CARLO GAVAZZI DIS RSE Series User Manual Download Page 20

 

DISxRSE Car Park Display 

– Configuration manual 

20

 

 

Procedures 

This part describes how to connect to the display through an Ethernet connection 

 

Connect display and PC with an Ethernet cable 

If the devices you want to connect do not have access to a LAN or if the router does not have 
the DHCP server enabled, use an Ethernet cable to make a direct connection between the 
display and the PC.

 

 

 

Step 

Action 

Connect an 

Ethernet cable

 to the DISxRSE Ethernet port. 

Connect the other plug to the PC Ethernet port. 

Once they are connected, 

power 

the DISxRSE 

on

The 

display IP address

 will be shown on the screen.  

Take note of this number. 

Set a static IP address to the PC with the 

same IP class

 and 

subnet mask

 of the 

display. 
 

See the relevant procedure in this manual

 

 

 

 

 

Summary of Contents for DIS RSE Series

Page 1: ...DISxRSE CAR PARK DISPLAY USER MANUAL Mar 20...

Page 2: ...ling mounting 10 DISARSE wall mounting 11 DISBRSE ceiling mounting 12 DISBRSE wall mounting 13 DISCRSE ceiling mounting 14 DISCRSE wall mounting 15 Electrical installation 16 Things to know 16 Size th...

Page 3: ...ns 31 Digits and symbols 32 Procedures 33 Communication settings 33 Enable the display elements 34 Set the display brightness 34 Display configuration for normal parking condition 35 Display configura...

Page 4: ...DISxRSE Car Park Display Configuration manual 4 Updated version Content subject to change Download the updated version www productselection net...

Page 5: ...strictly recommend respecting these recommendations to avoid damages to devices or machinery and injury or death to people Please read this manual carefully before beginning any installation maintena...

Page 6: ...l installation The configuration procedure carried out by the integrated web based configuration software is divided into three parts Network connection Settings configuration Display settings in the...

Page 7: ...P2CPY24 controller Moreover the displays must be connected to the display interface SBP2DI48524 The displays are configurable by the integrated web based configuration software that automatically reco...

Page 8: ...software is accessible through standard browsers such as Google Chrome Mozilla Firefox or Microsoft Edge from Mobile or Desktop devices Ethernet connection An Ethernet connection is required to set u...

Page 9: ...ed with brackets that can be suitable for Ceiling mounting Wall mounting The method to install the display changes according to the model and the location The installation of the display depends on th...

Page 10: ...ounting brackets by using a 10 mm spanner 3 Overall dimensions Safety information Displays require obstruction free space for adequate air ventilation between solid mounting surfaces and top bottom su...

Page 11: ...DISxRSE Car Park Display Configuration manual 11 DISARSE wall mounting 1 Distance between the mounting brackets 2 Fix the display to the mounting brackets by using a 10 mm spanner 3 Overall dimensions...

Page 12: ...ng brackets by using a 10 mm spanner 3 Overall dimensions Safety information Displays require obstruction free space for adequate air ventilation between solid mounting surfaces and top bottom surface...

Page 13: ...DISxRSE Car Park Display Configuration manual 13 DISBRSE wall mounting 1 Distance between the mounting brackets 2 Fix the display to the mounting brackets by using a 10 mm spanner 3 Overall dimensions...

Page 14: ...rackets by using a 10 mm spanner 3 Overall dimensions Safety information Displays require obstruction free space for adequate air ventilation between solid mounting surfaces and the top and bottom sur...

Page 15: ...DISxRSE Car Park Display Configuration manual 15 DISCRSE wall mounting 1 Distance between the mounting brackets 2 Fix the display to the mounting brackets by using a 10 mm spanner 3 Overall dimensions...

Page 16: ...ical wiring related to the SBP2DI4854 interface and the power supply installation Size the power supply unit The display must be connected to a SBP2DI48524 display interface that is powered by 24 V dc...

Page 17: ...anual 17 Overview 4 Wiring diagram Element Description A 24 V dc power supply unit B 95 to 260 V ac C SBP2DI48524 display interface D DISxRSE display The maximum distance between the display and the S...

Page 18: ...ng the 4 wire cable Wire colour SBP2DI48524 terminal Black GND White A Yellow B Red 24 V Make sure the connection is correct The device will be damaged if the Voltage supply is connected to the A or B...

Page 19: ...CT CONNECTION Display and PC are directly connected with an Ethernet cable A static IP address must be assigned to the PC Display and PC must have the same IP class and the same subnet mask LAN CONNEC...

Page 20: ...the DHCP server enabled use an Ethernet cable to make a direct connection between the display and the PC Step Action 1 Connect an Ethernet cable to the DISxRSE Ethernet port 2 Connect the other plug...

Page 21: ...P address must be set according to the network parameters Step Action 1 Connect the DISxRSE to the local network 2 Connect the PC to the local network 3 Once they are connected power on the DISxRSE 4...

Page 22: ...IP address to the display Follow this procedure to set the display with a static IP address Step Action 1 Click on the Network configuration tab 2 In the IP address field type the new IP address you w...

Page 23: ...display with a dynamic IP address STEP ACTION 1 Click on the Network Configuration tab 2 Check the Enable DHCP checkbox 3 Click on the Save Configuration button to save the changes Note You are redire...

Page 24: ...ministrator who can attend you during the network configuration Step Action 1 Open Windows Control Panel by right clicking on the Start button then click on the Network and Sharing Centre icon 2 Locat...

Page 25: ...DISxRSE Car Park Display Configuration manual 25 4 Check Use the following IP address then type a Static IP see the example below 5 Click on the OK button to close the panel and save the changes...

Page 26: ...ameters The device is configured in the factory as follows If you access the Settings page for the first time use these parameters Parameter Default value Display IP address 192 168 1 201 Username adm...

Page 27: ...201 if this is the first access 2 Preview page is presented as Welcome page 3 Click on the Settings tab 4 In the Sign in popup type the username and password Note type admin admin if this is the first...

Page 28: ...r select a language by clicking the rounded flag 4 The page refreshes with the language that you selected Change the username and password To change the default credentials you must be logged in Follo...

Page 29: ...ction mode bus or API Set CPY Server Login and Password SETUP DISPLAY Indicates the model you are configuring Enables disables the display areas GENERAL SETTINGS Sets the offset number Sets the displa...

Page 30: ...ea as an element of the software Area Element Note 1 Symbol1 2 Number For the DISARSE display the maximum number of digits depends on the selected combination see Combinations for details 3 Symbol2 4...

Page 31: ...four digits One symbol on the left and one symbol on the right up to four digits One symbol up to four digits One symbol on the left or one symbol on the right up to four digits Four digits No symbols...

Page 32: ...2 options show 0 up to 4 characters i e FULL Scrolling text Tunable Seven colours available up to 100 characters Scrolling text after 10 characters Direction arrow Green The arrow can be running or s...

Page 33: ...ox choose the LAN option 2 In the IP address field type the IP address or the DynDNS of the CPY Server you are connecting 3 In the Communication port type the port that is used for SOAP API protocol d...

Page 34: ...In the Choose graphic element click on the checkbox to enable disable When an option is selected the checkbox turns blue 3 Click on the Save Configuration button to save the changes Set the display b...

Page 35: ...hapter describes the procedures to configure the elements Step Action 1 Select the elements you want to enable on the display 2 In the Display configuration Area 1 select the graphic file for Symbol 1...

Page 36: ...ed cross symbols To set the full condition see the procedure below STEP ACTION 1 Select the elements you want to enable on the display 2 In the Display configuration with full parking Area 1 Full sect...

Page 37: ...ll parking Area 4 Full section type the text In Enter message field type the text scrolling text after 14 characters From the Scrolling text field set the colour 6 Click on the Save configuration butt...

Page 38: ...t a DISxRSE display module from the Displays tab Note The selected display will be highlighted in light blue 3 Click on the Display settings button from the bar 4 In the Max value to show field set th...

Page 39: ...king bays number For instance the displays can be used to inform the drivers if a parking area is not accessible Field Description Command value Defines the Command value for each custom message Text...

Page 40: ...es follow the procedures below Part 1 Set the custom messages in the web server Access the integrated web server of the DISxRSE display then follow the procedure below STEP ACTION 1 Access the Setting...

Page 41: ...menu click on the Command display option then in the Display list select the SBP2DI48524 display interface that is connected to the display to be managed N B Choose multiple displays among those avai...

Page 42: ...ive Communication error with UWP3 0 controller SBP2CPY server Check 4 wire cable connection to the SBP2DI48524 interface Troubleshooting procedures Unplug and restart DISxRSE Sometimes rebooting the D...

Page 43: ...e configured to manage the routing between the different subnets How to check the IP address If you are not able to access the DISPLAY web server follow this procedure to check the DISxRSE IP address...

Page 44: ...orks To solve these problems out follow these steps 1 Reboot your DISxRSE Computer and verify the address 2 Check the connection from the DISxRSE Computer to the switch router 3 Set the display to obt...

Page 45: ...Enter the DISxRSE IP address and click on the Connect button Note the default IP address is 192 168 1 201 3 Click on the Load Hex File button and select the file Firmware hex 4 Click on the Erase Pro...

Page 46: ...the Choose File button and select the file WebServer bin 3 Click on the Upload button to starts the process it usually takes less than one minute When upgrade process is running do not interrupt the w...

Page 47: ...ectual property Copyright 2019 CARLO GAVAZZI Controls SpA All rights reserved in all countries CARLO GAVAZZI Controls SpA reserves the right to apply modifications or make improvements to the relative...

Reviews: