VENTION
ESPRESSO GROU
P ERROR - 9
ERROR
11:25
|
19
Febbraio 2015
131°
Error page
The waiting time of
the piston ascent has
elapsed.
Dispensing not
allowed
●
Open the upper front door
.
●
Check the position of the piston.
●
if necessary
, replace.
ESPRESSO GROU
P ERROR - 10
ERROR
11:25
|
19
Febbraio 2015
131°
Error page
The waiting time of
water
to
the
flowmeter
has elapsed.
m
issing water in the
water circuit.
●
Remove the rear panel.
●
Check the flowmeter
.
●
if necessary
, replace.
ESPRESSO GROU
P ERROR - 11
ERROR
11:25
|
19
Febbraio 2015
131°
Error page
The waiting time of
water
from
the
flow
-
meter has elapsed.
m
issing water in the
water circuit.
●
Open the upper front door
.
●
Remove the rear panel.
●
Check the flowmeter
.
●
if necessary
, replace.
ESPRESSO GROU
P ERROR - 12
ERROR
11:25
|
19
Febbraio 2015
131°
Error page
The waiting time of
waste chute opening
has elapsed.
Dispensing not
allowed
●
Open the upper and lower front door
.
●
m
echanical
fault of the grounds discharge
sys
-
tem.
Summary of Contents for BlueDot
Page 1: ...MAINTENANCE MANUAL Translation of original instructions ...
Page 2: ......
Page 5: ...3 Revision of the Manual DatE Changes 00 04 2016 First edition 01 06 2016 Chapter 2 Chapter 5 ...
Page 6: ...4 ...
Page 80: ...4 22 Align the pinion alignment guides rotating the unit clockwise Pinion Alignment guides ...
Page 112: ...5 10 1 PAUSE 2 PAUSES ...
Page 156: ...5 54 ...
Page 177: ......
Page 178: ......
Page 179: ......