1. When replacing lamp always turn off the unit and disconnect the power
2. Remove the four screws from the lamp access plate (as shown in fig.1)
3. Remove the screws labeled D & E (as shown in fig.2)
4. Carefully remove the lamp holder
5. Remove the old / damaged lamp
6. Carefully insert the new lamp
WHEN REPLACING LAMP, DO NOT ALLOW YOUR HANDS TO COME INTO
(If hands come into contact with the lamp, wipe clean with a dry cloth)
7. Replace the lamp holder with new lamp
9. Replace the lamp access plate and insert the four screws
10. Connect the power and test the new lamp
Follow this direction to open cover
Be sure to disconnect unit from power before
Changing lamps or opening the unit cover.
Lamp becomes hot during operation.allow time
(at least 15 minutes)to cool before handing.do not
Look directly at lamp when lit.
Remove the lamp cover by turning screws D & E
Turn screws A, B & C anti-clockwise to
reduce the diameter of the light beam.
Turn screws A, B & C clockwise to increase
the diameter of the light beam.
Turn screw C to adjust vertical position.
Turn screws A & B to adjust horizontal position.
SECTION 6: SECURING THE FIXTURE
When standing upright this fixture can be permanently secured using the attachment holes
that are in the base of the unit. Please be sure to always position the fixture on a solid
surface that can withstand 10 times the weight of the unit.
When hanging the fixture from a truss, it is important that the truss can hold at least 10 times
the weight of the fixture. There are three M10 attachment holes on the base of the fixture,
these are used to attach 2/3 clamps to secure to the truss (NOTE: ALWAYS USE TWO OR