5
PHYSICAL DATA
UNIT SIZE SERIES
24---30
36---30
48---30
60---30
Operating Weight lb (kg)
324 (147)
324 (147)
334 (152)
334 (152)
Shipping Weight lb (kg)
367 (167)
367 (167)
375 (170)
375 (170)
Compressor Type
Variable Speed Scroll
REFRIGERANT
Puron
®
(R---410A)
Control
TXV (Puron
®
Hard Shutoff)
Charge lb (kg)
13.12 (5.95)
13.12 (5.95)
13.30 (6.03)
13.30 (6.03)
Outdoor Htg Exp. Device
EXV
EXV
EXV
EXV
COND FAN
Forward Swept Propeller Type, Direct Drive
Air Discharge
Vertical
Air Qty (CFM)
2700
4269
4350
5000
Motor HP
1/3
1/3
1/3
1/3
Motor RPM
500---900
500---900
500---900
500---900
COND COIL
Face Area (Sq ft)
30.25
30.25
30.25
30.25
Fins per In.
20
20
20
20
Rows
2
2
2
2
Circuits
8
8
9
9
VALVE CONNECT. (In. ID)
Vapor
7/8
7/8
7/8
7/8
Liquid
3/8
REFRIGERANT TUBES (In. OD)
Rated Vapor*
7/8
7/8
1---1/8
1---1/8
Max Liquid Line
3/8
* Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset.
Note
: See unit Installation Instruction for proper installation.
ACCESSORIES
KIT NUMBER
KIT NAME
24---30
36---30
48---30
60---30
KHAEM0101EMI
ELECTRO---MAGNETIC INTERFERENCE
KIT
X
X
X
X
KHALS0401LLS
SOLENOID VALVE
X
X
X
X
KHASS0606MPK*
SNOW STAND
X
X
X
X
KSASF0101AAA
SUPPORT FEET
X
X
X
X
KSATX0301PUR
TXV
X
X
KSATX0401PUR
TXV
X
KSATX0501PUR
TXV
X
STANDARD
CRANKCASE HEATER
S
S
S
S
x = Accessory S = Standard * Available from RCD
CONTROLS
SYSTXCCITN01
Infinity Touch Control (non---Wi---Fi)
SYSTXCCITW01
Infinity Touch Control with Wi---Fi & Wireless Access Point
SYSTXCCUID01---V
Infinity Control Deluxe 7---Day Programmable (Wall---mounted system control.)
SYSTXCCUIZ01---V
Infinity Control Deluxe Zoning 7---Day Programmable (Wall---mounted control for a multi---zone system.)
SYSTXCC4ZC01
Infinity 4---Zone Damper Control Module (Wall---mounted control for a four---zone system.)
SYSTXCCSMS01
Infinity Smart Sensor (Optional wall control used to monitor temperature and/or fan control in an individual zone.)
SYSTXCCRRS01
Infinity Remote Room Sensor (Monitors temperature in an individual zone.)
SYSTXCCRCT01 or
SYSTXCCRWF01
Infinity System Access Module (Hardware for wireless access and control via internet.)
SYSTXCCNIM01
Infinity Network Interface Module (Connects Heat Recovery and Energy Recovery Ventilators on non---zoning
applications.)
SYSTXX0LBP01
Decorative Back Plate for Infinity Control (Decorative wall plate.)
25V