7. Installation & Operations

7.1. Loop and wire specification

7.1.1. Loop section

I.   Dimension of the loop is dependent on the road size and normally is rectangular in shape with 

the longest sides at right angle to the direction of the traffic.

II.    Typically, the loop should be around 2m (L) x 1m (D). However, this could be different depending 

on the actual road size. 

III.   The loop should reach maximum to within 300mm on each side to the edge of the road.

IV.   No of turns around the loop groove should follow this table:

Note: loop circumference = a+b+c+d

V.    Recommended groove depth: 30mm-40mm

VI.   Recommended groove slot width: 4-5mm

VII.  45° diagonal cut should be made to every edge in order to avoid strain on the loop wire.

 

Loop Circumference (meter)

No of turns

>10

2

6-10

3

<6

4

Summary of Contents for LDP1

Page 1: ...e and Dual Loops Plug In Carlo Gavazzi Industri Over Hadstenvej 40 8340 Hadsten Denmark Instruction manual Manuel d instructions Manuale d istruzione Betriebsanleitung Manual de instrucciones Brugerve...

Page 2: ...ENGLISH page 3 DEUTSCH seite 32 FRAN AIS page 62 ESPA OL p gina 92 ITALIANO pagina 122 DANSK side 152 182...

Page 3: ...5 2 Teach from IO Link Master 17 2 6 Sensor Specific adjustable parameters 20 2 6 1 Selection of local or remote adjustment 20 2 6 2 Process data and variables 20 2 6 3 Sensor application setting 20 2...

Page 4: ...secured against unauthorized use 1 3 Who should use this documentation This manual contains important information regarding installation and must be read and completely understood by specialized perso...

Page 5: ...andard Input Output SP Setpoints IODD I O Device Description IEC International Electrotechnical Commission NO Normally Open contact NC Normally Closed contact NPN Pull load to ground PNP Pull load to...

Page 6: ...selectable operation as pulse or presence switching Multicolor power fault LED indication for easy setup and intuitive diagnostic Individual loop state multicolor LED to indicate different loop status...

Page 7: ...ifetime 100 000 operations 5A load Protection Reverse polarity and transients Rated operational voltage UB 24 240 VAC VDC LDP1 Power consumption 24 VAC VDC 2 W 3 5 VA 115 VAC VDC 2 W 6 VA 240 VAC VDC...

Page 8: ...upply 2 Supply 3 Relay 1 N O 4 Relay 1 COM 5 Relay 2 N O 6 Relay 2 COM 7 Loop 8 Loop 9 Earth 10 Relay 2 N C 11 Relay 1 N C Earth pin must be connected to earth Do not wipe grease off pins Dual loop LD...

Page 9: ...Industri 9 EN 4 Structure Loop 2 LED Relay 2 LED Power Fault LED Reset button Loop LED Relay 1 LED Relay 2 LED Dip switch Potentiometer LDP1 Single Loop Power Fault LED Reset button Potentiometer loo...

Page 10: ...gnal indication Channel crosstalk ASB ON indication 5 LED indications In general LDP loop detectors have 3 categories of LED indications namely Power Fault indicator LED Loop state LED and Relay state...

Page 11: ...t is turned ON and everything is working well 5 2 Loop state LED Explanation 1 Green LED steady Loop inductance is within limit and working well 2 Yellow LED steady Loop inductance is too high more th...

Page 12: ...noise levels on all channels and automatically select the channel with the least noise This will be done once every time the loop detector is powered up Set DIP SWITCH 1 to ON for manual selection Us...

Page 13: ...er such as in private areas private apartments etc Note The fail safe and fail secure mentioned above is only referring to the power loss to the loop detector and not referring to the power loss of th...

Page 14: ...omatic channel selection Manual channel selection 2 Channel selection DIP switch 2 and 3 are not used in automatic channel selection 1 2 3 4 3 General settings 4 Turn on delay Delay OFF Delay 2 0 sec...

Page 15: ...7 or switch 9 the relay output can set to be activated when vehicle enters the loop or only when the vehicle exits the loop If presence mode is selected instead in switch 7 or switch 9 switch 8 and s...

Page 16: ...fic II Typically the loop should be around 2m L x 1m D However this could be different depending on the actual road size III The loop should reach maximum to within 300mm on each side to the edge of t...

Page 17: ...from that loop corner to the loop detector III Minimum 20 twists per every meter IV Maximum feeder wire length is 20 meters length from loop to loop detector V Feeder wire should not be in parallel w...

Page 18: ...and Dual Loop Detector 2018 CARLO GAVAZZI Industri 18 EN 7 1 3 Adjacent Loops I Minimum distance of 2m shall be observed between 2 adjacent loops II If dual loop LDP2 is used the loops can be install...

Page 19: ...ometry groove must be cut into the ground to install the loop This can be done by using a concrete cutting disc saw or similar device Clean the groove to make sure it is free of debris and free from m...

Page 20: ...l II Make sure that there is no object vehicle on top of the loop III Turn on the power switch to the loop detector IV The loop detector will automatically calibrate the loop inductance to optimal lev...