19/23
6.2.4
.
How to remove the outer condenser:
Process of removing the outer condenser: Remove four fixing screws
→
Remove the outer
condenser
Separate on A, H by
Soldering iron for copper pipes, separate the pipe using the plier, remove four
screws J, remove the condenser K.
(Fig.17)
7. How to overhaul the faults.
It should take approximate 3 hours to reach the lowest setting temperature of about 5
℃
(or 4
℃
) for an
empty unit (assuming ambient temp of 32 degrees centigrade and continuous operation). If not, check the
compressor, cooling fans, controller, and sensors. If all these are working normally, there is probably a
cooling pipe fault.
7.1. Check the compressor
If the wine cooler not cooling, check the current with the Amp meter
,
refer to rating label,
if it too high or too low, cut the discharge pipe
(Fig. 17 item F)
and
(Fig.12 item B)
,
power on, check the current, and feel the discharge pipe, if the obvious air pressure from
compressor, if the current still very high or very low or the discharge pipe with small
air pressure, the compressor fault, replace the compressor please.
Notice. After cut the discharge pipe and process pipe, in case of suck the damp, the
compressor should ne power on long time (no exceed 15 minutes is best).
7.2. Check the cooling system
When it is sure that the compressor is working normally and the cooling system
’
s fault is concentrating on
the cooling system pipe. Check following below:
A
B
C
E
F
G
H
J
K
Fig.17