CS 3500 

User and Installation Guide

CS 3500 

User and Installation Guide

9H4853          Ed01           2013-08

©Carestream Health, Inc., 2013.

For more information, visit:

 www.carestreamdental.com  

To give documentation feedback, visit: 

www.carestreamdental.com/documentationfeedback

Carestream Dental

A Division of Carestream Health, Inc.
150 Verona St.
Rochester, NY 14608
USA

Summary of Contents for cs 3500

Page 1: ...CS 3500 User and Installation Guide...

Page 2: ...h the furnishing performance or use of this material We recommend that you thoroughly familiarize yourself with this Guide in order to make the most effective use of your system Carestream Health is a...

Page 3: ...k 13 Arch Display 13 Preferences Dialog Boxes Overview 14 General Preferences 14 Scanner Preferences 15 Tools Preferences 17 Chapter 4 Setting Up the CS 3500 Setting Up the CS 3500 19 Testing Image Qu...

Page 4: ...Jaw 33 Scanning the Buccal Bite Registration 37 Preparation Selection 39 Check 41 Drawing Margin Lines 44 Automatically Drawing a Margin Line 44 Manually Drawing a Margin Line 46 Selecting 2D Images...

Page 5: ...indicate potential risk to personnel or equipment WARNING Warns you to avoid injury to yourself or others by following the safety instructions precisely CAUTION Alerts you to a condition that might c...

Page 6: ...2 Chapter 1 Conventions in This Guide...

Page 7: ...acquisition begins To make a manual acquisition press the acquisition button once to acquire a single image To keep the CS 3500 in manual acquisition mode deselect Auto Capture in the Preferences win...

Page 8: ...dicates the CS 3500 is active Indicates the CS 3500 is in inactive mode Indicates the power is OFF 6 USB connection indicator Indicates the connection is established Indicates the connection is discon...

Page 9: ...er Note The CS 3500 goes into inactive mode when inserted into the holder To use it again take it out of the holder Note The CS 3500 goes into inactive mode when left idle for one minute if set on a d...

Page 10: ...u should loosely coil the cable and avoid creating any sharp kinks especially in the area where the cable connects to the CS 3500 Figure 4 Correct CS 3500 Cable Storage Do not wrap the cable around th...

Page 11: ...e Carestream s imaging software is a user friendly working interface that was designed and developed as a common imaging platform for all our dental digital systems For more details see CS Imaging sof...

Page 12: ...stration Figure 6 CS 3500 Acquisition Interface Overview 1 Title Bar Displays Patient s name and type of acquisition Minimizes the Acquisition interface Maximizes or restores down the Acquisition inte...

Page 13: ...was not steady Acquisition Catalog Toolbar The acquisition catalog toolbar enables you to select the acquisition mode Lower Jaw button Acquires a 3D image of the lower jaw Upper Jaw button Acquires a...

Page 14: ...e model has been refined Edit Margin Line button Enables you to change a margin line on the model This button is available when making a restoration acquisition after the model has been refined Delete...

Page 15: ...Indicates the CS 3500 does not have a tip Overheating icon Indicates the CS 3500 is overheating If this icon is displayed place the CS 3500 in the holder for 5 to 10 minutes The CS 3500 will become in...

Page 16: ...utton Select and click OK to make an implant acquisition Click the drop down button to select Standard Abutment or Custom Abutment Import button Select and click OK to access the folder from which you...

Page 17: ...Orthodontic Preparation Check A list of items you must check on the orthodontic 3D model to verify the accuracy of the model before sending it to the imaging software You must examine the appropriate...

Page 18: ...enables you to select these options Language Select the menu language Help Language Select the online help system language Hole Filling Color Select the color used to highlight the filled holes after...

Page 19: ...older Click to navigate to the folder to which you want to save the CSZ file Open File Location Click to open the folder containing the CSZ files Scanner Preferences Figure 8 Scanner Preferences The S...

Page 20: ...acquiring your next image by helping to ensure the correct amount of overlap with each image A green indicator means you can proceed with the acquisition an orange indicator means there is not enough...

Page 21: ...to select these options Create Support File Click to select the folder where the log files for service information are saved Diagnose Scanner After attaching the service calibration diagnostic tip cl...

Page 22: ...18 Chapter 3 CS 3500 Software Overview...

Page 23: ...the CS 3500 Installation Wizard flash drive into the USB drive The AutoPlay window is displayed 3 Select Run wizard exe The Autorun window is displayed 4 Select a language from the drop down list sel...

Page 24: ...into an outlet 8 Connect the USB cable to the computer 9 Press the power button one second to power on the CS 3500 Ensure the power indicator turns orange 10 Wait until the USB connection indicator t...

Page 25: ...software or open the imaging software from within your practice management software 3 Find or create the patient record 4 Double click the patient record to access the imaging window or tab 5 In the i...

Page 26: ...B 5 Place the taped side of the CS 3500 holder on the clean surface C and press firmly several times for correct adherence The maximum adherence is obtained after two hours A B x2 C Important You must...

