
U
Q
Summary of Contents for 38AUQ 16 Series
Page 4: ...4 C10675 Fig 2 38AUQ 25 Unit Dimensions 38AUQ...
Page 19: ...19 C10784 Fig 16 38AUQ 16 Charging Chart 38AUQ...
Page 20: ...20 C10785 Fig 17 38AUQ 25 Charging Chart 38AUQ...
Page 21: ...21 C10786 Fig 18 38AUQ 16 Power Schematic 208 230 3 60 shown 38AUQ...
Page 22: ...22 C10787 Fig 19 38AUQ 25 Power Schematic 208 230 3 60 shown 38AUQ...
Page 23: ...23 C10788 Fig 20 38AUQ 16 25 Control Schematic 38AUQ...
Page 41: ...41 C10363 Fig 35 Wind Baffles Fabrication 38AUQ...
Page 42: ...42 C10366 Fig 36 15 Ton Wind Baffle Brackets Fabrication 38AUQ...
Page 44: ...44 RIGHT BACK LEFT FRONT C10368 Fig 38 Wind Baffle Installation 20 Ton Units 38AUQ...
Page 45: ...45 38AUQ...