2
Table of contents
1 - MECHANICAL INSTALLATION ...............................................................................................................................................3
2 - ELECTRICAL INSTALLATION ................................................................................................................................................4
2.1 - DIPS switches configuration .........................................................................................................................................4
2.2 - Commissioning ..............................................................................................................................................................4
3 - TECHNICAL CHARACTERISTICS ........................................................................................................................................5
Table des matières
1 - INSTALLATION MÉCANIQUE..................................................................................................................................................6
2 - INSTALLATION ÉLECTRIQUE.................................................................................................................................................7
2.1 - Configuration DIPS.........................................................................................................................................................7
2.2 - Mise en service..............................................................................................................................................................8
3 - CARACTÉRISTIQUES TECHNIQUES......................................................................................................................................8
SAFETY INSTRUCTIONS - PRECAUTIONS OF USE
The installation and the maintenance must be performed only by an authorized technician.
The «product » is powered by the mains. The installation must comply with the IEC 364 standard.
A readily accessible 10A max. two-pole circuit breaker must be installed in the supply line. This circuit breaker must switch off
the phase and neutral simultaneously.
The mains supply cable must be secured with a tie-wrap to prevent constraints on the terminals and to avoid possible short
circuit if a wire should come loose.
Warning: the mains cable must not be in contact with the mounting screw located right above the cable entrance. Use an
additional insulation sleeve on the L and N conductors.
See the various pictures illustrating the assembly
The product must be mounted on a wall or on a surface that must be at least 1cm wider than the product in order to limit the
access from the holes at the bottom of the casing.
CONSIGNES DE SECURITE - PRECAUTIONS D’UTILISATION
Intervention d’installation et de maintenance par une personne habilitée.
Le « produit » est raccordé à l’alimentation secteur 100-240 VAC. L’installation doit être conforme à la norme IEC 364 (NFC
15-100 pour la France).
Prévoir un disjoncteur maxi 10 A, rapidement accessible dans l’installation pour l’alimentation secteur. Le Disjoncteur doit
couper la phase et le neutre de manière simultanée.
Le câble secteur doit être fixé à l’aide du collier de façon à ne pas exercer de contraintes sur les bornes de raccordement et pour
éviter une réduction de l’isolation dans le cas ou une des bornes viendrait à se desserrer.
Attention : le câble secteur ne doit pas pouvoir toucher la vis de fixation située juste au dessus de l’entrée câble. Mettre la gaine
noire supplémentaire sur les conducteurs L et N s’ils ne sont pas gainés dans le produit.
Se reporter aux différentes photos illustrant le montage.
Le produit doit être fixé sur un mur ou une surface dépassant d’au moins 1 cm tout autour du produit pour limiter l’accès par les
trous du fond du boitier