Cardinal 6127 Series Operating Instructions Manual Download Page 16

8525-M310-O1 Rev E 

 612X Series and 633X Series 

12 

PARTS IDENTIFICATION 

FINAL ASSEMBLY 

 

ITEM

 

QTY PART 

NUMBER

 

DESCRIPTION

 

1 1 

3P1201X-1 

BASE 

ASSEMBLY 

430XG3R800 

COLUMN ASSEMBLY FOR 6127(KG), 6129(KG) 

 

0044-C180-1A 

COLUMN ASSEMBLY FOR 6337, 6339 

709GR1206 

LOAD CELL ASSY 

0033-B254-08 

DRAFT ROD FOR 6127(KG), 6129(KG) 

 

0033-B256-08 

DRAFT ROD FOR 6337, 6339 

5 1 

3P8068 

PLATFORM 

COVER 

6 4 

63K1038  BASE 

LEG 

6650-0087 

LABEL, MADE IN USA 

8 1 

0033-B438-0A 

MOUNTING 

BRKT 

391RV204 

NUT ELASTIC STOP 1/4-20 Z/P 

10 

6021-1454 

SCW HEX HEAD 1/4 -20 X 3/4 

11 1 

6024-0004 WASHER 

FLAT 

1/4 

12 1 

0033-B104-0A 

TOP 

PLATE 

ASSY. 

13 1 

593R986  SERIAL 

TAG 

14 

6024-0049 

WASHER LOCK EXT #10 

15 

6024-0047 

WASHER LOCK EXT 1/4 

16 

6021-1423 

SCW TRUSS HEAD 1/4-20 X 1/2 

17 

6021-1045 

SCW HEX HEAD #10-32 X 1/2 Z/P 

18 1 

750 

DIG. 

WT. 

INDICATOR 

19* 

0033-D203-0A 

HEIGHT ROD ASSEMBLY, INCH/CM FOR 6129(KG) 

20* 

0033-D475-0A 

HEIGHT ROD ASSEMBLY, 1/4”/1mm FOR 6129KGM 

21* 

0033-D063-1A 

HEIGHT ROD ASSEMBLY, INCH/CM FOR 6339 

22* 

6800-1045 

OPTIONAL AC ADAPTER 100-240VAC/12VDC @ 1A 

*

 NOT SHOWN 

Summary of Contents for 6127 Series

Page 1: ...6127 Series 6129 Series and Eye Level Scale Models 6337 and 6339 Operating Instructions CARDINAL SCALE MFG CO 8525 M310 O1 Rev E PO BOX 151 WEBB CITY MO 64870 Printed in USA 06 15 PH 417 673 4631 FAX...

Page 2: ...8525 M310 O1 Rev E 612X Series and 633X Series 2...

Page 3: ...cordance with the local laws regarding the disposal of waste electrical and electronic equipment It is everyone s responsibility to help maintain the environment and to reduce the effects of hazardous...

Page 4: ...8525 M310 O1 Rev E 612X Series and 633X Series 4II This page intentionally left blank...

Page 5: ...city 550 lb x 2 lb 250 kg x 1 kg selectable 550 lb x 2 lb 250 kg x 1 kg selectable Platform Size 10 5 8 x 14 1 2 270 mm x 368 mm 10 5 8 x 14 1 2 270 mm x 368 mm Dimensions 10 7 8 W x 20 7 8 D x 37 7 8...

Page 6: ...ashers securing the indicator bracket to the column 4 Lower load cell and draft rod assembly into column Draft Rod must pass through opening in column bracket Referring to Figure No 1 make sure open e...

Page 7: ...633X Series 3 ASSEMBLY INSTRUCTIONS CONT Figure No 3 Figure No 2 Figure No 4 Column Bracket Opening Raise Draft Rod Push Lever Draft Rod Grommet Load Cell Cable C 10 32 Truss Head Screw Lock Washer In...

Page 8: ...howing zero weight on the display press ZERO key 2 Weight display will return to zero ZERO STABLE and lb or kg annunciators will turn on to show a stable center of zero weight condition Metric Convers...

Page 9: ...Press or keys until desired height in inches is displayed and then press or key to move the blinking character to FEET b Press or keys until desired height in feet is displayed c Proceed to Step 7 6...

Page 10: ...drilled please follow installation instructions Height Rod Installation 1 Remove the height rod height rod brackets and hardware pack from the cardboard insert 2 Attach the height rod brackets to the...

Page 11: ...e slotted holes in the height rod brackets over the four hex head screws on the back of the column 4 Pull down to set the screws in the small end of the slotted hole and secure the bracket to the colu...

Page 12: ...horizontally on top of patient s head 4 Read height of patient as follows If back of spoon points to outer height rod then it points to correct height If back of spoon points to inner height rod then...

Page 13: ...rod 2 If not already installed insert the two hex head screws from the hardware pack into holes in front of column and tighten them with included wrench until hex heads are 1 8 from column 3 Place bo...

Page 14: ...until the spoon rests horizontally upon the top of the person s head 4 Read the height of the person as follows If back of spoon points to outer height rod then it points to correct height If back of...

Page 15: ...s Power Up Zero or Zero Weight Display CALib Indicates calibration is necessary AdErr ErrAL ErrAH Consult your scale service representative OCAP Scale weight exceeds scale capacity OFF Displayed to in...

Page 16: ...E IN USA 8 1 0033 B438 0A MOUNTING BRKT 9 1 391RV204 NUT ELASTIC STOP 1 4 20 Z P 10 1 6021 1454 SCW HEX HEAD 1 4 20 X 3 4 11 1 6024 0004 WASHER FLAT 1 4 12 1 0033 B104 0A TOP PLATE ASSY 13 1 593R986 S...

Page 17: ...4 3P2087 PLATFORM LOAD BEARING 3 1 3P1001X BASE WELDMENT 4 2 3P60 CHECK PLATE 5 2 6021 0985 HEX WASHER HD SCW 10 X 1 2 6 4 63K1038 BASE LEG 7 1 2U58 UNION CENTER HANGER 8 1 3P8003X SHORT LEVER ASSEMBL...

Page 18: ...ng for the freight both ways This warranty does not apply to peripheral equipment not manufactured by Detecto this equipment will be covered by certain manufacturer s warranty only This warranty does...

Page 19: ...nnection with the sale or use of the product Detecto will not be liable for consequential damages of any nature including but not limited to loss of profit delays or expenses whether based on tort or...

Page 20: ...8525 M310 O1 Rev E 612X Series and 633X Series 16...

Reviews: