CARLO GAVAZZI NSO02D Series User Manual Download Page 12

12

the module or of the machine 

it is necessary to repeat all the 

operations listed in the TEST & 

ACTIVATION section in order to 

verify the integrity of the  

external device system .
The safety module doesn’t require 

internal maintenance: it must be 

periodically cleaned - with plant 

and module powered off - together 

with all the connected devices, 

removing dust, liquids and con-

densation .

APPLICATIONS

In the application samples when 

S1 and S2 are operated, the 

module is enabled to close the 

safety outputs (manual START) or 

closes the safety outputs (automa-

tic START) .
In Fig . 3 and 5 a dual-channel 

magnetic switch is connected to 

the input terminals . When the gate 

/ door is closed (NO contacts S1 

and S2 closed), the safety outputs 

are enabled to close . Pushing the 

START button forces the safety 

outputs to close . Opening the gate 

/ door forces the safety outputs to 

an open status .
In Fig . 4 and 6 the connections are 

the same of Fig . 3 and 5, but the 

module is configured for automatic 

START: as soon as the gate / door 

is closed (NO contacts S1, S2 

closed), the safety outputs close . 

Opening one gate / door forces the 

safety outputs to an open status .

 

Summary of Contents for NSO02D Series

Page 1: ...Manuale Utente User Manual MODULI DI SICUREZZA SAFETY MODULE NSO13D NSO02D...

Page 2: ...PPLICAZIONI 7 FIGURE E TABELLE FIGURES AND TABLES 13 DATI TECNICI TECHNICAL DATA 16 INDICE TABLE OF CONTENTS INTRODUCTION 8 FUNCTION 8 INSTALLATION 8 Warning 8 Wiring 8 Terminals coding 9 Power supply...

Page 3: ...ti nel caso in cui il dispositivo di ingres so presenti i due contatti NO aperti es con portello aperto In questa condizione il modulo di sicurezza non abilitato a chiu dere le uscite sicure ed i tele...

Page 4: ...alit di riarmo non controllato possi bile impiegare tra i morsetti S33 ed S34 modulo NSO13DB tra X1 ed X2 modulo NSO02DB un pulsante NO il cui guasto di incollaggio non viene rilevato per il riarmo ma...

Page 5: ...ura nel caso di chiusura degli ingressi a START gi premuto Inoltre un eventuale incollaggio del pulsante NO di START blocca il modulo impedendone la chiusura delle uscite sicure MESSA IN SERVIZIO Deve...

Page 6: ...pulsante NO di riarmo oppure al ponticello di cortocircuito nel caso di riar mo automatico tra i morsetti S33 S34 NSO13DB o X1 X2 NSO02DB consigliabile collegare in serie alle uscite sicure un fusibi...

Page 7: ...a chiusura delle usci te sicure In Figura 3 e 5 il collegamento del modulo prevede l impiego di un dispositivo a due canali con riarmo manuale a portello chiuso con tatti S1 S2 chiusi le uscite sicure...

Page 8: ...there are not fault conditions of the safety system the module is enabled to close the safety outputs and the external contactors can be energized released when the input NO contacts are not switched...

Page 9: ...sed The safety module is enabled to close the safety outputs only if both S1 and S2 are operated START Circuit The safety modules SA and DA are set up with not control led automatic manual START The m...

Page 10: ...he START button already pushed In the models with monitored manual START configuration if the NO START button gets wel ded the safety outputs cannot close their contacts any more TEST ACTIVATION The f...

Page 11: ...The safety module can check the integrity of external contac tors or expansion modules sim ply connecting their NC control contacts in series to the START contact or to the bridge in automatic START c...

Page 12: ...is enabled to close the safety outputs manual START or closes the safety outputs automa tic START In Fig 3 and 5 a dual channel magnetic switch is connected to the input terminals When the gate door...

Page 13: ...access monitoring Double channel NSO02D SC NSO02D DC NSO13D SC NSO13D DC NSO02D Magnetic sensor and one access monitoring Double channel NSO Dou Fig 1 Schema circuitale dei moduli NSO13D NSO13D circu...

Page 14: ...l NSO13D Magnetic sensors and two accesses monitoring Double channel NSO02D Mechanical switch and one access monitoring Single channel NSO02D Magnetic sensors and two accesses monitoring Double channe...

Page 15: ...l 13 14 23 24 33 34 NSO13DB Uscite sicure Safety outputs 41 42 NSO13DB Uscita ausiliaria NC NC auxiliary output Tab 1 Funzioni dei terminali Terminals description S21 S22 S11 S12 NSO02D SA NSO02D DA N...

Page 16: ...one Function N C pulito voltage free Caratteristiche Ratings carico resistivo resistive load 6 A 24 VAC DC 16 CARATTERISTICHE CHARACTERISTICS Tensione di alimentazione Power supply voltage 24 Vac 15 1...

Page 17: ...I A LED LED WARNINGS POWER ON OFF Alimentazione supply ON OFF CH1 CH2 ON OFF Uscite chiuse o aperte Outputs closed or open CARATTERISTICHE MECCANICHE ED AMBIENTALI MECHANICAL AND ENVIRONMENTAL CHARACT...

Page 18: ...randed or solid wire 60 or 75 C copper conductor Coppia di serraggio dei morsetti superiori ed inferiori Torque set ting on upper and lower terminals Superiori Upper Sup rieurs 0 4 0 5 Nm 4 Lb In Infe...

Page 19: ...19...

Page 20: ...O GAVAZZI si riserva il diritto di apportare modifiche o miglioramenti senza preavviso CARLO GAVAZZI reserves the right to make improvements or changes without prior notice 8021634 Mod NSO13DB24 NSO02...

Reviews: