24ABR3

Base

t

Series 13 Air Conditioner

Sizes 18 to 60

1---1/2 to 5 Nominal Tons

Product Data

A05341

INDUSTRY LEADING

FEATURES / BENEFITS

Efficiency

S

13 SEER/11 EER (Nominal)

S

Microtube Technology

t

refrigeration system

S

Indoor air quality accessories available

Sound

S

Sound level as low as 76 dBA

S

As low as 73 dBA with optional accessory sound hood

Comfort

S

System supports Thermidistat

t

or standard thermostat

controls

Reliability

S

Front--seating service valves

S

Scroll compressor

S

Internal pressure relief valve

S

Internal thermal overload

S

Filter drier

S

Balanced refrigeration system for maximum reliability

Durability

WeatherArmor

t

protection package:

S

Solid, Durable sheet metal construction

S

Wire coil guard

S

Baked--on, complete coverage, powder paint

Applications

S

Long--line -- up to 250 feet total equivalent length, up
to 200 feet condenser above evaporator, or up to 80 ft.
evaporator above condenser (See Longline Guide for

more information.)

S

Low ambient (down to --20

_

F) with accessory kit

Warranty

Single Phase

S

5 year limited compressor warranty

S

5 year limited parts warranty

Three Phase

S

5 year limited compressor warranty

S

1 year limited parts warranty

Summary of Contents for 24ABR3

Page 1: ...S Internal pressure relief valve S Internal thermal overload S Filter drier S Balanced refrigeration system for maximum reliability Durability WeatherArmort protection package S Solid Durable sheet me...

Page 2: ...Partner Carrier Corporation has determined that this product meets the ENERGY STAR guidelines for energy efficiency Refer to the combination ratings in Product Data for system combinations that meet...

Page 3: ...stem operation The maximum allowable total equivalent length is 250Ft The maximum vertical separation is 200 Ft when outdoor unit is above indoor unit and up to 60 Ft when the outdoor unit is below th...

Page 4: ...PROTECTOR X X X X X X X X X X X X X X X X X X X KAAFT0101AAA FREEZE THERMOSTAT X X X X X X X X X X X X X X X X X X X KSAHS1501AAA HARD START CAP RELAY X X X X X X X KSAHS1701AAA HARD START CAP RELAY...

Page 5: ...compressor lubrication on restart and minimizes the chance of liquid slugging Usage Guideline Required in low ambient cooling applications Required in Longline applications Suggested in all commercial...

Page 6: ...Hard shut off types are available NOTE When using a hard shut off TXV with single phase reciprocating compressors a Compressor Start Assist Capacitor and Relay is required Usage Guideline Required to...

Page 7: ...olid wire for 10 AWG or smaller stranded wire for larger than 10 AWG is used consult applicable tables of the NEC ANSI NFPA 70 Length shown is as measured 1 way along wire path between unit and servic...

Page 8: ...8 DIMENSIONS NOTE Optional dense coil guard shown 24ABR3...

Page 9: ...14 00 11 50 58MVB040 14 CSRH 2412A 17 400 TDR TXV 14 00 11 50 58MVB060 14 CSRH 2412A 17 400 TDR TXV 14 00 11 50 58MVB080 14 CSRH 2412A 17 400 TDR TXV 14 00 11 50 58CV A X 070 12 CSRH 2412A 17 400 TDR...

Page 10: ...R TXV 14 00 11 50 58CV A X 155 22 CNRF 2418A 23 000 TXV 13 00 11 00 CSRH 2412A 23 000 TXV 13 00 11 00 CSRH 2412A 22 800 TDR TXV 14 00 11 50 58MVB040 14 CSRH 2412A 22 800 TDR TXV 14 00 11 50 58MVB060 1...

Page 11: ...621A 28 000 TDR TXV 14 00 11 50 58CV A X 110 20 CNRH 3017A 28 000 TXV 13 00 11 00 CNRH 3017A 27 800 TDR TXV 14 00 11 50 58MVB040 14 CNRH 3017A 27 800 TDR TXV 14 00 11 50 58MVB060 14 CNRH 3017A 27 800...

Page 12: ...00 11 50 FK4DNF005 29 200 TDR TXV 14 00 11 50 36 31 36 51 36 61 CAR 3617A 34 000 TXV 13 00 11 00 CAR 3614A 33 000 TXV 13 00 11 00 CAR 3614A 33 000 TDR TXV 13 50 11 20 58CV A X 070 12 CAR 3617A 34 000...

Page 13: ...SRH 3612A 34 000 TXV 13 00 11 00 CSRH 3612A 33 800 TDR TXV 13 50 11 20 58MVB040 14 CSRH 3612A 33 800 TDR TXV 14 00 11 50 58MVB060 14 CSRH 3612A 33 800 TDR TXV 13 50 11 20 58MVB080 14 CSRH 3612A 33 800...

Page 14: ...1 500 TXV 13 00 11 00 CNRV 4821A 41 000 TDR TXV 13 50 11 20 58MVB080 14 CNRV 4821A 41 000 TDR TXV 13 50 11 20 58MVB080 20 CNRV 4821A 41 000 TDR TXV 14 00 11 50 58MVB100 20 CNRV 4821A 41 000 TDR TXV 14...

Page 15: ...14 00 11 50 58CV A X 155 22 FA4CN F C 042 41 000 TDR TXV 13 00 11 00 FA4CN F C 048 41 500 TDR TXV 13 00 11 00 FC4DN F B 042 41 500 TDR TXV 13 50 11 20 FC4DN F B 048 42 500 TDR TXV 14 00 11 50 FK4DNF00...

Page 16: ...4812A 45 000 TDR TXV 13 20 11 00 58MVB100 20 CSRH 4812A 45 000 TDR TXV 13 20 11 00 58MVB120 20 CSRH 4812A 45 000 TDR TXV 13 50 11 20 58CV A X 090 16 CSRH 4812A 45 000 TDR TXV 13 50 11 20 58CV A X 110...

Page 17: ...r the accessory Time Delay Relay KAATD0101TDR or a furnace equipped with TDR Most Carrier furnaces are equipped with TDR EER Energy Efficiency Ratio SEER Seasonal Energy Efficiency Ratio TDR Time Dela...

Page 18: ...11 34 1 77 18 52 11 15 2 08 17 45 10 78 1 65 67 19 41 15 40 1 20 18 45 15 01 1 34 17 59 14 66 1 52 16 90 14 38 1 76 16 39 14 17 2 05 15 90 13 97 2 34 62 18 01 18 01 1 20 17 27 17 27 1 34 16 61 16 61...

Page 19: ...1 00 1 00 CSRH 3012A 1 02 1 02 FA4CN F C 024 0 99 0 99 FA4CN F C 030 1 00 1 00 FC4DNF024 1 01 0 99 FC4DNF030 1 02 0 97 FF1DNA024 0 97 0 99 FF1ENE024 0 98 0 98 FF1ENE030 1 01 1 01 FK4DNF001 1 00 0 96 F...

Page 20: ...4DNF030 1 01 1 00 FF1ENE030 0 99 0 99 FF1ENE036 1 01 1 01 FK4DNF001 1 00 0 96 FK4DNF002 1 01 0 97 FK4DNF003 1 01 0 97 FK4DNF005 1 04 1 00 CAR 3014A 0 99 0 95 58CV A X 070 12 CAR 3614A 0 99 0 95 58CV A...

Page 21: ...F003 1 01 0 97 FK4DNF005 1 05 1 01 CAR 3614A 0 97 0 95 58CV A X 070 12 CNRH 3617A 0 99 0 98 58CV A X 070 12 CNRH 4221A 1 01 0 96 58CV A X 070 12 CSRH 3612A 0 99 0 95 58CV A X 070 12 CSRH 4212A 1 01 0...

Page 22: ...212A 0 99 0 97 58CV A X 070 12 CSRH 4812A 1 00 0 98 58CV A X 070 12 CAR 4817A 0 99 0 94 58CV A X 090 16 CNRH 4221A 0 99 0 94 58CV A X 090 16 CNRH 4821A 1 01 0 97 58CV A X 090 16 CSRH 4212A 0 99 0 94 5...

Page 23: ...1 03 CNRF 4818A 0 98 0 98 CNRH 4821A 1 00 1 00 CNRH 6024A 1 03 1 03 CNRV 4821A 1 00 1 00 CNRV 4824A 1 01 1 01 CNRV 6024A 1 03 1 03 CSRH 4812A 1 00 1 00 CSRH 6012A 1 03 1 03 FA4CN F C 048 1 02 1 02 FA...

Page 24: ...2 6 88 62 55 68 51 26 4 05 53 67 50 29 4 51 51 58 49 26 5 02 49 44 48 17 5 58 47 23 46 96 6 19 45 15 45 15 6 85 57 54 31 54 31 4 05 52 67 52 67 4 51 50 94 50 94 5 02 49 13 49 13 5 58 47 20 47 20 6 19...

Page 25: ...ondenser fan motors will be totally enclosed 1 phase type with class B insulation and permanently lubricated bearings Shafts will be corrosion resistant Fan blades will be statically and dynamically b...

Page 26: ...Morris St S Indianapolis IN 46231 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Catalog No 24ABR3 2PD Replaces 24ABR3 1PD Pri...