background image

38

Display symbols

Explanation of display symbols

Diastolic value

Time / Year

Systolic value

Pulse rate 
per minute

Memory sets 02

User 1 or 2

Pulse rate

Hypertension

Borderline

Normal

Hypotension

Date

Battery

Symbol

Range

Systolic

Diastolic

Hypertension

> 140 mmHg

> 90 mmHg

Borderline

130-139 mmHg

85-89 mmHg

Normal

< 129 mmHg 

< 84 mmHg

Hypotension

< 90 mmHg

< 50 mmHg

IM_HealthCont.Pro_USB_D-GB-F:IM_Temp Precise_dt-engl-ital  22.12.2009  15:34 Uhr  Seite 45

Summary of Contents for 850000

Page 1: ...guarantee Mode d emploi et garantie Deutsch Art 9320231 English Health Control Professional Fran ais Oberarm Blutdruckmess ger t Batterie Upper arm blood pressure monitor battery operated Tensiom tre...

Page 2: ......

Page 3: ...d Uhrzeit einstellen c Druckmanschette anlegen d Wichtige Hinweise vor der Blutdruckmessung e Richtige Haltung bei der Messung 06 Messungen durchf hren 19 a Ger t einschalten und automatisches Aufblas...

Page 4: ......

Page 5: ...c Putting on the pressure cuff d Important notes before measuring blood pressure e Correct posture during measurement 06 Carrying out the measurement 47 a Switching on the appliance and automatic infl...

Page 6: ......

Page 7: ...heure c Mise en place du brassard pneumatique d Avis importants pour la mesure de la tension art rielle e Comportement correct durant la mesure 06 Effectuer des mesures 75 a Mise en marche de l appar...

Page 8: ...Das Ger t ist zur Blutdruckmessung an erwachsenen Personen vorgesehen Es ersetzt keineswegs die Untersuchungen des Arztes Das Ger t ist ausschlie lich f r den privaten Gebrauch bestimmt und muss dahe...

Page 9: ...inen USB Anschluss um die Messwerte auf Ihrem PC zu speichern Die mitgelieferte Software bietet Ihnen die M glichkeit Ihre ausgewerteten Daten zu verwalten und als grafische Darstellung in unterschied...

Page 10: ...chungen des Arztes Ziehen Sie ihn immer zu Rate falls die Messergebnisse au er halb des gewohnten Bereiches liegen Bei Diabetikern Menschen mit Herzschrittmachern sowie bei Herzrhythmusst rungen Arter...

Page 11: ...rn zu messen Schalten Sie das Ger t erst ein wenn die Manschette korrekt am Arm befestigt ist Wenden Sie sich bei Defekten an unser Service Center siehe Seite 29 Dieser Artikel ist nicht daf r bestimm...

Page 12: ...chwankungen Der individuelle Blutdruck schwankt je nach Tages und Jahreszeit Er wird von verschiedenen Faktoren wie u a k rperlicher Akti vit t Angst Nervosit t etc beeinflusst Diese Schwankungen sind...

Page 13: ...ich net In der Arzt Praxis ist er recht schwierig zu messen Um ihn aber so genau wie m glich zu erfassen ist es sinnvoll die Messung zu Hause vorzunehmen Von der Welt Gesundheitsbeh rde WHO wurden fol...

Page 14: ...Mit einem Tastendruck misst es Blutdruck sowie Puls und zeigt die Messwerte zusammen mit der Uhrzeit auf einem gut lesbaren Digitaldisplay an Das Ger t kann insgesamt 100 Messungen f r einen Benutzer...

Page 15: ...Bedienelemente Messger t 9 Anschluss f r die Manschette LCD Display USB Anschluss Start Stop Taste Taste M2 Aufruf Speicher 2 Zeitstelltaste Time Taste M1 Aufruf Speicher 1 Zeitstelltaste Time Taste...

Page 16: ...hr Systolischer Blutdruck Puls pro Minute Speicherplatz 02 Benutzer 1 oder 2 Pulsanzeige Bluthochdruck Grenzwertig Normal Unter Normal Datum Batterie Symbol Bereich Systolisch Diastolisch Bluthochdruc...

Page 17: ...Deutsch 11 Zubeh r Blutdruck Messger t Arm Manschette mit Luftschlauch Aufbewahrungs Tasche CD mit Software und Bedienungsanleitung USB Kabel 4x LR6 AA 1 5 V Batterien...

Page 18: ...r verbrauchte Batterien i HINWEIS Legen Sie die neuen Batterien innerhalb von 30 Sek nach dem Herausnehmen der alten Batterien ein da sonst alle gespeicherten Daten gel scht werden i Wichtig Damit das...

Page 19: ...ng durch kurzen Druck auf die Adjust T Taste 5 Um die nderungseinstellung abzubrechen lassen Sie das Ger t ruhen ohne eine Taste zu dr cken Zehn Sekunden sp ter zeigt das Display wieder die urspr ngli...

Page 20: ...Druckmanschette nicht zu fest an Der Manschettenb gel darf nicht ber der Arterie liegen Fehlmessungen w ren die Folge Die glatte Seite der Manschette geh rt nach innen Ziehen Sie nicht am Schlauch der...

Page 21: ...schiedene Faktoren wie Rauchen Alkoholkonsum Medikamenteneinnahme und k rper liche Aktivit t beeinflusst 5 Bei Herzschrittmachern und Ver nderungen der Armvenen kann es zu Mess Ungenauigkeiten kommen...

Page 22: ...g von Arzneimitteln Durch regelm ige Benutzung des Ger ts und Aufzeichnung der Ergebnisse f r Ihren Arzt informieren Sie diesen ber anhaltende Trends Ihres Blutdrucks 10 Um die Vergleichbarkeit zu gew...

Page 23: ...ch oder auf einen anderen Gegenstand Verwenden Sie ggf eine geeignete Unterlage um den Arm so zu positionieren dass die Druckmanschette auf gleicher H he wie das Herz liegt Der Blutdruck ist je nach H...

Page 24: ...und husten Sie nicht Nehmen Sie keine Messung im Stehen vor Warten Sie bei einer Messwiederholung f nf Minuten zwischen den Messungen In dieser Zeit k nnen die gestauten Blutgef e wieder in den Norma...

Page 25: ...lle Displaysymbole Bitte berpr fen Sie ob die Anzeige mit dem Bild bereinstimmt Die Displaysymbole verschwinden nun wieder bei der Anzeige der Systole erscheint eine blinkende 0 und die Manschette wir...

Page 26: ...en der systolische Druck im oberen der diastolische Druck im mittleren und der Puls im unteren Displaybereich Diese Messwerte werden so lange angezeigt bis die Start Taste erneut gedr ckt wird Sie geh...

Page 27: ...ichen kurz auf und der Messwert wird dem Daten Speicher von Nutzer 1 oder 2 zugeordnet Wurde eine neue Messung durchgef hrt so wird der neue Mess wert im Speicherplatz 1 abgelegt und der zuvor gespeic...

Page 28: ...nuten ab e Speicherabruf Um einen fr heren Messwert abzurufen dr cken Sie die Speicher Taste M1 oder M2 Der letzte Messwert wird f r 4 Sekunden angezeigt Die Speicherplatz Nummer erscheint im Symbol B...

Page 29: ...nu ten wiederholen Ei i 2 Die Messung wurde gest rt Der Benutzer hat sich bewegt ist nicht ruhig oder hat eine unkorrekte Haltung Ruhig bleiben Messung nach 5 Minuten wieder holen Ei i 3 Druckabbau in...

Page 30: ...gung LR6 AA 4x 1 5 V Batterien Messbereich 20 280 mmHg Blutdruck 40 200 Pulsschl ge Minute Puls Genauigkeit 3 mmHg Blutruck 5 Puls Anf ngliche Druckeinstellung 180 mmHg Drucksystem Automatischer Druck...

Page 31: ...dem es direkter Sonneneinstrahlung Staub oder starker Feuchte ausgesetzt ist 3 Bewahren Sie das Ger t und die Batterien unzug nglich f r Kinder auf 4 Entnehmen Sie die Batterien wenn Sie das Ger t l n...

Page 32: ...Sie die CD ein und klicken Sie nach Erscheinen des Installations Fensters s Abb auf Install Software Folgen Sie dem Dialog auf dem Bildschirm und Schritt f r Schritt der Bedienungs anleitung 4 Nach er...

