35
ENG
Maintenance
WTS LARGE +0300131IT rel. 1.0 - 05.09.2022
Replace the pre-filter cartridge:
»
Every 2 months if the free chlorine content is between 0.1 ppm and 0.2 ppm.
»
Every 4 months if the free chlorine content is less than 0.1 ppm.
Notice:
The lifetime of the pre-filter and membrane(s) depends on feed water quality and permeate production rate.
Notice:
Maximum permitted storage times of the membranes:
• 6 months: if the membranes are already supplied with a chemical solution and/or impregnated with glycol;
• 1 year: if the membranes are supplied dry or vacuum packed.
9.5.4 Maintenance by qualified per- sonnel
Every 6 months:
Check the pre-filling pressure of the expan- sion vessel. This value must be 1.5 to 1.8 bar. To check the pressure, the
outlet line of the vessel must be temporarily interrupted.
Generally:
»
Check the parameters of the water entering the system.
»
Check the conductivity of the input water and permeate with a conductivity meter.
»
Record the data for the listed tests
Maintenance schedule
Min. Every 2/4 months
Every 12 months
As needed
Unit / spare part
Sediment filter
Carbon filter
Uv lamp
Membrane (s)
O-ring
Number
ROL160
ROKC00FLT3
ROKC00FLT2
ROKL00UVL1 /
ROKC00UVOR
ROKL00ME10
ROKL00OR25
2
ROL320
4
ROL460
ROKL00FLT4
ROKL00FLT5
ROKL00ME20
ROKL00ME40
2
ROL600
ROKL00ME30
ROL1000
ROKL00UVL2 /
ROKC00UVOR
ROKL00ME20
4
ROL1200
ROKL00ME30
Summary of Contents for Large ROL 160-1K2
Page 2: ......
Page 6: ......
Page 43: ...43 ENG Control WTS LARGE 0300131IT rel 1 0 05 09 2022...
Page 59: ...59 ENG Spare parts WTS LARGE 0300131IT rel 1 0 05 09 2022 20 21 22 23 24 25 26 27 28 29 30...
Page 65: ...Notes...
Page 66: ...Notes...
Page 67: ......