9
Container installation procedure
• Remove the screws
"B"
and carefully extract
the P.C.B. card
"C"
from the container re-
membering to store it somewhere safe from
dust and possible damage.
• Using the container as a template mark the
four points at which the fastening holes are to
be drilled;
• Fasten the container using four screws and
raw plugs
"G"
and insert the screw covering
plugs
"H"
.
• Insert the pipe fittings "
D
"
(fig. 4A) and check
that they are fastened correctly.
• Re-insert the electronic card into the con-
tainer and fasten down using the screws
"B"
(fig.4A)
• Insert the rigid electrical connection pipes
"I"
into the cable tubes. The
230V~/400V3
power
cables should be passed through pipes 1 and
2 (see figure) so as to separate them from the
low voltage wires which should be passed
through pipes 3 and 4.
• Carry out the electrical connection following
the attached wiring diagram (see fig. 5).
PRG
2-04-98
DM0138
Description :
Product Code :
Date :
Drawing number :
P.j.Heath
CARDIN ELETTRONICA S.p.A
- 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
Draft :
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
Inserimento scheda PRG383
D
A
E
C
B
LPRG
2-04-98
DM0135
Description :
Product Code :
Date :
Drawing number :
P.j.Heath
CARDIN ELETTRONICA S.p.A
- 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
Draft :
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
Installazione contenitore PRG
F
G
H
160 MM
130 MM
PRG
2-04-98
DM0139
Description :
Product Code :
Date :
Drawing number :
P.j.Heath
CARDIN ELETTRONICA S.p.A
- 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
Draft :
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
Inserimento pressatubi PRG383
4
3
2
1
I
4A
4
4B
4C
4