Page 33: ...schrott Es ist gesetzlich verboten Batterien in den M ll zu werfen Bitte entsorgen Sie die Batterien ber das R cknahmesystem oder einen daf r vorgesehenen Sammelbeh lter im Handel Verpackungsmateriali...

Page 34: ...EU Representative hinterlegt HINWEIS ZUR GARANTIE Bitte beachten Sie dass die Garantie bei missbr uchlicher oder unsachgem er Behandlung bei Nichtbeachtung der f r das Ger t geltenden Sicherheitsvork...

Page 35: ...versenden Sie anschlie end das defekte Ger t mit Hilfe der Wertmarke kosten frei an die unten angegebene Service Adresse Sie erhalten dann ein neues oder das reparierte Ger t kostenlos zur ck Verwend...

Page 36: ...is intended to be used for measuring the blood pres sure on adults It is not intended as a substitute for an examination by a doctor The device is intended exclusively for private use and therefore re...

Page 37: ...ail in the following This blood pressure monitoring device is equipped with a USB connection to save measured values on your PC The included software offers you the option to manage your analyzed data...

Page 38: ...ce a medical exami nation You should always consult your doctor if the measure ment results are outside the normal range With diabetics people with pacemakers and those suffering from heart rhythm dis...

Page 39: ...od pressure by means of this device with the provided cuff Switch the appliance on only if the cuff is correctly put around the upper arm Contact our Service Center see page 57 in case of defects This...

Page 40: ...in blood pressure Individual blood pressure fluctuates depending on the time of day and season It is influenced by various factors including physical activity fear nervousness etc These fluctuations a...

Page 41: ...ood pressure In practice this is very difficult to measure In order to record it as precisely as possible in this environment however it makes sense to carry out the monitoring at home The following n...

Page 42: ...on easily At the press of a button it measures your blood pressure and your pulse and shows the values measured on an easy to read digital display The appliance can save 100 measurements for one user...

Page 43: ...appliance Overview of operating elements Measurement device 37 Connection for pressure cuff LCD display On Off Start button Memory button M2 Clock set down Memory button M1 Clock set up Transmit Time...

Page 44: ...stolic value Pulse rate per minute Memory sets 02 User 1 or 2 Pulse rate Hypertension Borderline Normal Hypotension Date Battery Symbol Range Systolic Diastolic Hypertension 140 mmHg 90 mmHg Borderlin...

Page 45: ...English 39 Accessories Blood pressure monitor Blood pressure cuff with air tube Storage bag CD with software and user manual USB cable 4x LR6 AA 1 5 V batteries...

Page 46: ...empty batteries i NOTE Insert the new batteries within 30 seconds after removing the old batteries since otherwise all the saved data will be deleted i Important In order for the appliance to work pro...

Page 47: ...ed for approx 1 second when briefly pressing the Adjust T button 5 To cancel the setting leave the appliance without pressing any buttons Ten seconds later the display will show the original display a...

Page 48: ...e cuff too tightly The cuff clip should not be over the artery as this could cause incorrect measurements The smooth side of the cuff should face inwards Do not pull on the pressure cuff hose Warning...

Page 49: ...influenced by various factors such as smoking alcohol consumption the use of medicines and physical activity 5 Pacemakers and changes in the arm veins can cause the mea surement to be imprecise 6 The...

Page 50: ...and recording the results for your doctor you can inform him about ongoing tendencies shown by your blood pressure 10 To ensure comparability always carry out the measurement at the same time of day...

Page 51: ...n Place your elbow on a table or other object If necessary use a suitable base to position your arm in such a way that the pressure cuff is at the same level as your heart Your blood pressure will var...

Page 52: ...talk sneeze or cough Do not carry out any measurements when you are standing up If you are repeating the measurement wait five minutes between measurements In this time the congested blood vessels can...

Page 53: ...iance When the appliance is switched on all the display symbols appear for approx one second The display symbols disappear again during display of systolic blood pressure a blinking 0 appears The pres...

Page 54: ...f When the measurement is completed the pressure release is taking place The systolic pressure appears in the upper display area the diastolic pressure in the middle area and the pulse in the lower di...

Page 55: ...shes and the measured value is assigned to the data memory of user 1 or 2 If a new measurement was effected the new measured value is lodged into the save location 1 and the value previously saved aut...

Page 56: ...itches it off after about 3 minutes e Calling up the memory To call up an earlier measurement press the Time M1 or M2 button The last measured value is displayed for 4 seconds The save location number...

Page 57: ...g Repeat measurement after 5 minutes Ei i 2 Measurement was incorrect User has moved is not calm or has the wrong position Stay calm Repeat measurement after 5 minutes Ei i 3 Pressure decreases in cuf...

Page 58: ...Power supply LR6 AA 4x 1 5 V batteries Measurement range 20 280 mmHg pressure 40 200 beats minute pulse rate Precision 3 mmHg pressure 5 pulse Initial pressure setting 180 mmHg Pressure system Automat...

Page 59: ...4 batteries LR6 AA 1 5 V USB cable CD Special Accessories Extra large cuff circumference of approx 33 to 43 cm Please order from the Service Center see p 57 Art 9320331 9 Cleaning and storage 1 The ap...

Page 60: ...d click Install Software after the installation dialog opens see Fig Follow the steps listed on screen to install the soft ware 4 Once the software has been installed successfully on your PC you are a...

Page 61: ...allowed to throw batteries into the domestic waste Please dispose of batteries via the battery return system or using one of the spe cial collector containers provided in shops Packaging materials ar...

Page 62: ...he EU representative INFORMATION ON THE GUARANTEE Please note that incorrect or improper handling of the device failure to comply with the safety precautions that apply to the device use of force or a...

Page 63: ...receive a new appliance or get the repaired one back free of charge Parcels not prepaid cannot be accepted Please use the original packaging in order to avoid any damages in transit and enclose a copy...

Page 64: ...areil est pr vu pour la mesure de la tension art rielle de personnes adultes Son emploi ne saurait remplacer les examens m dicaux L appareil est exclusivement destin des fins domestiques et n a donc p...

Page 65: ...e d un port USB permettant de sauvegarder les r sultats sur votre ordinateur Le logiciel fourni vous permet de g rer les r sultats et de les visualiser sous forme de graphique dans diff rents diagramm...

Page 66: ...obtenir des r sultats de mesure pr cis Cet appareil ne saurait en aucun cas remplacer les examens m dicaux Veuillez toujours consulter votre m decin pour peu que les r sultats de la mesure se situent...

Page 67: ...e L appareil avec son brassard fourni n est pas appropri la mesure de la tension art rielle des enfants Ne branchez pas l appareil avant d avoir fix le brassard correctement au bras Contactez votre se...

Page 68: ...a tension art rielle individuelle varie en fonction de l heure du jour et des saisons Elle est soumise l influence de diff rents facteurs tels une activit corporelle un tat d anxi t ou nerveux etc Ces...

Page 69: ...cile prendre pour le m decin Il est donc judicieux de proc der cette mesure chez soi afin de l enregistrer avec autant de pr cision que possible dans cet environnement L Organisation mondiale de la sa...

Page 70: ...en appuyant tout simplement sur un bouton et affiche les valeurs mesur es ensemble avec l heure sur un cran num rique bien lisible L appareil peut enregistrer un total de 100 mesures pour un utili sat...

Page 71: ...5 Bouton D marrer Stopper Bouton M1 Affichage de la m moire 1 Bouton de synchronisation Bouton M2 Affichage de la m moire 2 Bouton de synchronisation Bouton T Bouton de programmation de l heure et de...

Page 72: ...systolique Pulsations par minute Emplacement de m moire 02 Utilisateur 1 ou 2 Affichage du pouls Hypertension art rielle Valeur limite Normale Inf rieur la normale Date Piles Pictogramme Plage Systol...

Page 73: ...67 Fran ais Accessoires Tensiom tre art riel Brassard avec tuyau air Pochette de rangement CD contenant logiciel et mode d emploi Cordon USB 4 piles LR6 AA 1 5 V...

Page 74: ...l espace de 30 secondes apr s avoir retir les piles us es tant donn que la m moire des donn es serait effac e au cas contraire i Important Le couvercle du compartiment piles est mettre en place fermem...

