7.2 Air/oil lubrication system
Attention: the minimal air/oil lubrication system is already tested and adjusted for cutting
of steel and cast-iron.
To activate the air-oil system put selector on upper position. The air-oil system is active only
when blade is rotating. When installing the machine, mount the air-oil system by fixing it on
the baement as shown in the picture.
Pour into oil-tank 3lt of oil:
• BECHEM Berucut MQL A20
•
IRMCO 980 103-20
•
BLASER SWISSLUBE – Vascomill 35
•
FUCHS – Plantocut micro plus 27
Connect the air entrance to “push-in” using nylon pipe of 6mm | 8mm dia.
Air pressure in entrance 5 ÷ 7 bar.
7.2.1 Oil for metal cutting
7.2.2 Pneumatic connections
The oil-distribution of the 2 pumps is
adjusted for cutting steel and cast-iron.
Act on the black cap to establish the oil-
distribution:
for cutting aluminum, brass and titanium
alloy, increase the oil-distribution turning
anti-clock-wise 1 – 2 turns the black cap.
To have a continuous and constant
lubrication is necessary to set carefully the
air output through the small brass screw
(see figure on parag. 5 on Air/Oil Manual
attached).
How to proceed for setting the Air/Oil
distribution on the blade:
7.2.3 Regulation of oil distribution
•
Disconnect the 2 black tubes Ø4 from
the red nozzle on the blade.
•
Close completely the Air output through
the brass screws.
•
Open completely the two black Oil
regulation.
•
Open slightly step by step the Air output
through the brass screws and wait
about a minute the oil pass throughout
the black tubes. In case the oil does not
come out, increase the air output.
It is suggested to do not open entirely the
Air output otherwise the Oil will not come
out.
CARIF suggest to use the air/oil Lubrication System only for cutting profiles,
tubes and solid bars of small dimensions (=< Ø 50 mm).