Page 27: ...wall mount holder follow these steps 1 Select an area that you can access easily 2 Insert screws through the appropriate holes in the holder to affix it to a solid surface x2 x2 Important If the holde...

Page 28: ...24 Chapter 4 Setting Up the CS 3500...

Page 29: ...e Acquisition Interface Using the Imaging Software To access the CS 3500 Acquisition interface from the CS Imaging software the CS Orthodontic Imaging software or the CS OMS Imaging software follow th...

Page 30: ...e CS 3500 To set up the preferences follow these steps 1 On the Acquisition interface click The Preferences dialog box is displayed 2 Click to set the general preferences 3 Click to set the CS 3500 pr...

Page 31: ...the acquisition an orange indicator means there is not enough overlap or the angle of the CS 3500 is incorrect Capture Beep When the capture beep is enabled the CS 3500 beeps each time a scan is atte...

Page 32: ...tion Important Scanning Procedures Orthodontic Acquisition Scanning One Surface at a Time Start with the occlusal surface and scan the teeth on the jaw Next scan the lingual surface of the teeth and s...

Page 33: ...ss until you have scanned all the teeth in the implant area as well as the surrounding teeth on the jaw Finally acquire the buccal bite registration Scanning Metal Crowns or Holes When scanning metal...

Page 34: ...S 3500 as illustrated with the lens facing downward A for a lower jaw view or upward B for an upper jaw view Important The removable scanner tip is autoclavable up to 20 cycles After 20 cycles discard...

Page 35: ...collar when scanning the anterior teeth Slide the collar onto the CS 3500 tip as illustrated Scan the anterior teeth and remove the collar to scan the remaining teeth Always disinfect the body of the...

Page 36: ...32 Chapter 5 Getting Started...

Page 37: ...n check and export the image Scanning Teeth on the Upper and Lower Jaw To acquire images using auto acquisition follow these steps 1 Dry the teeth thoroughly before starting an acquisition 2 Access th...

Page 38: ...he tip on the tooth surface to steady the CS 3500 Live video is displayed on the video preview screen When the CS 3500 is stable and the image is clear the acquisition begins Images are automatically...

Page 39: ...ing teeth in the preparation area keeping approximately a 30 overlap with the last image 7 When the occlusal surface scan is complete scan the lingual surface of the teeth in the preparation area Hold...

Page 40: ...e lower jaw Click and repeat steps 5 through 8 until the teeth in the area of restoration on the lower jaw are scanned The example below shows a 3D model of the lower jaw when the occlusal lingual and...

Page 41: ...Position the CS 3500 at a 90 degree angle to the buccal surface of the preparation area and align the point where the upper and lower teeth meet in the middle of the video preview screen Rest the tip...

Page 42: ...uire additional bite images which will increase the accuracy of the bite 4 Acquire at least two more buccal bite images one on either side of the preparation area You can take up to six bite images fo...

Page 43: ...fic teeth on the 3D model for refinement follow these steps 1 Click to perform preparation selection 2 Click 3 Place the cursor over the area you want to refine and left click and drag the mouse to se...

Page 44: ...to angle the image and select teeth from above not from the side This prevents teeth behind the target teeth from being refined Important You cannot select more than half an arch or you will not be a...

Page 45: ...e 3D model to move it in the window Left click and hold on the 3D model to rotate it If your mouse has a scroll wheel use the wheel to zoom in or zoom out on the 3D model Click to scale the model to i...

Page 46: ...lower jaw 8 If you are exporting the 3D model to a dental lab you can draw a margin line reference on the 3D model See Drawing Margin Lines 9 Click The Preparation Check window is displayed 10 Examine...

Page 47: ...the margin line is acceptable click the corresponding option in the Preparation Check window If the margin line is not acceptable click Cancel Click and re scan the affected teeth 13 When satisfied w...

Page 48: ...lly draw the margin line Automatically Drawing a Margin Line To automatically draw a margin line follow these steps 1 Click The Margin Line Tools are displayed on the toolbar 2 Click 3 Click on the pr...

Page 49: ...he following To edit the margin line click on the margin line to select it Click Redraw the section of the margin line you want to alter and be sure it connects with the existing margin line To delete...

Page 50: ...ng a Margin Line You must manually draw the margin line if the case involves an inlay or onlay To manually draw a margin line follow these steps 1 Click The Margin Line Tools are displayed on the tool...

Page 51: ...the 3D model and do any of the following To edit the margin line click on the margin line to select it Click Redraw the section of the margin line you want to alter and be sure it connects with the e...

Page 52: ...nipulate the 3D model to the position you want to view 3 Click on the areas of the 3D model for which you want 2D images The images are displayed on the Views tab 4 Click the checkmark on the upper ri...

Page 53: ...res Scan the upper and lower jaw Scan the buccal bite registration Refine the image Complete the preparation check and export the image Scanning Teeth on the Upper and Lower Jaw To acquire images usin...

Page 54: ...p on the tooth surface to steady the CS 3500 Live video is displayed on the video preview screen When the CS 3500 is stable and the image is clear the acquisition begins Images are automatically acqui...

