background image

CCM3A-2216-EU-PIR-MKX

MOVEMENT MONITOR 11/12/13

USE MAINS POWER SUPPLY

PS3A-2207-UK ONLY

SILENT ALERT SA3000 SYSTEM

WWW.SILENTALERT.IE Silent Alert International

TEL +353 (0)1 247 9007

MOVE KEY D

OWN 

TO SWIT

CH ON

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

  1 = System Co

de 1

  2= System

 Code 2

  3 = System Co

de 3

  4 = System Co

de 4

  5 = 

Audio

 Monitor

ing

  6 = Zone Multipl

ier (7

-12)

  7 = Short 

Audio

 Delay

  8 = Medium

 Audi

o Delay

  7 & 8 = Long 

Audio

 Delay

  9 = PIR Delay 5 Mins

10 = PIR Delay 10

 Mins

9 & 10 = PIR Dela

y 15 m

ins

11 = Zone 6

12 = Zone 5

13 = Zone 4

14 = Zone 3

15 = Zone 2

16 = Zone 1

MOVE KEY D

OWN 

TO SWIT

CH ON

1.

To change the zone you need

 to reset the monitor: 

Remove the battery,  

press the push button, 

replace the battery.

Changing the Zone

The unit will by default cause zone 1 on the pager or signwave to light. 

PUSH

Press and release the 

test button whilst the 

light is green. The light 

will  flash red once, 

twice then three times 

and so on up 

to twelve. 

3.

PUSH

To set the zone 

number, briefly press 

the test button at the 

desired number of 

flashes.

The indicator light will 
flash green to confirm 

the selection.  

4.

 The monitor will then 

perform the battery voltage 

level display and start as 

normal. Press the test button 

to confirm the correct zone 

has been selected. 

PUSH

5.

PUSH

After the flashing red/

green startup 

sequence the light will 

shine constant green.

2.

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

Changing the system channel code

NOTE.

 In most cases it is not necessary to change the system code. However, when one or 

more systems are in close proximity, system codes can be used to avoid interference from 
other Care Call systems using up to a maximum of 16 channels. 

The monitor is supplied with no 

system code switches set (system code 1). 

For reference this is the factory setting 

should you need to re-set the unit.

System codes can be set using 

key switches 1 - 4. 

The diagram to the right shows the 16 

possible combinations.

KEY 7 MUST BE LEFT ON!

Be sure that the same system code is set on 

the receiver to be used and any other 

monitoring options in that system.

2

3

4

5

6

7

8

1

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

9

1 2 3 4 5 6 7 8

10

1 2 3 4 5 6 7 8

12

1 2 3 4 5 6 7 8

11

1 2 3 4 5 6 7 8

13

1 2 3 4 5 6 7 8

14

1 2 3 4 5 6 7 8

15

1 2 3 4 5 6 7 8

16

1 2 3 4 5 6 7 8

Movement return delays

It is possible to add a non-return delay to enable a period of time to pass from the sensor detecting movement to the 
monitor sending a signal. This can be useful to allow a user get a drink or visit the bathroom without triggering the system. 

Move key 5 across to 

the right

A count down timer will start. If the 

person returns within the time period the 

monitor will disarm and reset. 

Now, instead of triggering instantly the 

monitor will display it has detected 

movement by flashing the status 

light red.

1.

2.

PUSH

VI

IX

III

5 MINUTES

1 2 3 4 5 6 7 8

Key 5 

5 minutes

Key 6 

10 minutes

If the monitor doesn't detect 

movement in the allotted time it 

will send a signal to the 

Pager or SignWave.

The timer is configurable as shown.

3.

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

Keys 5 & 6 

15 minutes

1 2 3 4 5 6 7 8

Advanced settings CCC4A-2212-EU

Care Call Mini Chair Leaving Monitor

Care

Call

Any questions? Call us on

+353 (0)1 247 9007

Reviews: