background image

5

2.2 - Commissioning

1/ A black plastic girdle of Ø6mm is delivered in a plastic bag. Position this girdle as indicated on the photo to assure a double 
electric insulation (sector) in case the drivers L and N are not sheathed.

2/ There are 2 ways toonnect the power cord (not supplied) to the 
pc board of the Melodys Flash.
1st Method:                                  2nd method:

3/ To close Melodys Flash.fit the top of the cover 

over the back casing and apply pressure as shown 

in the illustration below.

4/ Plug the power cord into the outlet.

Powering on the Melodys Flash:

When powered up for the first time the Melodys Flash is in the INIT mode (orange «Ψ» Led flashing).
Set the Sigma master clock in the INIT mode (see the master clock user manual). Once the Melodys is initialized the «Ψ» Led 
turns red then green after the Melodys has received a DHF sounder control command from the master clock.
Nota: the DHF sounder control commands are sent every hour and every time a modification is made to the program. To set 
the Melodys Flash in the INIT mode flip the DIP switch 1 while the Melodys Flash is in operation.

    

 

 

 «Test» Button:

 

 

 

 

         - pressing this button lets you test the operation of the Melodys Flash Leds (start an  

 

 

 

           stop the test). The flashing frequency varies according to the programmed fuction  

 

 

 

          «Class» or «SEP».

    

 

 

LED «~»

 : green led indicating that the Melodys Flash is powered up.

    

 

 

LED «Ψ»

 : green/orange/red led indicating the quality of the signal between the Melodys  

 

 

 

            Flash and the master clock:

 

 

 

          - Green: communication ok.

 

 

 

          - Fixed orange: the reception is unreliable.

 

 

 

          - Flashing orange: Melodys in «Init» mode.

 

 

 

          - Red: no program received.

After being powered up the product waits for a control command from the master clock.

3 - TECHNICAL CHARACTERISTICS

The Melodys Flash complies with the EMC directives 89/336/CEE and R&TTE 1999/5/CEE (residential, commercial or 
industrial environments.
The Melodys Flash complies with the european standards:

EN 60950: safety of information technology equipment. 
EN 301-489-3 (ElectroMagnetic Compatibility (EMC) standard for radio equipment and services). 
EN 300-220-2 (Electromagnetic compatibility and Radio spectrum Matters (ERM)).

- Power supply : 100 to 240VAC ±10% 50/60 Hz.
- Consumption : 50mA in 230VAC.
- Luminosity : 60 candela/m².
- Electric insulation : class II.
- Connector of mains supply : N and L of 0,5² to 2,5².
- Entry of cables : 2x2,5² with girdle Ø10 mm maxi.
- Protection index : IP30 et IK02.
- Weight: 350 grs.
- Operating temperature: 0 to +50°C.

Cleaning:

- Use an antistatic product.
- Never use alcohol, acetone or other solvant that mau damage the casing.

Summary of Contents for Melodys Flash

Page 1: ...uit n a pas t endommag durant le transport pour r serve au transporteur Upon receipt always check the product for damage during shipment If any is found you may file a damage claim with the carrier BO...

Page 2: ...the assembly The product must be mounted on a wall or on a surface that must be at least 1cm wider than the product in order to limit the access from the holes at the bottom of the casing CONSIGNES D...

Page 3: ...over as shown on the following illustrations Attention Use the scewdriver as a lever to pry the cover open but do not push the blade more than 1 cm inside the casing so that the blade is resting on th...

Page 4: ...ity level Recommendations favor a 100 light intensity level if Melodys Flash is installed in a well lit area an a 25 level if the Melodys Flash is installed in a poorly lit area Switches 4 and 5 not u...

Page 5: ...elodys Flash Leds start an stop the test The flashing frequency varies according to the programmed fuction Class or SEP LED green led indicating that the Melodys Flash is powered up LED green orange r...

Page 6: ...vu situ sous le produit 1 2 D gager le capot en faisant levier vers le haut en prenant appui sur la platine de fixation 2 1 2 Attention ne pas enfoncer le tournevis plus de 1 cm dans la fente sous pei...

Page 7: ...ecommandations pr f rer un niveau d clairage de 100 si le Melodys Flash est expos dans une zone clair e Dans le cas contraire programmer un niveau d clairage 25 si le Melodys Flash est install dans un...

Page 8: ...t des leds du Melodys Flash lancement et arr t du mode test La fr quence de flashage diff re en fonction du mode programm Cours ou PPMS LED led verte pour indiquer la pr sence du secteur LED led verte...

Reviews: