Page 12 of 16
77-3290 R1.5
New Packings Only
Run Pump for 8 hours–then tighten the packings as per the adjustment procedure
Record Data
It is important to keep written details of
pump maintenance to allow service
intervals to be developed.
Pump
maintenance
intervals
are
dependent on pump duty, pump
pressures, cycle rates and material
abrasiveness.
Adjustment Procedure
1. Turn off pump
2. Isolate & Depressurise Fluid
Section
3. Clean out Lubricant Cup if high
level of material contamination
is found
4. Undo packing nut by half a
turn (180°) to relieve pressure
on O-ring seal
5. Tighten packing nut to
120Nm
using tool 502893 and suitable
torque wrench
6. Refill Lubricant Cup with
approved Lubricant
7. Open isolation valves and
restart pump
8. Record Data i.e. date / amount
of adjustment made
Packing Seal Lubricant
Ensure the Lubricant Cup is always
at least 1/3 full
with compatible seal lubricant
(0114-016099 Water Based) (0114-016100 Solvent Based)
Daily
– Check the Pump to ensure that
there is sufficient lubricant in the
lubricant cup and that there is no
material contamination.
Weekly
– Retighten packing nut, if
required, following the adjustment
procedure – Record Data
MX440CL-SMH
INSPECTION & MAINTENANCE GUIDANCE
Summary of Contents for BINKS MX44046 Series
Page 1: ...77 3290 R1 5 www carlisleft com Instruction Manual MX44046XX XXX Pump...
Page 2: ...Page 2 of 16 77 3290 R1 5...
Page 4: ...Page 4 of 16 77 3290 R1 5...
Page 5: ...Page 5 of 16 77 3290 R1 5...
Page 6: ...Page 6 of 16 77 3290 R1 5 MX44046XX CMH MX44046XX SMH...
Page 7: ...Page 7 of 16 77 3290 R1 5 MX44046XX CMB MX44046XX SMB...
Page 9: ...Page 9 of 16 77 3290 R1 5 KEY GREASE AGMD 010 LOCTITE TORQUE...
Page 14: ...Page 14 of 16 77 3290 R1 5 DATE DETAILS OF ADJUSTMENT LUBRICATION ADDED...
Page 15: ...Page 15 of 16 77 3290 R1 5 DATE DETAILS OF ADJUSTMENT LUBRICATION ADDED...