Step 2—Install Air Cleaner Filter Gage

Blower suction will create a slight vacuum so air will flow into the
bottom of the filter gage and through its chamber—lifting the ball
in the gage. As the filter media in the air cleaner becomes dirty, the
increase in vacuum and resulting airflow will lift the ball propor-
tionally. When the ball reaches the top arrow, the air cleaner media
should be replaced.

The air cleaner filter gage should be installed in a convenient
location on a vertical duct surface between the air cleaner and the
furnace blower or in the furnace casing of the blower compart-
ment.

1. Drill a 3/8-in. hole in duct work or casing. Place spring gage

holder in hole. (See Fig. 4.)

2. Insert gage mounting stud through hole in condition indicator

card and then in spring gage holder so stud projects into duct
or casing. (See Fig. 4.)

3. Adjust airflow gage by rotating range adjustment plug until

ball hovers at tip of lower arrow. (See Fig. 4.)

When the air cleaner media begins to become clogged and dirty,
the ball will move up the gage. When the ball is in the red range
(shown on the condition indicator card), the air cleaner should be
serviced.

Step 3—Install Filter Media in Air Cleaner Cabinet

NOTE:

These instructions should also be followed when the filter

gage indicates the filter media needs to be changed.

1. Loosen two thumb screws on front access panel and remove

panel. Slide filter media frame assembly from air cleaner
cabinet.

2. Remove filter media from carton. Ensure there are no holes or

tears in filter media.

Fig. 2—Dimensional Drawing

A90295

13

16

1

4

19 

13

16

15

16

3

4

3

16

5

8

15

16

7

8

5

16

25 

11

16

23 

5

16

21 

1

2

1

8

6

21 

7

16

19 

13

16

1

2

1

2

KNURLED THUMBSCREW
WITH .130 IN. DIA STARTER
POINT.

13

16

Fig. 3—Typical Installations (Upflow Furnaces)

A90294

AIR  FLOW

FURNACE  WITH

TRANSITION

FURNACE  NO

TRANSITION

FURNACE  WITH

TURNING  VANES

AIR  FLOW

AIR  FLOW

2

Summary of Contents for 31MF

Page 1: ...nd property damage INTRODUCTION The Model 31MF High Efficiency Mechanical Air Cleaner is designed for installation in the return air duct of any forced air heating and or cooling system It is designed for use in systems with airflow up to 2000 cfm For higher airflows additional units may be required The Model 31MF is a mechanical air cleaner incorporating 78 sq ft of glass microfiber filter media ...

Page 2: ...t airflow gage by rotating range adjustment plug until ball hovers at tip of lower arrow See Fig 4 When the air cleaner media begins to become clogged and dirty the ball will move up the gage When the ball is in the red range shown on the condition indicator card the air cleaner should be serviced Step 3 Install Filter Media in Air Cleaner Cabinet NOTE These instructions should also be followed wh...

Page 3: ...c pleat spacers being careful to insert one support finger between each pleat Press the pleat spacers down firmly to fully engage guide pin at each end See Fig 6 6 Slide assembled media frame into air cleaner cabinet Be sure airflow arrow on media frame is in same direction as arrow in cabinet Plastic pleat spacers are always on downstream side of filter media Attach outer cover and tighten thumb ...

Page 4: ...9011 Manufacturer reserves the right to discontinue or change at any time specifications or designs without notice and without incurring obligations Book 1 4 Tab 7a 9a PC 101 Catalog No 533 132 Printed in U S A Form 31MF 2SI Pg 4 12 91 Replaces 31MF 1SI ...

Reviews: