CCM3A-2216-EU-PIR-MKX
MOVEMENT MONITOR 11/12/13
USE MAINS POWER SUPPLY
PS3A-2207-UK ONLY
SILENT ALERT SA3000 SYSTEM
WWW.SILENTALERT.IE Silent Alert International
TEL +353 (0)1 247 9007
MOVE KEY D
OWN
TO SWIT
CH ON
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1 = System Co
de 1
2= System
Code 2
3 = System Co
de 3
4 = System Co
de 4
5 =
Audio
Monitor
ing
6 = Zone Multipl
ier (7
-12)
7 = Short
Audio
Delay
8 = Medium
Audi
o Delay
7 & 8 = Long
Audio
Delay
9 = PIR Delay 5 Mins
10 = PIR Delay 10
Mins
9 & 10 = PIR Dela
y 15 m
ins
11 = Zone 6
12 = Zone 5
13 = Zone 4
14 = Zone 3
15 = Zone 2
16 = Zone 1
MOVE KEY D
OWN
TO SWIT
CH ON
1.
To change the zone you need
to reset the monitor:
Remove the battery,
press the push button,
replace the battery.
Changing the Zone
The unit will by default cause zone 1 on the pager or signwave to light.
PUSH
Press and release the
test button whilst the
light is green. The light
will flash red once,
twice then three times
and so on up
to twelve.
3.
PUSH
To set the zone
number, briefly press
the test button at the
desired number of
flashes.
The indicator light will
flash green to confirm
the selection.
4.
The monitor will then
perform the battery voltage
level display and start as
normal. Press the test button
to confirm the correct zone
has been selected.
PUSH
5.
PUSH
After the flashing red/
green startup
sequence the light will
shine constant green.
2.
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Changing the system channel code
NOTE.
In most cases it is not necessary to change the system code. However, when one or
more systems are in close proximity, system codes can be used to avoid interference from
other Care Call systems using up to a maximum of 16 channels.
The monitor is supplied with no
system code switches set (system code 1).
For reference this is the factory setting
should you need to re-set the unit.
System codes can be set using
key switches 1 - 4.
The diagram to the right shows the 16
possible combinations.
KEY 7 MUST BE LEFT ON!
Be sure that the same system code is set on
the receiver to be used and any other
monitoring options in that system.
2
3
4
5
6
7
8
1
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
9
1 2 3 4 5 6 7 8
10
1 2 3 4 5 6 7 8
12
1 2 3 4 5 6 7 8
11
1 2 3 4 5 6 7 8
13
1 2 3 4 5 6 7 8
14
1 2 3 4 5 6 7 8
15
1 2 3 4 5 6 7 8
16
1 2 3 4 5 6 7 8
Movement return delays
It is possible to add a non-return delay to enable a period of time to pass from the sensor detecting movement to the
monitor sending a signal. This can be useful to allow a user get a drink or visit the bathroom without triggering the system.
Move key 5 across to
the right
A count down timer will start. If the
person returns within the time period the
monitor will disarm and reset.
Now, instead of triggering instantly the
monitor will display it has detected
movement by flashing the status
light red.
1.
2.
PUSH
VI
IX
III
5 MINUTES
1 2 3 4 5 6 7 8
Key 5
=
5 minutes
Key 6
=
10 minutes
If the monitor doesn't detect
movement in the allotted time it
will send a signal to the
Pager or SignWave.
The timer is configurable as shown.
3.
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Keys 5 & 6
=
15 minutes
1 2 3 4 5 6 7 8
Advanced settings CCC4A-2212-EU
Care Call Mini Chair Leaving Monitor
Care
Call
Any questions? Call us on
+353 (0)1 247 9007