background image

21

Motor Cooling Valves & Solenoid Coils

NOTES:

1. Motor cooling valves inject liquid into the suction line.

2. Motor cooling valves require one coil of the appropriate voltage.

De-Superheating Valves

NOTE: De-superheating valves inject liquid into the economizer line or the
economizer inlet port.

PACKAGING AND STORAGE REQUIREMENTS

Packaging

Packaging for the 06Z screw compressor utilizes a wooden pallet

and shrink-wrap plastic.

Shipping

All compressors that are shipped within the U.S. or internationally

will be unstacked (single layer).

Storage

Although the 06Z compressors are painted to meet the 500 hours

salt spray requirement, it is preferable to store the compressors in-

doors where they are shielded from the weather. Outdoor storage

is permissible as long as temperatures stay within a temperature

range of 40°F to 176°F (40°C to 80°C).

Weights and Dimensions

Compressor weights and dimensions are shown in Table 27.

Table 24 — Motor Cooling Valve

PART NUMBER

COMPRESSOR USAGE

06ZC

06ZF

06ZJ

EF28BZ007 (1.4 TON)

X

X

X

Table 25 — Solenoid Coils

PART NUMBER

VOLTAGE

8BTB000295

24-1-50/60

8BTB000297

120-1-50/60

8BTB000298

208/230-1-50/60

8BTB000296

24 VDC

Table 26 — De-Superheating Valve

CARLYLE PART NUMBER

SIZE (TON)

EA680045

3

Table 27 — Basic Compressor Weight and Dimensions

(Without Electrical Box and Oil Separator)

MODEL

Weight

Dimensions

Height ‘H’

Width ‘W’

Length ‘L’

lb

kg

in.

mm

in.

mm

in.

mm

0

6ZC

1717

779

21

539

20

507

50

1259

06ZF

2199

998

23

571

21

531

56

1413

06ZJ

2893

1312

24

606

22

564

62

1584

Summary of Contents for 06ZCE1H3AA06013

Page 1: ...J Carlyle offers distinct versions of the vari able screw compressor for Medium High Temperature applica tions qualified with R 134a R 1234ze or R 513A refrigerants The following compressor features a...

Page 2: ...capacity may be varied continuously to a lower limit of 22 of the economized compressor s full load capacity for air cooled applications VI CONTROL All 06Z models are supplied with a Vi control valve...

Page 3: ...3 Fig 2 Compressor Physical Data and Connections 06ZC Frame 1...

Page 4: ...4 Fig 2 Compressor Physical Data and Connections 06ZC Frame 1 cont...

Page 5: ...5 Fig 3 Compressor Physical Data and Connections 06ZF Frame 2...

Page 6: ...6 Fig 3 Compressor Physical Data and Connections 06ZF Frame 2 cont...

Page 7: ...7 Fig 4 Compressor Physical Data and Connections 06ZJ Frame 3...

Page 8: ...ISO 220 ASSEMBLY GREASE On occasion it may be necessary to use an assembly grease to re tain an O ring within its groove The following assembly grease is approved for use with the 06Z screwcompressor...

Page 9: ...Reverse rotation is most likely to occur at initial start up or whenever the wiring to the compressor terminals is disturbed To minimize the possibility for reverse rotation operation Carlyle recommen...

Page 10: ...Module package P N 6BSB000929 which provides the follow ing safety control functionality Discharge Temperature Monitoring Oil Level Monitoring Oil Flow Rate Supply Monitoring Table 3 Control Points S...

Page 11: ...he a 500 watt flexible strip heater is recommended The heater should be wired to oper ate when the compressor is OFF This minimizes the migration of refrigerant to the oil stored in the sump Figure 6...

Page 12: ...ith the following protocol networks BACnet1 Modbus2 N2 Open LonWorks3 requires optional card RS485 Communication Port If applying the Carlyle PCM module the accessories listed in Ta ble 5 are required...

Page 13: ...13 PCM INPUTS OUTPUTS See Fig 9 for descriptions of the PCM Inputs and Outputs Fig 9 PCM Inputs and Outputs...

Page 14: ...ssor off Motor Temperature Tm will have the following functions Control a motor cooling valve to provide liquid injection to the motor compartment Turn the compressor off on an overheated motor temper...

Page 15: ...ON LED INDICATION OUTPUT 4 OUTPUT 5 COMPRESSOR MANUAL RESET REQUIRED HIGH DISCHARGE TEMPERATURE TRIP Solid red Opens De energized OFF Yes HIGH MOTOR TEMPERATURE TRIP Constant blinking Opens De energiz...

Page 16: ...ERATURE 1 Compressor must be forced to Nominal Voltage as stated in Compressor Input Voltage 2 If operating at max speed reducing speed will allow motor to run on the rated V F curve if motor temperat...

Page 17: ...17 Fig 13 Compressor Connection Details Fig 14 Sample Compressor Motor Voltage Curves...

Page 18: ...95 Hz 25 Hz 98 Hz 618 787 865 380V 3 95 Hz 25 Hz 98 Hz 325 414 455 460V 3 95 Hz 25 Hz 98 Hz 269 342 377 06ZJ 325 Hp 380V 3 95 Hz 25 Hz 98 Hz 566 720 792 460V 3 95 Hz 25 Hz 98 Hz 468 596 655 Table 13 A...

Page 19: ...of the compressor motor The thermistors are an NTC type with a standard resistance of 5000 ohms at 77 F 25 C All 06Z compressor motors are supplied with a spare thermistor to be used if the primary th...

Page 20: ...GPM 06ZC 30XV50092301 Vertical 3 125 7 06ZF 30XV50122601 Vertical 4 125 7 06ZJ 30XV80004301 Horizontal 4 50 8 Table 19 Accessory Package PART NUMBER COMPRESSOR USAGE 06ZC 06ZF 06ZJ 06ZC660001 X 06ZF66...

Page 21: ...store the compressors in doors where they are shielded from the weather Outdoor storage is permissible as long as temperatures stay within a temperature range of 40 F to 176 F 40 C to 80 C Weights an...

Page 22: ......

Page 23: ......

Page 24: ...and without incurring obligations CARLYLE COMPRESSOR DIVISION 2022 Carrier P O Box 4808 Syracuse New York 13221 Phone 1 800 532 5031 Fax 1 315 432 3274 In U S and Puerto Rico 1 800 GO CARLYLE 1 800 46...

Reviews: