GP-HS1500
___________________________________________________________
12
135 W
ON
ON
ON
To disable power saving, leave dip switches S1, S2, and S3
in the OFF or 0 position.
Table 3: Frequency
GP-HS1500
S4
Freq. (Hz)
0
50
1
60
5.7 What is Power Saving?
Power saving mode enables the inverter to be “on” and waiting for a load, yet draw
very little power. When power saving is enabled and the inverter senses a load, it
may take one second for the load to become active. This one-second wait will be
fine for loads that draw continually, such as televisions and stereos.
However, it may not be suitable for loads that are intermittent such as bread
makers, power tools or blenders. Power saving will continually draw a small amount
of power from the batteries, so if the inverter will not be in use for longer than a
day, it is advisable to turn the inverter off using the on/off switch located on the
front of the inverter or remote
5.8 Remotes
The GP-HS1500 is available with an optional remote (GP-SWR-B or GP-SWR-A).
The remote will turn the inverter on and off and indicate normal operation or any
faults that have caused the inverter to shut down. The remote will show battery
voltage and power consumption.
The remote will show if the battery voltage is too high and will sound an alarm if the
battery voltage falls too low (Under Voltage). The remote will also sound an alarm if
the output power is above the inverter specifications (Overload). The Under
Voltage and Overload alarm consists of five single beeps every eight seconds.