CARBONE DIGI-CUT70 Operator'S Manual Download Page 19

   

B-5                                OPERATION                                      B-5 
 

9. nameplate 

T

he data plate stamped on the metal structure 

complies with the EN 60974-1, 
EN50199(EN60974-10) international standards and 
contains the following information: 
* (a) Manufacturer's name and address 
* (b) Trademark 
* (c) Model 
* (No) Serial number 
 
*  (                                                  )  The  welding  power 
source comprises a frequency converter followed by 
an transformer and rectifier that transforms input 
voltage into direct current. 
* (EN 60974-1/EN 50199) Standards applied. 
* (                ) Direct current. 
* (x) Utilisation factor expressed as a percentage of 
useful work over a cycle of 10 minutes at an 
ambient temperature of 40

o

C. 

* (I

2

) Rated weld current. 

* (U

2

) Conventional load voltage. 

* (Uo) Rated no-load voltage. 
 
* (                ) CUT welding. 
 
 
* (            )) 1input phases. 
 
* (IP21S) Casing protection degree in compliance 
with the EN 60529 Standard: 
 

IP2XX Casing protected against access to 

dangerous components with fingers and against the 
introduction of foreign matters with diameter 12.5 
mm. 
 IPX3X Casing protected against rain failing at 
60~on the vertical line. 
 IPXXC Casing protected against contact of a test 
gauge 

φ

2.5 mm length 100 mm with live 

dangerous parts, 
* (U

1

) Rated power supply voltage. 

* (50/60 Hz) Power supply rated frequency. 
* (l

lmax

) Maximum supply current. 

 (I

1 eff

) Effective supply current.* ( S  ) Generator 

suitable for installation in places where major risks 
of electric shocks are preset 
* (CE) In compliance with the European regulations 
in force. 
10. air pressure-reduced valve   
11. pressure air entrance 12. fan     
13. indication of air pressure-reduced valve 
14. grounding column 15.    input cable 
 

10. air pressure-reduced valve   

The regulator assembly serves as both a filter/water 
trap, and an air regulator. The water trap with the 

fine sediment filter is self draining. It is not designed 
to dry the air, but rather serves the purpose of 
catching any residual slug of water that may be 
present in the air line and filtering any trash or 
sediment that passes into the bowl of the regulator. 
It is not designed to serve as an air dryer. A 
separate air dryer must be placed between the 
regulator and the air compressor.During the 
assembly of the regulator, be sure to screw the 1/4” 
automotive quick connect into the side that is 
stamped on top with “IN” or that has been stamped 
with an arrow pointing to the center of the regulator. 
The small brass plug should screw into the center of 
the regulator and the remaining push-to-connect 
fitting should be screwed into the remaining hole. 
Then, connect the clear tubing to the push-to- 
connect. Make sure the shoulder of the tubing has 
been cut squarely or the connection may leak as a 
result. Screw the regulator bracket to the back of 
the plasma cutter first before attaching the regulator 
to the bracket. Make sure the screws located in the 
accessory bag are the proper length and are 
inserted with the accompanying lock and flat 
washers. To adjust the regulator, simply pull the 
knob up slightly until it clicks, and rotate the knob 
clockwise to increase the pressure or counter 
clockwise to decrease the pressure. To lock in the 
setting, push the knob down until it clicks. Do not 
exceed 90 psi supply pressure. Do not exceed 85 
psi on the plasma cutter side of the regulator or 
internal leakage may result. Operating air pressure 
should be set between 70 and 75 psi while in to 
“Test” mode. 

 
11. pressure air entrance   

The gas input line is connected to the Regulator 
assembly via the clear tubing provided in the 
accessory package. To attach, simply push the 
tubing into the connector until it is firmly seated then 
give a slight tug to make sure it has been captured 
correctly by the fitting. Make sure that the tubing 
shoulder is squarely cut and not cut at an angle. An 
uneven or angular cut will cause leaking at the 
connector. If the tubing must be removed, simply 
push on the outer plastic collar back while holding 
the tubing firmly in the other hand. 

 
12. fan   

when power switch on, the cooling fan runs 

 

 
 
 

Summary of Contents for DIGI-CUT70

Page 1: ...MACHINE Suitable for 1x220V Operators s Manual Safety Setup and General Use Guide REV 2 0 00145 16 Issue Date May 12 2016 Manual No 0 1535 EMPRESAS CARBONE S A Calle 5ta Rio Abajo Panam Panam Telefon...

Page 2: ...erformance Should you have an issue or question concerning your unit please contact performance technical support available through the main company headquarters available in your country For best ser...

Page 3: ...________ Where Purchased _____________________________ Whenever you request replacement parts or information on this equipment please always supply information you have recorded above This product is...

Page 4: ...e information please contact our Support The warranty does not cover improper use maintenance or consumables Do not attempt to alter or defeat any piece or part of your unit particularly any safety de...

Page 5: ...tection is available exclude them from the work area Even brief expo sure to the rays from the welding arc can damage unprotected eyes Always wear hearing protection because welding and cutting can be...

Page 6: ...s nose or throat are signs that you need to increase ventilation Stop immediately and relocate work if necessary until adequate ventilation is ob tained Stop work completely and seek medical help if i...

Page 7: ...materials including rags and spare clothing away from area Keep all flammable fuels and liquids stored separately from work area Visually inspect work area when job is completed for the slightest trac...

Page 8: ...llation Engine Driven Generator A 5 Output Connections A 6 Work Cable Connection A 6 Operation Section B Safety precautions B 1 Product Description B 2 Cutting Capability B 2 Control Panel B 4 Cutting...

Page 9: ...ple 70A 60 for CUT MODEL DIGI CUT70 CNC Power Voltage 1 x 220 V 10 50 60Hz Fuse rating 60A Input Current 58A Rated Output Current 70A Current Adjusting Range 20 70A No load Voltage 250V Rated Duty Cyc...

Page 10: ...Use a Super Lag type fuse or circuit breaker with a delay in tripping action Models with NEMA 6 50P plug may be used with a 50 amp protected 6 50R receptacle or with a maximum 70 amp protected 6 50R...

Page 11: ...of the equipment Never make the cargo pass or leave it suspended over people or things Neither let the equipment or the single unit fall nor put it down with force Once it has been removed from the p...

Page 12: ...to an earth ground close to the work clamp using one of the following methods a A metal underground water pipe in direct contact with the earth for ten feet or more b A 3 4 19mm galvanized pipe or a 5...

Page 13: ...or defeat the purpose of the power cord ground pin RECONNECT PROCEDURE The Inverter machine auto reconnects to either 115V or 230V supply Fuse the input circuit with time delay fuses or delay type1 ci...

Page 14: ...y of the engine drivenpower supply The following are recommended outputcurrent settings when used with various Lincolnengine driven power supplies CONNECTIONS FOR CUTTING WORK CABLE CONNECTION Next co...

Page 15: ...der electrically hazardous conditions such as welding in wet areas or on or in the workpiece FUMES AND GASES can be dangerous Keep your head out of fumes Use ventilation or exhaust at the arc or both...

Page 16: ...ct with water spray The unit is rated IP21S which rates it for light contact with dripping water It is a good idea to remove the welder from the vicinity of any water or moisture source to reduce the...

Page 17: ...E The expected life for the DIGI CUT70 s electrode under normal conditions is approximately 30 to 40 minutes ofcutting time at the machine s maximum rated output An erosion of approximately 1 16 in th...

Page 18: ...on the machine With the air flowing adjust the air pressure flow up or down until the ball is floating in the sight window of the flow tube If no flow tube is present or provided with your unit then...

Page 19: ...filtering any trash or sediment that passes into the bowl of the regulator It is not designed to serve as an air dryer A separate air dryer must be placed between the regulator and the air compressor...

Page 20: ...ght does not go off and cutting is still prevented the cycle the machine off and then back on 18 indication of PSI OK TO CUT minimum Air Pressure OK to Cut LED This light should remain on as long as t...

Page 21: ...l cease output and the green indicator light next to the pressure gauge will go out to indicate the air pressure is too low to operate safely 3 See torch manual included in this manual for best pressu...

Page 22: ...B 8 OPERATION B 8...

Page 23: ...B 9 OPERATION B 9...

Page 24: ...B 10 OPERATION B 10...

Page 25: ...B 11 OPERATION B 11...

Page 26: ...s to take place To avoid receiving a high frequency shock keep the TIG torch and cables in good condition ROUTINE AND PERIODIC MAINTENANCE 1 Disconnect power supply lines to machine before performing...

Page 27: ...This column describes possible symptoms that the machine may exhibit Find the listing that best describes the symptom that the machine is exhibiting Step 2 POSSIBLE CAUSE The second column labeled PO...

Page 28: ...2 Maintenance in manufacturer or service center Output current decreased 1 Input voltage too low 2 Input line is too thin 2 Power line is thickened Current can not be regulated 1 connecting line of th...

Page 29: ...1 NOTE This diagram is for reference only It may not be accurate for all machines covered by this manual If the diagram is illegible write to the Service Department for a replacement Give the equipme...

Page 30: ...ing a jumper on the CNC circuit board to create either 1 16 th or 1 50th of the raw arc voltage It may be used by some controllers for torch height control THC Usually the 1 16 setting is preferred Pi...

Page 31: ...s 1 Certificate of quality 1 Air pressure Regulator 1 Output cable 1 No Certificate of quality Name of product DC INVERTER AIR PLASMA CUTTING MACHINE Type of product DIGI CUT70 CNC Packing No Test res...

Page 32: ...electrically live parts or electrode with skin or wet clothing Insulate yourself from work and ground No toque las partes o los electrodos bajo carga con la piel o ropa moja da Aislese del trabajo y...

Page 33: ...e Be und Entl ftung des Arbeitsplatzes Mantenha seu rosto da fuma a Use ventila o e exhaust o para remover fumo da zona respirat ria Turn power off before servicing Desconectar el cable de ali mentaci...

Reviews: