Page 1
PLAN
VIEW
SIDE
ELEVATION
Wiring access
024 - as shown.
036 & 065, drill
holes & fit
grommets as
necessary.
water pipe
connections
direction
of air flow
600mm min, clearance
for service access.
T
RANSPORT
D
AMAGE
As soon as the unit is delivered to site, check
for evidence of freight damage. If there is any
damage, file a claim with the transport
company immediately, and contact your
Carrier representative.
L
OCATION OF
U
NIT
•
Consult local building codes for any
special building requirements and noise
level limitations.
•
Leave sufficient clearance around the unit
for service access and for proper air flow
through the unit.
•
Avoid complaints from neighbours by
locating the unit away from neighbouring
structures such as windows or hard
surfaces that might reflect and amplify
noise.
W
EATHER
P
ROOF
Carrier Heat Pumps are completely weather
proof and are suitable for mounting indoors
(e.g. garages, etc) or outdoors.
M
OUNTING
The unit should be mounted on a level base,
ideally a concrete slab, or equivalent
structure.
I
NDOOR
I
NSTALLATION
When mounted indoors, the Heat Pump outlet
should exhaust to outside and have a 600mm
minimum clearance on the side indicated
below, for service access. The Heat Pump
needs to draw air from inside the room, so
ensure there is some means for the air to
seep in. (wall grille, door grille, etc..)
SWIMMING POOL HEAT PUMP
world leader in air
conditioning and
heating
technology
Installation &
Startup
Instructions
30ZQ024-G
30ZQ036
30ZQ065
30ZQ036