77-3290 R1.5 

 

New Packings Only 

Run Pump for 8 hours–then tighten the packings as per the adjustment procedure 

Record Data 

 

It is important to keep written details of 
pump  maintenance  to  allow  service 
intervals to be developed. 
  
Pump 

maintenance 

intervals 

are 

dependent  on  pump  duty,  pump 
pressures,  cycle  rates  and  material 
abrasiveness.  

Adjustment Procedure 

 

1. Turn off pump 
2. Isolate & Depressurise Fluid 

Section 

3. Clean out Lubricant Cup if high 

level of material contamination 
is found 

4. Undo packing nut by half a 

turn (180°) to relieve pressure 
on O-ring seal 

5. Tighten packing nut to 

120Nm

 

using tool 502893 and suitable 
torque wrench 

6. Refill Lubricant Cup with 

approved Lubricant 

7. Open isolation valves and 

restart pump 

8. Record Data i.e. date / amount 

of adjustment made 

Packing Seal Lubricant

 

Ensure the Lubricant Cup is always 

at least 1/3 full

 with compatible seal lubricant 

(0114-016099 Water Based) (0114-016100 Solvent Based) 

Daily

 – Check the Pump to ensure that 

there is sufficient lubricant in the 

lubricant cup and that there is no 

material contamination. 

Weekly

 – Retighten packing nut, if 

required, following the adjustment 

procedure – Record Data 

MX440CL-SMH 

INSPECTION & MAINTENANCE GUIDANCE

 

Summary of Contents for BINKS MX44046 Series

Page 1: ...77 3290 R1 5 www carlisleft com Instruction Manual MX44046XX XXX Pump...

Page 2: ...Page 2 of 16 77 3290 R1 5...

Page 3: ...nlet CMH SMH Fluid Inlet CMB SMB Fluid Outlet 1 NPT Ram Inlet 1 NPT Weight 165 Pounds 81 KG Rod Upper Packing Seal Options PU PTFE UHMW PE CG Ceramic filled UHMW PE Glass filled PTFE CL Ceramic filled...

Page 4: ...Page 4 of 16 77 3290 R1 5...

Page 5: ...Page 5 of 16 77 3290 R1 5...

Page 6: ...Page 6 of 16 77 3290 R1 5 MX44046XX CMH MX44046XX SMH...

Page 7: ...Page 7 of 16 77 3290 R1 5 MX44046XX CMB MX44046XX SMB...

Page 8: ...prevent air valve freezing conditions when high cycle speeds are employed The air motor is furnished with an exhaust muffler to control air exhaust noise emission An adapter kit is also available to f...

Page 9: ...Page 9 of 16 77 3290 R1 5 KEY GREASE AGMD 010 LOCTITE TORQUE...

Page 10: ...3940 FX440 GUARD ADAPTOR 1 11 FX440XX XXX FX440XX XXX FLUID SECTION 1 Pump Accessories PART No DESCRIPTION REMARKS 192506 Exhaust Tube Adapter 1 NB hose For piped exhaust 0114 014178 Earth Wire MXA C1...

Page 11: ...804 CL Fluid Seal Kit XXB pumps Ceramic UHMW PE Leather Packing Set All O rings All Gaskets Check Main Parts List in Air Motor Fluid Section Manuals for details of individual Kit Contents Recommended...

Page 12: ...o packing nut by half a turn 180 to relieve pressure on O ring seal 5 Tighten packing nut to 120Nm using tool 502893 and suitable torque wrench 6 Refill Lubricant Cup with approved Lubricant 7 Open is...

Page 13: ...replace as required Leak from rod seal packings Gland nut not tightened after initial bedding in period a Stop the pump b Close inlet outlet ball valves c Relieve all material pressure d Clean all mat...

Page 14: ...Page 14 of 16 77 3290 R1 5 DATE DETAILS OF ADJUSTMENT LUBRICATION ADDED...

Page 15: ...Page 15 of 16 77 3290 R1 5 DATE DETAILS OF ADJUSTMENT LUBRICATION ADDED...

Page 16: ...om br Tel 55 11 5641 2776 Fax 55 11 5641 1256 WARRANTY POLICY Binks products are covered by Carlisle Fluid Technologies five year materials and workmanship limited warranty The use of any parts or acc...