BRx6 Sensor Calibration
Updated: Apr 20, 2017
Page: 8
Making sure the pole is vertical (a bipod helps) and stationary, tap the
Start Center
button. If
receiver is Fixed and within level tolerance, Sensor will collect and average 10 points with the
progress bar advancing with each point captured.
If the receiver is not level or not FIXED, the points will not be captured and a warning message
will be displayed. If points are not being captured, make the necessary adjustments as prompted
on the display. When Center Pt data capture is complete, the display will show:
If a bipod was used to steady the pole, remove the bipod or collapse the legs so the pole can
freely move in any direction. With the pole on the center point, tap the
Start Incline
button