B-18 OPERATION B-18
CUTTING IN CUT MODE
1 Put the Cutting torch and cable quick connect plug into the electrode output receptacle. Turn clockwise until
tight. Connect the work clamp to the work piece.
2 Set the TIG/STICK/CUT switch to "cut".
.
OPERATING NOTES:
1. For safest operation, be sure 2T is selected. Do not attempt to use the foot pedal to control the amps.
2. Do not attempt to use the plasma torch in any other mode or test in any other mode with torch connected.
3. Attempt to operate only with sufficient air pressure. If pressure is too low, the unit will cease output and the green
indicator light next to the pressure gauge will go out to indicate the air pressure is too low to operate safely.
4. See torch manual included in this manual for best pressure settings and parts identification.
5. Do not exceed 90 psi air supply pressure from compressor or failure or leakage of internal line components may result.
6. Do not use with an oiler or with an air line that has had oil run through the line.
7. Adjust torch operation pressure to 72 psi (5 bar) for best results while post flow is flowing.
8. When using lower amperage levels, the nozzles will need to be changed out for ones with a smaller diameter orifice.