EN
• Ensure all electrical and mechanical connections are correctly made.
• All required interlocks are tested and operational.
• Suitable material for pumping is available at the suction hose.
• The outlet connection is not blocked or isolated by any valves.
• Check the gearbox oil level, always adere to gearbox manufacturers recommendations on gearbox
maintenance.
Smart Mode:
The return line ‘back pressure’ regulator responds to the changes in system fluid flow demand, (due to variable
paint usage) by dynamically adjusting the paint flow rate returning to the system paint tank, thus maintaining the
set pressure.
See Smart Card manual for set up and operation in Smart mode.
Set the pump speed to the minimum frequency 20 Hz and start the pump to remove any air from the circuit.
Inspect for any system leaks.
Set the pump cycle rate to achieve the required paint volume and then adjust the system back
pressure regulator to achieve the desired system fluid pressure.
SYSTEM OPERATION
Before starting:-
77-3330 R1.3
9/36
www.carlisleft.com