10. Spare parts 

 

 

Storlek  

Top part Olivia   Top part CuroCell LF  CuroCell Comfort fabric  Bottom part CuroCell 

80x200 cm 

CC-906911 

CC-916210  

CC-907411  

CC-905511 

80x210 cm  

CC-906912 

CC-916211  

CC-907412  

CC-905512 

85x200 cm 

CC-906913  

CC-916212 

CC-907413  

CC-905513 

85x210 cm  

CC-906914  

CC-916213  

CC-907410  

90x200 cm  

CC-906916  

CC-916214  

CC-907415  

CC-905616 

90x210 cm  

CC-906917  

CC-916215  

CC-907416  

CC-905617 

105x200 cm  CC-906910  

CC-916216  

CC-907430  

CC-905510 

120x200 cm  CC-906920  

CC-916218  

CC-907440  

CC-905521 

 

Art.no.  

Name 

Size

 

CC-901310 

Cell, PU 

80x21 cm 

CC-901311 

Cell, PU 

85x21 cm 

CC-901312 

Cell, PU 

90x21 cm 

CC-901313 

Cell, PU 

105x21 cm 

CC-901314 

Cell, PU 

120x21 cm 

Please make a note on your order when ordering ventilating cells. 

 

CC-901330 

Heel cell, PU 

80x21 cm 

CC-901331 

Heel cell, PU 

85x21 cm 

CC-901332 

Heel cell, PU 

90x21 cm 

CC-901333 

Heel cell, PU  105x21 cm 

CC-901334 

Heel cell, PU  120x21 cm 

 

CC-8217  

Fuse (set of 2) 

CC-8201 

Filter, washable 

 

If other spare parts are needed, please contact Care of Sweden or your local dealer for further 

assistance. 

 

 

Summary of Contents for CuroCell 4

Page 1: ...User manual 2019 04 26 CuroCell 4 Alternating pressure system Item number user manual 95 001044...

Page 2: ...roduction 4 Product description 6 Assembly Installation 8 Operation 9 Cleaning and reconditioning 11 Storage 12 Maintenance 13 Troubleshooting 14 Technical description 15 Spare parts 17 Options and ac...

Page 3: ...pump power cord or plug is defective the pump casing is damaged or it is not functioning properly Contact a service technician for examination and repair 6 Regularly check product functionality throug...

Page 4: ...ing them immediately to us here at Care of Sweden The system has been tested and approved according to the following standards IEC 600601 1 IEC 60601 1 2 SS EN ISO 12182 SS EN ISO 14971 SS EN ISO 1099...

Page 5: ...u can order a copy from our Customer services by sending your details to info careofsweden se NOTE For certain patients such as amputees are the recommended minimum weight not valid These users may ho...

Page 6: ...on 2 1 Pump and mattress 1 CPR rapid deflation a Head b Foot 2 Pump 3 Mattress 4 Pump connector 1a Tubing system with CPR in head 1b Tubing system with CPR in foot With the optional heel section is th...

Page 7: ...t care repositioning transferring in and out of bed Turn off this function by pressing the button It will return automatically to cycling after approx 30 minutes 5 Low pressure LOW PRESSURE The pump h...

Page 8: ...d correctly 2 Hang the pump at the foot end of the bed or place it on a flat steady surface Route the power cord so that there is no risk of it causing someone to trip being run over by the bed wheels...

Page 9: ...prescriber or other authorized personnel for appropriate setting 1 Use the comfort dial to set a suitable air pressure based on the settings table on the pump 2 When the green indicator lamp for norm...

Page 10: ...til the pressure is corrected and reset See section 8 for troubleshooting 4 5 CPR In the event of an emergency requiring CPR cardiopulmonary resuscitation Quickly pull the CPR strap remove the quick c...

Page 11: ...alcohol with or without tensides Isopropanol 70 oxidating solutions or chlorine max 1 If using a different agent choose one that does not affect the pump housing MATTRESS COVER Covers can be wiped of...

Page 12: ...tubes and the CPR valve with a mild cleaning solution for this purpose such as alcohol with or without tensides Isopropanol 70 oxidating solutions or chlorine max 1 Let it dry 5 Wipe off and disinfect...

Page 13: ...parts 7 2 Changing fuses 1 Pull the plug out of the electrical socket before replacing fuses 2 Remove the cover for the fuses with a screwdriver Pull out the fuse holder 3 Fit a new fuse of the same t...

Page 14: ...ew minutes Do a hand check Refer to section 4 3 Check that the CPR valve valves are properly closed Mattress moves around Check that the air mattress is fastened to the bed frame with the straps under...

Page 15: ...35 C Storage 15 C 50 C Shipping 15 C 70 C Humidity Operation 20 80 non condensing Storage 10 90 non condensing Atmospheric pressure 700hPa 1060hPa Classification Class II Type BF IP21 MATTRESS SPECIFI...

Page 16: ...ycling Read the user manual Machine wash at 70 C CE marked acc to MDD 93 42 EEC Machine wash at 95 C Directly on bed base Tumble dry Do not iron Recommended user weight Patient information category Wi...

Page 17: ...10 CC 916216 CC 907430 CC 905510 120x200 cm CC 906920 CC 916218 CC 907440 CC 905521 Art no Name Size CC 901310 Cell PU 80x21 cm CC 901311 Cell PU 85x21 cm CC 901312 Cell PU 90x21 cm CC 901313 Cell PU...

Page 18: ...els of the bed NOTE This option is only available with new orders Sheet holder Specialised clips to which the sheet can be attached Six required per mattress 11 2 Accessories Art no Description and si...

Page 19: ...t be submitted to Care of Sweden before the product is returned Please contact Care of Sweden or your local dealer if you have questions regarding warranty and service 12 3 Life expectance This produc...

Page 20: ...ternet www careofsweden com Address Care of Sweden AB P O Box 146 SE 514 23 Tranemo SWEDEN Visit address Fabriksgatan 5A SE 514 33 Tranemo SWEDEN Cargo address Byns v g 4A SE 514 33 Tranemo SWEDEN Sup...

Reviews: