16
NOT_CARBEST-00
NOT_CARBEST-00
UK
12V 20A
input
Voltage
230V +/- 15% - 115V on request
Frequency
50Hz - 60Hz (+/- 10%)
Cos phi
0.6 typ
Efficiency
80% typ
Consumption
3A
Fuse
T4A 250V 5x20mm
Output
Nb of output
1 output
Nb charginig curves
5 possible charging curves.
Selection by external dip-switch
Curves types
IUUo & automatic weekly equalization
Charging
profiles
Voltage Allowance
+/- 2%
Ripple
< 1% pp (BW < 20 MHz)
Current
20A
Fuse
F25A 32V
Automotive
Protections
Against output overload, output short circuit,
excessive internal temperature, excessive
battery temperature, output overvoltage,
battery reverse polarity (fuse)
general
Display
Tricoloured LED
Operating temp
-10°C to +50°C / +14°F to +122°F
Storage temp
-20°C to +70°C / -4°F to +158°F
Humidity
10% to 90% (without condensation)
Ventilation
Thermostated fan cooling
12V 20A
LED
Mode
Status
Yellow
Absorption
The battery is charging. Time required
to complete absorption mode var-
ies, depending on the initial sate of
charge of the battery. It is limited to
6 hours
Flashing
yellow
Equalization
The battery is coming to the end of
the charging cycle. Time required to
complete equalization mode var-
ies, depending on the initial sate of
charge of the battery. It varies from
30 minutes to 4 hours
Flashing
green
End
equalization
The battery is almost charged. Float-
ing mode will begin in less than 30
minutes
Green
Floating
The battery is completely charged
Red
Internal
temperature
fault
Battery
temperature
fault
The charger is on standby mode for
a period of between 30 seconds to
10 minutes. Once the fault has been
solved, the charger restart automati-
cally
> Please check the ambient tem-
perature (charger and/or battery) as
well as the internal fan and the place
around the charger
Flashing
red
Output
voltage fault
The charger is on standby mode for a
period of 30 seconds. Once the fault
has been solved, the charger restart
automatically
> The electronic board has probably
failed and the damage is irreversible
Flashing
red (quick
flash)
Output fuse
The output fuse should be replaced
> Please check the battery’s polarity
Flashing
green
(quick
flash)
Stand-by
The charger is not charging (no main
or stand-by mode)
Battery
Selector
Boost - float
Open lead
14,2V – 13,2V
AGM
14,9V – 13,8V
Gel
14,3V – 13,8V
Lithium normal
14,6V – 13,8V
Lthium high
15,0V – 14,2V
TECHniCAl SpECifiCATiOnS
OpERATing inSTRuCTiOnS
EMC
EN61000-6-3 & EN61000-6-1
Security
EN60335-2-29 (2002)
Housing
Aluminium type – wall mounted
Mounting
2 x 4mm screws
Dimensions (mm)
278 x 120 x 96
Weight
1.3 kg / 2.87lbs
Ac interface
3 x 1,5 mm
2
cable, lenght 1m
Battery interface
AWG12 cables, lenght 1m
T° sensor & carbus
interface
3 points terminal
Pin_out auxiliary
connector:
1 - carbus
2 - com
3 - t° sensor