![CAR-connect LDC.22-500 Operating Manual Download Page 43](http://html1.mh-extra.com/html/car-connect/ldc-22-500/ldc-22-500_operating-manual_2555104043.webp)
Operation
41.CC.2210.3042_BA_V00_EN
43
The table below provides information about the steps you can take to resolve these faults.
It may be necessary to finish charging first (see the “Finishing charging” section).
If the fault messages cannot be resolved, contact the manufacturer immediately.
Message
Meaning
Corrective action
An insulation fault
was detected in the
connection to the
vehicle.
If the fault message
persists, the current
charging process will
be aborted after 90
seconds.
By the operator or a high voltage specialist:
•
Inspect the vehicle.
•
Perform vehicle diagnostics.
Over- circuit is de-
energized
The voltage in the
DC circuit is above
DC 600 V. The
device switches off
automatically.
By the operator or a high voltage specialist:
•
Inspect the vehicle.
Fault DC/DC
The AC/DC
converters cannot be
controlled.
By an electrician:
•
Check the power supply
connection.
By the operator:
•
Contact the manufacturer.
EMERGENCY
STOP pressed
The emergency stop
button was pressed.
Remedy the reason for the emergency stop
button being pressed and restart the
charging process.
N conductor fault
A fault was detected
in the neutral
conductor in the AC
circuit.
By an electrician:
•
Check the power supply
connection.
By the operator:
•
Check the miniature circuit
breakers for the power supply
connection.
•
Contact the manufacturer.
Phase fault
There is a fault in at
least one phase in
the AC circuit.
By an electrician:
•
Check the power supply
connection.
By the operator:
•
Contact the manufacturer.