7.1.2. Feeder section
I. A groove is to be cut from the corner of the loop to the loop detector for the feeder wire.
II. Feeder wire must be twisted all the way from that loop corner to the loop detector.
III. Minimum 20 twists per every meter.
IV. Maximum feeder wire length is 20 meters (length from loop to loop detector)
V. Feeder wire should not be in parallel with other electrical wires. Minimum distance of 10cm
between feeder wire and other wires is required.
VI. Feeder wires of different loops should also not be in close proximity with each another and feeder
wires shall not touch with other loop wires.