8527-0544-2M Rev G
APS Enterprise Scale
13
SETUP AND CONFIGURATION, CONT.
PORt3
(POS Serial Port 3 – OPOS Compatible)
This is the third serial port output format selection. The default format for this port is NCI in
order to work with most POS systems that require NCI format.
The serial port parameters for this port are fixed at 9600 baud, 7 data bits, 1 stop bit and
Even parity for any output format selected EXCEPT the UPS WorldShip output format.
NOTE:
When UPS WorldShip output format is selected for POS Serial Port 3, the serial
port parameters are set to 4800 baud, 7 data bits, 1 stop bit and Even parity.
Press the
UNITS
key to show current setting. If value displayed is acceptable, press the
UNITS
key again to save it. Otherwise, press the
ZERO
key to step through selections for
a new value and then press the
UNITS
key to save it.
Options for
PORT3
output format are as follows:
SnnA
This selection allows the port to respond to the following commands and
will output Weight on Demand in the appropriate format.
Cardinal ENQ (hex 05)
Detecto AS-410D ~ (tilde, hex 7E), Pounds ONLY Mode
SMA (W)
nci
NCI output format
nntps
Mettler Toledo PS output format
nntsi
Mettler Toledo SICS output format
LPL
Lone Peak Labeling
UPS
UPS WorldShip output format
IMPORTANT! Selecting
LPL
(Lone Peak Labeling) for the port output
format will change the behavior of the scale. When the scale settles on
“any” positive weight above zero, the display will lock on that weight until
the scale returns to zero.
Usb
(USB Port)
The USB port output format selections are similar to the serial port settings. When
connected to a PC, this should appear as a virtual com port and can transmit weight using
any of the formats listed below.
Press the
UNITS
key to show current setting. If value displayed is acceptable, press the
UNITS
key again to save it. Otherwise, press the
ZERO
key to step through selections for
a new value and then press the
UNITS
key to save it.
Options for
USB
port output format are as follows:
SnnA
This selection allows the port to respond to the following commands and
will output Weight on Demand in the appropriate format.
Cardinal ENQ (hex 05)
Detecto AS-410D ~ (tilde, hex 7E), Pounds ONLY Mode
SMA (W)
nci
NCI output format
nntps
Mettler Toledo PS output format
nntsi
Mettler Toledo SICS output format
LPL
Lone Peak Labeling
IMPORTANT! Selecting
LPL
(Lone Peak Labeling) for the port output
format will change the behavior of the scale. When the scale settles on
“any” positive weight above zero, the display will lock on that weight until