5

SECTION 5:  

1. When replacing lamp always turn off the unit and disconnect the power

2. Remove the four screws from the lamp access plate (as shown in fig.1)

3. Remove the screws labeled D & E (as shown in fig.2)

4. Carefully remove the lamp holder

5. Remove the old / damaged lamp

6. Carefully insert the new lamp

WHEN REPLACING LAMP, DO NOT ALLOW YOUR HANDS TO COME INTO  

CONTACT WITH THE LAMP GLASS. 

      (If hands come into contact with the lamp, wipe clean with a dry cloth)

7. Replace the lamp holder with new lamp

8. Insert the screws D & E

9. Replace the lamp access plate and insert the four screws

10. Connect the power and test the new lamp

LAMP REPLACEMENT

Fig.1

Follow this direction to open cover

Be sure to disconnect unit from power before

Changing lamps or opening the unit cover.

Lamp becomes hot during operation.allow time

(at least 15 minutes)to cool before handing.do not

Look directly at lamp when lit.

Warning! 

INSIDE

POWER  SWITCH

POWER  SWITCH

ON

ON

OFF

OFF

A

B

C

D

E

Remove the lamp cover by turning screws D & E 

Turn screws A, B & C anti-clockwise  to 

reduce   the diameter of the light beam.

Turn screws A, B & C clockwise to  increase

 the   diameter of the light beam.

Turn  screw C to adjust vertical position.

Turn  screws A & B to adjust horizontal position.

Fig.2

A

B

D

E

C

Fig.3

SECTION 6:   SECURING THE FIXTURE

STANDING UPRIGHT

 

When standing upright this fixture can be permanently secured using the attachment holes 

that are in the  base of  the unit.   Please be  sure to  always position  the fixture  on a  solid 

surface that can withstand 10 times the weight of the unit.  

TRUSS HANGING 

When hanging the fixture from a truss, it is important that the truss can hold at least 10 times 

the weight of the fixture.  There are three M10 attachment holes on the base of the fixture, 

these are used to attach 2/3 clamps to secure to the truss (NOTE: ALWAYS USE TWO OR 

MORE CLAMPS).

ALWAYS USE A SAFETY CABLE WHEN HANGING FIXTURE FROM A TRUSS

Clamp

Base

www.carlosmendoza.com.mx

Summary of Contents for Showco Arc-Lite 575

Page 1: ...Showco Arc Lite 575 www carlosmendoza com mx ...

Page 2: ...TY INSTRUCTIONS Pg 3 5 LAMP REPLACEMENT Pg 5 6 SECURING THE FIXTURE Pg 5 7 POWERCONNECTIONS Pg 6 8 DMX512 CONNECTIONS Pg 6 9 CONTROLDIP SWITCH SETTINGS Pg 7 10 DMX512 MODE CHANNELASSIGNMENT Pg 9 13 ELECTRICALWIRING DIAGRAM Pg 11 15 MAINAINING AND CLEANING NOTICE Pg 13 4 11 TECNICAL SPECIFICATIONS Pg 10 12 PHOTOMETRIC DATA Pg 10 www carlosmendoza com mx ...

Page 3: ...2 SECTION 1 PRODUCT DIAGRAM FRONT VIEW 446 410 445 7 289 2 SIDE VIEW 528 VERTICAL VIEW 126 POSITION ANGLE 428 289 2 326 396 80 150 344 254 100 100 BASE www carlosmendoza com mx ...

Page 4: ...p this device away from rain and moisture Ø Unplug mains lead before opening the housing Ø Always operate the equipment as described in theuser manual Ø With a high voltage you can suffer adangerous electric shock when touching the wires Ø This device has leftour premises in absolutely perfect condition In order to maintainthis condition and to ensure safe operation it isabsolutely necessary for t...

Page 5: ...mes very hot Ø When replacing lamps and fuses always use the same type and rating as specified in this user manual CAUTION AVOID EYE DAMAGE POWERFUL LIGHT SOURCE SECTION 4 GETTING STARTED Ø DO NOT turn onthe equipmentwithout thelamp Ø Prevent shaking Avoid strong vibration whenthe equipmentis installed Ø The minimum distance from the equipment to the illuminated object must be over 2 meters and ov...

Page 6: ...directly at lamp when lit Warning INSIDE POWER SWITCH POWER SWITCH ON ON OFF OFF A B C D E Remove the lamp cover by turning screws D E Turn screws A B C anti clockwise to reduce the diameter of the light beam Turn screws A B C clockwise to increase the diameter of the light beam Turn screw C to adjust vertical position Turn screws A B to adjust horizontal position Fig 2 A B D E C Fig 3 SECTION 6 S...

Page 7: ...earth wire must always be connected during operation of this unit Ø Wiring connections should be done correctly and in accordance with the standard in your local area COMMON WIRING CONNECTIONS DMX512 CONTROLLER 120 Attention Ø The last equipment sDMX signal output mustbe connectedwith acircuit plug Ø Connect one 120 Ohm resistor to the 3 pin plug s signal and signal Connect to the last equipment s...

Page 8: ...H SETTINGS DMX512 MODE Switch 11 12 are OFF MASTER MODE Switch 11 is ON switch 12 is OFF SLAVE MODE Switch 11 is OFF switch 12 is ON When used with DMX512 the DMX ADDRESS is set using the first 10 DIP switches 1 2 3 4 1 7 13 19 1000000000 1110000000 1011000000 1100100000 LOOP ADDR BINARY USAGE OF DIP SWITCH 1 2 3 4 5 6 7 8 9 10 ON OFF 1 2 3 4 5 6 7 8 9 10 ON OFF 1 2 3 4 5 6 7 8 9 10 ON OFF 1 2 3 4...

Page 9: ...0 10sec CH 21 30sec CH 22 60sec Red Orange Green Sky Blue Light Blue Dark Blue Purple Rose Red Pink Smooth Color Change CH 23 5sec CH 24 10sec CH 25 30sec CH 26 60sec White Red Orange Green Blue Light Blue Rose Red Rapid Color Change CH 27 5sec CH 28 10sec CH 29 30sec CH 30 60sec White Red Orange Green Blue Light Blue Rose Red Smooth Color Change CH 31 5sec CH 32 10sec CH 33 30sec CH 34 60sec Whit...

Page 10: ...w Green Blue Light Blue Rose Red 10sec Smooth Color Change White Red Yellow Green Blue Light Blue Rose Red 5sec Rapid Color Change White Red Yellow Green Blue Light Blue Rose Red 60sec Rapid Color Change White Red Yellow Green Blue Light Blue Rose Red 30sec Rapid Color Change White Red Yellow Green Blue Light Blue Rose Red 10sec Rapid Color Change White Red Yellow Green Blue Light Blue Rose Red 5s...

Page 11: ...MY Color mix System CMY color mixing withspeed control DIMMER 0 100 Linear Dimmer IP 54 4 5A 230V 40 Beampath SECTION 12 PHOTOMETRIC DATA 1 1 2 2 3 3 0 2900 7200 1250 500 400 320 620 LUX 5 3 10 15 20 25 30 3 64 2 18 7 28 10 92 14 56 18 20 21 84 40 4 4 5 5 6 6 Distance m Diameter m 7 Beampath 1 1 2 2 0 8200 23000 2300 800 620 560 1200 LUX 5 3 10 15 20 25 30 0 61 0 37 1 22 1 83 2 45 3 06 3 67 7 Dist...

Reviews: