Caple WI152 Technical Information Download Page 1

WI152

Caple 15cm wine cabinet

Technical information

Summary of Contents for WI152

Page 1: ...WI152 Caple 15cm wine cabinet Technical information...

Page 2: ......

Page 3: ...Cover 1 13 DG3 42 PCB board 1 14 DG13 348 Button gasket 1 15 DG20 258 Display panel 1 16 DG13 130 S Button 4 17 DG23 157 Cabinet door 1 18 DG22 3027 cylinder knop 1 19 M184 027 Gasket 1 20 DG15 139 S...

Page 4: ......

Page 5: ...ttempting any cleaning or maintenance this unit MUST be disconnected from the electrical supply to prevent electrical shock Preparation before maintenance Tools 1 Pliers 2 Phillips head screwdrivers 3...

Page 6: ...ist below Below we list the symbols and explain the danger if ignore it Danger This symbol means that the instance may have the chance to suffer death or a serious wound Warning This symbol means that...

Page 7: ...the systems and cause blast Exhaust the rest refrigerant in the systems before welding After filling the refrigerant the sealing should be done by using smithing welding nozzle Using the welding mach...

Page 8: ...place without fire before disusing the refrigerant bottle Don t touch the wine cooler when the cooling pipe damaged don t fie inside the wine cooler keep the windows open to exchange the air Disusing...

Page 9: ...he pipe sometimes are very hot And the heating or just stop heater is very hot The hot will cause scald Attention the hot parts of the pipe after the welding Attention the refrigerant during charge an...

Page 10: ...6 23 2 Electrical circuit diagram 3 Cooling system diagram...

Page 11: ...ess DOWN the setting temp will lower down in 1 5 How to diagnose the fault 5 1 Fault finding by the self check mode The wine cooler is controlled by computer in order to maintain the wine cooler easil...

Page 12: ...r sensor open circuit Check the wiring and connection between PCB and sensor if it open circuit If the connection and wiring is normal replace the sensor please E2 Inner sensor short circuit Check the...

Page 13: ...Yes No No Yes Yes Yes No If the inner light can be turn on Check the power source power cord plug socket Display error code Refer to 5 2 The starter have power input The protector have power input Che...

Page 14: ...helves Remove the air duct board Remove two air duct board fixing screws and remove the air duct board disconnect the fan connector carefully when pulling out the air duct board Fig 2 No Yes No Yes No...

Page 15: ...and the fan can be removed Fig 3 6 1 4 How to remove the sensor The process remove the shelves remove the air duct board remove the sensor After remove the air duct board loose the sensor fixing screw...

Page 16: ...PCB The process Remove the shelves remove the control box remove the main PCB After removing the control box press the nail one by one and pull the PCB upward remove the main PCB Fig 5 Diagram and ex...

Page 17: ...sformer The process of removing the power PCB remove the power PCB cover disconnect the connectors remove the power PCB The process of removing the transformer remove the power PCB cover disconnect th...

Page 18: ...xplanation of power PCB and connection Fig 10 Fig 8 L Power L N Power N X6 Transformer primary X16 Transformer secondary X3 Compressor X15 Outer fan X12 Main PCB Fig 10 Power PCB cover Transformer Pow...

Page 19: ...move the cabinet legs remove the compressor fixing screws Release the refrigerant by cutting the process pipe C then heat the suction pipe and separate it by using the plier heat the filter and conden...

Page 20: ...or Fig 16 Heat the solder joint A D separate them by using the plier Fig 13 Remove the evaporator fixing screws remove the evaporator Fig 16 Fig 13 Fig 15 A A Suction pipe solder joint B Filter and co...

Page 21: ...e the compressor supporter remove the condenser Refer to the method of remove the compressor after remove the whole compressor and it s supporter separate the compressor and condenser on point E pull...

Page 22: ...rge pipe if the obvious air pressure from compressor if the current still very high or very low or the discharge pipe with small air pressure the compressor fault replace the compressor please Notice...

Page 23: ...anti dew pipe another is the damage on the spare parts in the cooling system If it is the inner damage it can not be repaired and if the damage on the spare parts replace them 3 Make sure there is no...

Page 24: ...e maintained or replaced 6 2 3 2 If compressor s shock absorption rubber is hardening or damaged or fixing screw of compressor is too tight or loose it will cause noise The settlement is to change new...

Page 25: ...ing system pipe work probably due to the capillary slightly out of alignment during transportation Solution Clean the cooling system pipe vacuumize it and recharge with refrigerant see 7 3 7 9 Evapora...

Page 26: ...the sensor 6 1 4 1 After turning on the power if the LED display shows the temperature is similar with the ambient temperature it is normal if abnormal or show E1 E2 please remove the control box che...

Page 27: ...Explanation of display According to requirement there are two different display one is that the LED display show the setting temperature the other is that the LED display show the real inner temperat...