Page 75: ...la touche Adjust T 5 Laissez reposer l appareil sans l actionnement d un bouton pour interrompre le r glage des modifications L cran affiche nouveau l affichage pr c dent apr s dix secondes de m me q...

Page 76: ...u bras L trier du brassard ne doit pas se situer au dessus de l art re tant donn que ceci causerait des mesures erron es La face lisse du brassard sert de face int rieure Ne tirez pas sur le tube flex...

Page 77: ...urs comme le tabagisme la consommation d alcool la prise de m dica ments et l activit corporelle 5 Certaines impr cisions de la mesure peuvent survenir chez des sujets portant un stimulateur cardiaque...

Page 78: ...loi intervalles r guliers du tensiom tre et l enregistrement des r sultats sont des infor mations pr cieuses pour votre m decin qui lui permettent de se faire une id e des tendances de votre tension a...

Page 79: ...e table ou un autre objet Si n cessaire utilisez un support appropri pour positionner votre bras de mani re ce que le brassard se trouve la m me hauteur que le c ur La tension art rielle varie en fonc...

Page 80: ...ne toussez pas Ne demeurez pas debout durant la mesure Attendez cinq minutes entre les mesures si vous voulez les r p ter Cette dur e est n cessaire afin que les vaisseaux sanguins com prim s puissen...

Page 81: ...ant environ une seconde Veuillez contr ler la concordance de l affichage avec la figure Les pictogrammes disparaissent nouveau un 0 clignote pour l affichage de la pression systolique et le brassard e...

Page 82: ...stolique appa ra t dans le haut de l cran la pression diastolique au milieu et le pouls dans le bas Ces valeurs mesur es sont affich s jusqu au nouvel actionnement du bouton de d marrage Les valeurs d...

Page 83: ...ibu e la m moire des donn es de l utilisateur 1 ou 2 L ex cution d une nouvelle mesure a pour effet d attribuer la nouvelle valeur mesur e l emplacement de m moire 1 et la valeur enregistr e auparavan...

Page 84: ...egistr es Actionnez les boutons d enregistrement M1 ou M2 pour afficher une valeur pr alablement mesur e La derni re valeur mesur e est affich e durant 4 secondes Le num ro de l emplacement de m moire...

Page 85: ...angement de la mesure L utilisateur a boug ne s est pas tenu tranquille ou a adopt une position incorrecte Demeurez calme R p tez la mesure apr s 5 minutes Ei i 3 Chute de pression du brassard trop ra...

Page 86: ...ctrique 4 piles LR6 AA x 1 5 V Plage de mesure 20 280 mmHg tension 40 200 pulsations minute pouls Pr cision 3 mmHg tension 5 pouls R glage initial de la tension 180 mmHg Syst me de pression Mont e aut...

Page 87: ...cordon USB CD Fran ais Options brassard grande taille circonf rence de 33 43 cm commander au centre apr s vente voir page 85 Art 9320331 9 Nettoyage et stockage 1 Servez vous uniquement d un chiffon h...

Page 88: ...n7 3 Introduisez le CD dans le lecteur et cliquez sur Install Software une fois que la fen tre d installation appara t voir illustration Suivez pas pas le dialogue sur l cran et le mode d emploi 4 Une...

Page 89: ...me ferraille lectronique La Loi interdit d liminer les piles en les jetant dans les ordures m nag res Veuillez liminer les piles par le syst me de r cup ration ou les postes de collecte pr vus cet eff...

Page 90: ...spondante est d pos e chez le charg de l UE INFORMATIONS RELATIVES LA GARANTIE Veuillez noter que la garantie prend fin en cas d utilisation abusive ou incorrecte de non respect des consignes de s cur...

Page 91: ...ous vous renverrons gratuitement un appareil neuf ou votre appareil r par Des envois non suffisamment timbr s ne peuvent pas tre accept s Utilisez l emballage d origine pour viter les dommages d s au...

Page 92: ...X 49 2104 47317 Importer LUTTER PARTNER GMBH Schleissheimer Strasse 93a 85748 Garching bei M nchen GERMANY Internet http www lutter de www carrera products com Produced by YA HORNG ELECTRONIC CO LTD N...