Technical user manual SLC
A-control
www.cargofloor.com
www.cargofloor.com
Page 18
Version 01 / July 10
th
, 2017
A-CONTROL
Control with loading / stop / unloading over a manual handle, with unique "S" detent mechanism in order
to determine loading/stop/unloading position. Non electrical.
CONTROL VALVE
Systems fitted with A-control do not include any electrical operation. The system will begin to move
depending on the position of the operation handle on the control valve. The handle should be positioned,
before and after using the Cargo Floor, in the position stop (0) if the handle is in the position 1 or 2 the
system immediately starts to move when the pump/ PTO is activated.
LOADING
– UNLOADING FUNCTION
PRECHECK
!
BE CAREFUL: when starting the pump/pto the floor could start moving immediately!
In certain configurations the functions can be different from the standard situation as described
below. It is therefore very important to always test your configuration first without a load.
After use always return the controls to the non-activated 0 position.
The position of the handle:
1
handle pushed in;
floor will unload
0
handle in the middle position;
floor stops
2
handle pulled out;
floor will load
Operating handle
Loading - Unloading
Pressure
relief valve
Threaded rod