Servicing - Inlet Valve
Helplines
5
3
4
1
2a
2b
A
A
D
C
B
A
C
B
Maintenance & Spare Parts Instructions
Wash seal to remove any dirt and inspect
for damage.
Remove seal from Cap Assembly.
Replace seal onto cap assembly.
If necessary replace cap & Seal (Spare Part
Kit 687 049)
Push & rotate to re-attach cap assembly,
re-clip Adjustment Screw and refit into
cistern.
Adjustment
Screw
To clean and inspect seal
:
unclip the Adjustment Screw, rotate & pull
to remove cap assembly.
To replace complete Inlet Valve
:
rotate nut & pull to disconnect it from the
Bracket.
Seal
Cap
Assembly
Bracket
Inlet
Valve
•
Inlet Valve is slow to fill OR fails to open ► Ensure tap is open.
•
Inlet Valve fails to close ► Clean & inspect seal as described above, replace Cap Assembly
& Seal if damaged.
•
If any other issues arise ► Consult a plumber or Caroma After Sales Service.
•
Inlet Valve Seal may require periodic cleaning (dependant on water quality).
- procedure as defined below.
Servicing Requirements
Troubleshooting Guide
•
Caroma Invisi II Inlet Valve compatible Spare Part Kits are:
687 171
Containing -
1 x Complete Unifill Inlet Valve
with bayonet connection
687 049
Containing -
1 x Cap Assembly
-
1 x Seal
Refer to -
Maintenance & Spare Parts Instructions
Spare Parts Information
Cap Assembly
Seal
Ensure mains water is turned off and
remove Inlet Valve from cistern as per the
instructions on page 17.
18