background image

10 

Part number 3E1100 R16 

 

July 2010 

 

Approvals and Standards 

FCC 

This equipment has been tested and found to comply with the limits for a Class B digital 
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference in a residential installation. This 
equipment generates, uses and can radiate radio frequency energy and, if not installed 
and used in accordance with the instructions, may cause harmful interference to radio 
communications. However, there is no guarantee that interference will not occur in a 
particular installation. 

If this equipment does cause harmful interference to radio or television reception, which 
can be determined by turning the equipment off and on, the user is encouraged to try to 
correct the interference by one or more of the following measures: 

 

Reorient or relocate the receiving antenna. 

 

Increase the separation between the equipment and receiver. 

 

Connect the equipment into an outlet on a circuit different from that to which the 
receiver is connected. 

 

Consult the dealer or an experienced radio/TV technician for help. 

Note: 

Changes or modifications not expressly approved by Gallagher Group Limited 

could void the user's authority to operate the equipment. 

 

For UL Installations:

 

Refer to the section in the Cardax FT Command Centre Installation Note, 

"Configuration Instructions to meet Underwriters Laboratory Inc Approved 
Installations"

 for details covering specific requirements necessary to meet the specified 

UL Licences.  The following Release Note version(s) contain these details: 
vEL5.21.xxx  May 2009  
vEL6.01.xxx October 

2009 

Installers must ensure these instructions are followed to ensure the installed system is 
UL compliant. 
UL temperature range tested and certified from -35

0

C - +66

0

C . 

The voltage current values used and measured during testing are shown in the table 
“Voltage / Current measurements” included in the Cardax FT Command Centre 
Installation Note, 

"Configuration Instructions to meet Underwriters Laboratory Inc 

Approved Installations"

.

 

 

Summary of Contents for Prox Mifare Series

Page 1: ...ferent lengths WARNING You must use the screws provided as using other types of screws could interfere with the electronics See the Mounting section later for further explanation Firmware Version vMT3...

Page 2: ...ort tail of this cable is supplied with connector fitted with each reader When using a single cable to carry both power supply and data from the source to the reader both the power supply voltage drop...

Page 3: ...than 200mm away Mounting Note The Prox Mifare Series Teardrop reader has been designed to metric specifications Therefore any imperial measurements provided are approximate only The Prox Mifare Series...

Page 4: ...lding cabling through the base and grommet Fit the base to the 20 mm 3 4 inch hole and secure it to the mounting surface using two of the fixing screws provided Note The surface the reader is being at...

Page 5: ...he inside surface of the reader base Install the PCB assembly into the base Fit the facia onto the base by clipping the small lip inside the facia over the top edge of the base and holding the top pre...

Page 6: ...00 4R Cardax FT Controller 3000 Use the cable terminating tool to connect the cables to the socket as described in the following sections Pin number 4 of the Prox Mifare Series Teardrop reader connect...

Page 7: ...4 on the Controller 3000 Each group provides connection for two Prox Mifare Series Teardrop readers or other Cardax IV readers Refer to the following diagram for the location of the ports on the Carda...

Page 8: ...egand Readers This is because connecting one Wiegand reader requires all four pins on plug PB For example if you connect a Prox Mifare Series Teardrop reader to Port 1 of Group 1 Port 2 of Group 1 can...

Page 9: ...a Cardax IV reader within the Cardax FT Command Centre system Initialising with the Cardax FT Controller 3000 4R or 3000 Refer to the appropriate Installation Note for initialization instructions Card...

Page 10: ...equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Note C...

Page 11: ...re Series Teardrop reader should only be cleaned with clean lint free damp cloth Power required Voltage 13 6 15 V DC Current 125mA Reading range Up to 30mm depending on card type and installation cond...

Page 12: ...12 Part number 3E1100 R16 July 2010 Mounting Dimensions 17 mm 39 mm 51 mm 51 mm 20 mm Pilot hole Pilot hole 20 mm hole Slot...