Carmanah Technologies Corp. | 250 Bay St, Victoria, BC V9A 3K5, Canada | 1.250.380.0052 |
8
APPLIED INFORMATION (AI) INTEGRATION
INSTALL GUIDE
4.2 AI 500-070 Field Control Unit (FCU)
If a second battery is installed in the upper part of the rear enclosure it will need to be removed to
fit the AI Field Control Unit (FCU). Remove the upper battery, battery bracket and battery shelf
prior to installing the FCU mounting plate.
1. Disconnect power to the system by opening all battery fuse holders or switch off the breaker (to the right).
2. Install the AI FCU mounting plate into the rear enclosure and secure with three nyloc nuts in the locations
outlined below.
3.
Drill a 17/32” hole in the top corner of the rear enclosure at the half shear location. Deburr both sides of
the hole and remove all metal chips.
4. Remove jam nut and washers from antenna. Install coax cables through previously drilled hole. Install
plastic washer, lock washer and nut as shown below. Ensure the antenna is flush with the rear enclosure
and tighten nut with a 19mm wrench.