GB / US
Supplement to the original operating instructions – Balancer
6
Supplement to the original operating
instructions
for variant type 7235 EX00 for use in potentially explosive
atmospheres
Important instructions and notes for use in environments in which an
explosive atmosphere is likely to occur (Zone 1, Zone 21)
DECLARATION OF LABELLING
II 2 / 2G Ex h IIA and Ethanol T6 Gb / Gb
II 2 / 2D Ex h IIIC T 85°C Db /Db
Gases / Vapours
Dusts
European conformity
European conformity
Explosive – designation
Explosive – designation
II
Equipment group
II
Equipment group
2 / 2G
Equipment category
2 / 2D
Equipment category
Ex h
Type of ignition protection
Ex h
Type of ignition protection
IIA and Ethanol Explosion group
IIIC
Explosion group
T6
Temperature class
85°C
Max. surface temperature
Gb / Gb
Equipment protection level
Db / Db
Equipment protection level
AREA OF APPLICATION / USE
When using the Balancer in areas with potentially explosive atmospheres, the suitability of the
unit must be taken into account in accordance with the attached designation.
With regard to the ambient temperature, a range of -20 to +40 °C is provided in accordance with
industry standard DIN EN ISO 80079-36.
INSTALLATION
When installing the Balancer, it must be earthed.
For this purpose, a marked “
“ earth connection is provided near
the suspension.