2.4.8 Filter
After pressing
MENU
the display will show:
By pressing
up
or
down
arrow the filter constant can be set. The range is from 1 to 10.
2.4.9 Basic Menu Settings.
The factory default settings is suitable for most general applications.
Recording interval 5 s
Initialising the measurement with the deceleration threshold
Threshold value 20 %
Display contrast higher
Background lighting yes
Time and Date set in the factory
Header of the report set in the factory
Auto switched on
Filter multiplicity 1
After the setting the decelerometer can be placed into the vehicle, switched-on and
leveled into the horizontal position. The vehicle can be moved to the required speed
and the key
MEAS
pressed. When the vehicle stops due to the function of its own
braking system, the report of the measurements will be printed. The recording time is 5
sec. The measurements will start at the beginning of the braking action.
17
Setting of
filter
Multiplicity :