NOTES TO USERS

 

Thank you for purchasing Carrier Absorption Chiller. 
Before operating the Chiller, please read this manual thoroughly. 

 

Please  utilize  the  Chiller  to  its  optimum  performance  by  following  recommended  daily  maintenance  and  handling,  and 
periodic service. 

 

If you need any information about maintenance contract or any other inquiries, please contact Carrier service agent. 

 
 

DECLARATION OF CONFORMITY < for CE marking model >

 

This product is marked " CE " as it satisfied EEC Directive No. 2006/42/EC, 2014/30/EU, 97/23/EC, 2009/142/EC and 
conforms with following standards.   

 

This declaration will become void in case of misusage and/or from non observance though partial of Manufacturer's 
installation and/or operating instructions. 

 

Class and group description (EN 55011, clause 5.1) 
This  is  group  1,  class  A  product  according  to  EN  55011.  This  means  that  this  product  does  not  generate  and/or  use 
intentionally  radio-frequency  energy,  in  the  form  of  electromagnetic  radiation,  inductive  and/or  capacitive  coupling,  for  the 
treatment of material or inspection / analysis purpose and that it is suitable for use in all establishments other than domestic 
and those directly connected to a low voltage power supply network which supplies buildings used for domestic purposes.   

 

Statement for Class A Equipment (EN 55011, clause 5.3) 
This is a class A product. There may be potential difficulties in ensuring electromagnetic compatibility in environments other 
than industrial, due to conducted as well as radiated disturbances. 

 

Cable Specification and Equipment Orientation (EN 55011, clause 7.5.2 and EN 61000-6-2) 
Refer to the "Field wiring" section of the Installation manual. 

 

CE Marking and Apparatus Identification (2006/42/EC, clause 16.2 and 2004/108/EC, clause 8.1) 
There are printed on the nameplate of the chiller control panel. 

 

Name and Address of Manufacture 
Refer to the document of Declaration of conformity. 

 

Statement for Equipment for witch Compliance with the Protection Requirements is not ensured in Residential Areas 
(EMC Directive 2014/30/EU, clause 9.4) 
  - This product must not be used in residential areas. 
  - This product may cause interference if used in residential areas. Such use must be avoided unless the user takes 

special measures to reduce electromagnetic emissions to prevent interference to the reception of radio and television 
broadcasts. 

 

UL CERTIFICATION < for UL marking model > 

This  product  has  met  the  necessary  design  and  construction  qualifications  for  certification  per  Underwriters’ 
Laboratories. Each machine carries a UL listing and is labeled accordingly. 

 

PRODUCT PROFILE 

(1) Excellent for peak shaving during high electrical demand periods. 
(2) 

Designed to provide chilled water from waste heat sources, generated from industrial processes and 
cogeneration systems. 

(3) 

Allows diversification of critical cooling requirements. Critical cooling loads are met with minimal electrical power 
input with a hot water-fired chiller. 

(4) 

Allows for smaller generator set installation be utilized since the electrical load associated with an absorption 
chiller is minimal when compared to an electric chiller. 

(5) 

Ozone safe, CFC free. Cooling requirements are met without chlorine based refrigerants. 

(6) 

Reduces effectors to global warming. Minimizes global impact by greatly reducing electricity consumption and 
eliminating the use of greenhouse gases. 

(7) 

Environment: Molybdate solution inhibitor is used with no impact on environment. 

(8) 

Low noise and vibration. The absorption chiller dose not utilize a large motor-compressor, and this leads to quiet, 
trouble-free operation. 

(9) 

Small footprint saves facility space. 

 

USE OF PRODUCT

 

Absorption Chiller is air conditioning equipment achieving comfortable space, energy saving, and economic efficiency. 
It  has  been  used  in  office  buildings,  hotels,  department  stores,  hospitals,  schools,  convention  centers,  government 
building, etc. 

 
 

Note:    The contents of this manual are subject to change without notice.

 

 

Summary of Contents for 16LJ-F Series

Page 1: ...INSTALLATION MANUAL Absorption Chiller 16LJ F Series Original language ACQA36 00270 ...

Page 2: ...ent of Declaration of conformity Statement for Equipment for witch Compliance with the Protection Requirements is not ensured in Residential Areas EMC Directive 2014 30 EU clause 9 4 This product must not be used in residential areas This product may cause interference if used in residential areas Such use must be avoided unless the user takes special measures to reduce electromagnetic emissions t...

Page 3: ...ling work 4 2 4 Procedure and note for horizontal pulling installation 4 2 5 Installation location 4 2 6 Installation space 4 2 7 Safety precautions at the installation on the foundation 5 3 Requirements for the foundation 3 1 Foundation work 5 3 2 Accuracy of dimensions and levelness of the foundation 5 3 3 Foundation bolts 6 4 Piping 6 5 Field wiring 6 6 External visual inspection 6 ...

Page 4: ...g of the unit shall be done by the licensed professionals following the manufacturer s instructions Inappropriate operation may cause accidents such as turnover falling etc Unit shall be firmly fixed Unit shall be firmly fixed by bolts nuts on the foundation which has adequate strength to carry the system Strength poverty or fixing defect may cause a water leakage and or turnover of the unit in ca...

Page 5: ...unding works Grounding works is necessary but never connect the earth wire to the gas piping water piping and or earth line of the lightning rod or telephone Imperfect grounding may damage the unit or cause a shock Wires shall be securely connected Wires shall be securely connected and the terminal connection shall be stress free from any external force Defective connection may cause heat generati...

Page 6: ...is FOB shipping point Unloading horizontal pulling and setting are scope of supply for the purchaser 2 2 Rigging work and safety precautions 1 Only the licensee shall perform the rigging work 2 Confirm the Load and center of gravity on the specification 3 Rigging wire and shackle shall meet the local rule 4 Sling angle shall be within 60 degree 5 Four point suspension is essential Two point suspen...

Page 7: ...the unit shall be pulled ahead and behind 2 5 Installation location 1 Set the chiller on a firm and flat floor 2 The installation location should be free from corrosive gas dust and high humidity 2 6 Installation space Ensure the space based on the external dimensions in the contract specification 1 Tube removal space To enable the replacement of the all heat transfer tubes the space must be secur...

Page 8: ...oise and vibration should be taken into consideration 3 2 Accuracy of dimensions and levelness of the foundation Important precaution for the foundation dimensions are flatness of each foundation and levelness error between two foundations parted in a longitudinal direction of the chiller Permissible levelness for the absorption chiller installation The permissible levelness for the absorption chi...

Page 9: ...tage categoryⅢ And other connections shall follow the overvoltage categoryⅡ Connect each wire according to CE requiring 2 Refer to Field electric wiring and Electric wiring diagram in the contract specifications for wiring connection 3 A properly qualified electrician should carry out the electrical wiring works 6 External visual inspection The followings shall be inspected 1 Insulation for the Ch...

Page 10: ...s 4 No looseness shall be observed at each Water header flange of the chiller 5 There shall be no liquid leakage from the Chiller 6 No damage shall be observed on all components of the Chiller 7 There shall be no missing of all components of the Chiller 8 No wire cut shall be observed on electric wiring and piping ...

Page 11: ...Manufacturer CARRIER SCS Route de Thil BP49 01122 MONTLUEL CEDEX FRANCE ...