![Car-O-Liner CMI 300 Pulse Boost User Manual Download Page 16](http://html1.mh-extra.com/html/car-o-liner/cmi-300-pulse-boost/cmi-300-pulse-boost_user-manual_2555229016.webp)
16
Technical data 1
1) This equipment complies with IEC 61000-3-12 provided that the short-circuit power Ssc of the grid at the interface point is greater than or equal to the stated data in the
abovementioned table. It is the responsibility of the installer or user of the equipment to ensure, by consultation with the distribution network operator if necessary, that the
equipment is connected only to a supply with a short-circuit power Ssc greater than or equal to the stated data in the abovementioned table.
2)
S
This machine meets the demand made for machines which are to operate in areas with increased hazard of electric chocks.
3) Equipment marked IP23S is designed for indoor and outdoor applications.
Power source
CMI 300 Pulse
CMI 300 Pulse Twin
CMI 300 Pulse Trio
Mains voltage ±15% (50-60Hz), V
3x400
3x400
3x400
Minimum generator size, kVA
16
16
16
1)
Minimum short-circuit power, MVA
3.7
3.7
3.7
Fuse, A
10/16
10/16
10/16
Mains current effective, A
8.5
8.5
8.5
Mains current max., A
15.3
15.3
15.3
Power 100%, kVA
5.8
5.8
5.8
Power max., kVA
10.6
10.6
10.6
Power open circuit, W
30
35
40
Efficiency
0.86
0.86
0.86
Power factor
0.93
0.93
0.93
Current range, A
15-300
15-300
15-300
Duty cycle 100% 20°C, A/V
250/26.5
250/26.5
250/26.5
Duty cycle max. 20°C, A/%/V
300/60/29.0
300/60/29.0
300/60/29.0
Duty cycle 100% 40°C, A/V
200/24.0
200/24.0
200/24.0
Duty cycle 60% 40°C, A/V
230/25.5
230/25.5
230/25.5
Duty cycle max. 40°C, A/%/V
300/20/29.0
300/20/29.0
300/20/29.0
Open circuit voltage, V
50-60
50-60
50-60
2)
Sphere of application
S/CE
S/CE
S/CE
3)
Protection class
IP23S
IP23S
IP23S
Standards
IEC60974-1. IEC60974-5. IEC60974-10 Cl. A
Dimensions (HxWxL), mm
838x443x1003
1104x597x1003
1104x597x1003
Weight, kg
49
63
67
Wire feed speed, m/min
0.5-30.0
0.5-30.0
0.5-30
Torch connection
EURO
EURO
EURO
Wire dimension, mm
0.6-1.6
0.6-1.6
0.6-1.6
Wire spool diameter, mm
300
2x300
3x200
Wire spool, kg
5-18
2x5-18
3x5
Gas pressure, max., MPA (bar)
0.6 (6.0)
0.6 (6.0)
0.6 (6.0)
FUNCTION
PROCESS
VALUE RANGE
Selection of trigger mode, 2-times / 4-times
MIG/MAG
2/4
Gas pre-flow, sec.
MIG/MAG
0-10
Soft-start, m/min
MIG/MAG
0.5-24.0
Hot-start, %
Synergic
-99-(+)99
Hot-start-time, sec.
Synergic
0-20
Slope down time, sec.
Synergic
0-10
Final current, %
Synergic
0-100
Final current time, sec.
Synergic
0-10
Gas post-flow, sec
MIG
0-20
Spot welding time, sec.
MIG
0-5.0
Step welding time, sec.
MIG
0.1-5.0
DUO Plus™ value
MIG
1-50
Electronic choke
MIG
-5-(+)5