Page 55: ...h the last image 7 When the occlusal surface scan is complete scan the lingual surface of the teeth Hold the CS 3500 at a 45 degree angle to the lingual surface of the teeth Be sure to include several...

Page 56: ...n scanned you can begin scanning the lower jaw Click and repeat steps 5 through 8 until the teeth on the lower jaw are scanned The example below shows a 3D model of the lower jaw when the occlusal lin...

Page 57: ...low these steps 1 Click 2 Have the patient bite down 3 Position the CS 3500 at a 90 degree angle to the buccal surface of the teeth and align the point where the upper and lower teeth meet in the midd...

Page 58: ...displayed in the Acquisition interface the bite image is successful and you can acquire additional bite images which will increase the accuracy of the bite 4 Acquire several additional buccal bite ima...

Page 59: ...e registrations 6 When you have finished acquiring the buccal bite registration proceed to the check step Check The check step enables you to further process the 3D image to obtain the highest accurac...

Page 60: ...our mouse has a scroll wheel use the wheel to zoom in or zoom out on the 3D model Click to scale the model to its best view Click or to hide the upper or lower jaw Click the button again to restore th...

Page 61: ...remove the boundaries using the tool 8 Examine the 3D model for irregular soft tissue and do one of the following If there is no irregular soft tissue in the image click the corresponding option in t...

Page 62: ...del to the position you want to view 3 Click on the areas of the 3D model for which you want 2D images The images are displayed on the Views tab 4 Click the checkmark on the upper right corner of an i...

Page 63: ...tandard Abutment Use when an abutment is present in the jaw The acquisition process is the same as the restoration acquisition process Custom Abutment Use when acquiring 3D models to be sent to a lab...

Page 64: ...t the Upper Jaw acquisition mode OR On the CS 3500 press the mode button for one second to select the acquisition mode The mode indicator LED turns green 5 Hold the CS 3500 at a 90 degree angle to the...

Page 65: ...occlusal surface to scan the remaining teeth in the implant area keeping approximately a 30 overlap with the last image 7 When the occlusal surface scan is complete scan the lingual surface of the te...

Page 66: ...e anyway Click Yes Continue with the steps listed under Using the Free Cut Tool to Cut Out the Implant Area on page 66 OR You can begin scanning the lower jaw Click and repeat steps 5 through 8 until...

Page 67: ...ition Scanning the Buccal Bite Registration To acquire a buccal bite registration using auto acquisition follow these steps 1 Click 2 Have the patient bite down 3 Position the CS 3500 at a 90 degree a...

Page 68: ...essful bite image includes both the upper and lower arch Half of a dot only one arch upper or lower indicates a partial buccal bite The example below shows that one complete buccal bite image and one...

Page 69: ...d zoom the view to ensure that the bite is accurate and that there are no areas where the bite is mismatched Click a dot to view the bite for that acquisition The example below shows several buccal bi...

Page 70: ...ote If you selected the Enable Refinement Check option in the Preferences window the software will refine the image before you perform the cutting step If you are satisfied with the refined image clic...

Page 71: ...9H4853 _Ed07 67 3 Double click the mouse 4 When you have finished cutting out the implant area continue with the scan body acquisition Note If you removed too much of the image click to restore the i...

Page 72: ...can body in position follow these steps 1 Install the scan body 2 Click 3 Re scan the jaw concentrating on the area containing the scan body Repeat the steps for acquiring an image as described in Sca...

Page 73: ...image 2 Manipulate both images in the split screen view at the same time using the following methods Right click and hold on a 3D model to move both models in the window Left click and hold on a 3D m...

Page 74: ...image without the scan body or with the scan body Click to select and delete excess soft tissue in the image 3 If you find holes in the implant area click and re scan the teeth that are missing data 4...

Page 75: ...necessary adjustments to the implant area and then re scan the implant area and surrounding teeth 8 Examine the gum tissue surrounding the implant in the 3D model and do one of the following If all of...

Page 76: ...When satisfied with the 3D model click to send the 3D model to the imaging software Important To view your 3D models use the CS Mesh Viewer that was installed on your desktop For instructions on using...

Page 77: ...del to the position you want to view 3 Click on the areas of the 3D model for which you want 2D images The images are displayed on the Views tab 4 Click the checkmark on the upper right corner of an i...

Page 78: ...74 Chapter 8 Acquiring a 3D Model for Implants...

Page 79: ...infect and sterilize the CS 3500 and accessories regularly The removable CS 3500 scanner tips and collars are autoclavable up to 20 cycles After 20 cycles discard the tip and collar Important For info...

Page 80: ...76 Chapter 9 Maintenance...

Page 81: ...tative in the European Community Carestream Health France 1 rue Galil e 93192 Noisy Le Grand Cedex France Importer for European Union Carestream Health Netherlands B V Bramenberg 12 3755 BZ Eemnes The...

Page 82: ...Carestream Health Inc 2016 For more information visit www carestreamdental com To give documentation feedback visit www carestreamdental com documentationfeedback Carestream Dental A Division of Care...

Reviews: