B-5 OPERATION B-5
9. nameplate
T
he data plate stamped on the metal structure
complies with the EN 60974-1,
EN50199(EN60974-10) international standards and
contains the following information:
* (a) Manufacturer's name and address
* (b) Trademark
* (c) Model
* (No) Serial number
* ( ) The welding power
source comprises a frequency converter followed by
an transformer and rectifier that transforms input
voltage into direct current.
* (EN 60974-1/EN 50199) Standards applied.
* ( ) Direct current.
* (x) Utilisation factor expressed as a percentage of
useful work over a cycle of 10 minutes at an
ambient temperature of 40
o
C.
* (I
2
) Rated weld current.
* (U
2
) Conventional load voltage.
* (Uo) Rated no-load voltage.
* ( ) CUT welding.
* ( )) 1input phases.
* (IP21S) Casing protection degree in compliance
with the EN 60529 Standard:
IP2XX Casing protected against access to
dangerous components with fingers and against the
introduction of foreign matters with diameter 12.5
mm.
IPX3X Casing protected against rain failing at
60~on the vertical line.
IPXXC Casing protected against contact of a test
gauge
φ
2.5 mm length 100 mm with live
dangerous parts,
* (U
1
) Rated power supply voltage.
* (50/60 Hz) Power supply rated frequency.
* (l
lmax
) Maximum supply current.
(I
1 eff
) Effective supply current.* ( S ) Generator
suitable for installation in places where major risks
of electric shocks are preset
* (CE) In compliance with the European regulations
in force.
10. air pressure-reduced valve
11. pressure air entrance 12. fan
13. indication of air pressure-reduced valve
14. grounding column 15. input cable
10. air pressure-reduced valve
The regulator assembly serves as both a filter/water
trap, and an air regulator. The water trap with the
fine sediment filter is self draining. It is not designed
to dry the air, but rather serves the purpose of
catching any residual slug of water that may be
present in the air line and filtering any trash or
sediment that passes into the bowl of the regulator.
It is not designed to serve as an air dryer. A
separate air dryer must be placed between the
regulator and the air compressor.During the
assembly of the regulator, be sure to screw the 1/4”
automotive quick connect into the side that is
stamped on top with “IN” or that has been stamped
with an arrow pointing to the center of the regulator.
The small brass plug should screw into the center of
the regulator and the remaining push-to-connect
fitting should be screwed into the remaining hole.
Then, connect the clear tubing to the push-to-
connect. Make sure the shoulder of the tubing has
been cut squarely or the connection may leak as a
result. Screw the regulator bracket to the back of
the plasma cutter first before attaching the regulator
to the bracket. Make sure the screws located in the
accessory bag are the proper length and are
inserted with the accompanying lock and flat
washers. To adjust the regulator, simply pull the
knob up slightly until it clicks, and rotate the knob
clockwise to increase the pressure or counter
clockwise to decrease the pressure. To lock in the
setting, push the knob down until it clicks. Do not
exceed 90 psi supply pressure. Do not exceed 85
psi on the plasma cutter side of the regulator or
internal leakage may result. Operating air pressure
should be set between 70 and 75 psi while in to
“Test” mode.
11. pressure air entrance
The gas input line is connected to the Regulator
assembly via the clear tubing provided in the
accessory package. To attach, simply push the
tubing into the connector until it is firmly seated then
give a slight tug to make sure it has been captured
correctly by the fitting. Make sure that the tubing
shoulder is squarely cut and not cut at an angle. An
uneven or angular cut will cause leaking at the
connector. If the tubing must be removed, simply
push on the outer plastic collar back while holding
the tubing firmly in the other hand.
12. fan
when power switch on, the cooling fan runs
~
Summary of Contents for DIGI-CUT70
Page 22: ...B 8 OPERATION B 8...
Page 23: ...B 9 OPERATION B 9...
Page 24: ...B 10 OPERATION B 10...
Page 25: ...B 11 OPERATION B 11...