ACID COMPATIBLE CCV VALVE

(COMPATIBLE WITH STRONG ACIDS SUCH AS PTSA)

Some materials and catalysts are extremely dangerous. 

Wear proper PPE during installation and maintenance. 

Consult the material SDS sheet for specific 

PPE requirements.

!

 WARNING

Know your operating pressures! Use only Binks hoses and 

fittings rated for the required operating pressures for use 

with this product. See maximum air and fluid pressure for 

each model listed in the specifications.

!

 WARNING

SPECIFICATIONS

Maximum air inlet pressure (both models):

7 bar [105 psi]

Air requirements (operating pressure):

4.8-6.9 bar [70-100 psi]

Air inlet connection port:

M5 x 0.8 (f)

Maximum fluid pressure:

69 bar [1000 psi]

Fluid connection ports (2x):

1/4" NPT (f)

Valve actuation speed (ON/OFF cycles):

55 cycles/min

Pressure Drop w/ 70 cP Test Fluid: 

(Varies w/ material press. and viscosity)

1 PSI press. drop @ 500 PSI and 200 cc/min

7 PSI press. drop @ 500 PSI and 1000 cc/min

43 PSI press. drop @ 500 PSI and 3800 cc/min

EN

SERVICE MANUAL

Summary of Contents for BINKS 240-2012-AC

Page 1: ...se with this product See maximum air and fluid pressure for each model listed in the specifications WARNING SPECIFICATIONS Maximum air inlet pressure both models 7 bar 105 psi Air requirements operati...

Page 2: ...for and on behalf of Carlisle Fluid Technologies UK Ltd Protection Level II 2 G X Ex h II Gb Solvent and Water based materials Suitable for use in hazardous area This Product is designed for use with...

Page 3: ...and Protective Systems Intended for use in Potentially Explosive Atmospheres Regulations 2016 by complying with the following statutory documents and harmonised standards BS EN ISO 12100 2010 Safety o...

Page 4: ...ASSES Failure to wear safety glasses with side shields could result in serious eye injury or blindness NEVER MODIFY THE EQUIPMENT Do not modify the equipment unless the manufacturer provides written a...

Page 5: ...PACER 1 9 240 2022 1 VALVE HEAD 1 Item No Part No Description Qty 10 SSP 1421 PIPE PLUG 1 4 1 11 CCV 13 SPANNER NUT 1 12 240 2030 SPLIT COLLAR 1 13 240 2032 SPRING CLIP 1 14 240 2047 n HOUSING SEAL 1...

Page 6: ...10 see page 1 Nm in lb or ft lb LOCTITE or equivalent MAINTENANCE SYMBOLS 7 7 8 1 Nm 68 72 in lb 2 0 2 5 Nm 18 22 in lb DISASSEMBLY ORDER SHOWN REVERSE FOR REASSEMBLY 240 2056 SEAL TOOL KIT See steps...

Page 7: ...ad of the CCV 7 Tool NOTE CCV 7 Tool Remove used o ring and install new o ring included with the valve O ring also available in 240 2011 K5 quantity pack When installing the CCV valve assembly into a...