background image

5

If  the  fixed  appliance  is  endowed  with  a  supply 

cord and a plug, the appliance has to be put in a 

place where the plug can be reached easily.

*  The  use  of  materials  which  can  burst  into 

flames should  be  avoided  in  close  proximity 

of  the  appliance.  When  frying,  please  pay 

particular  attention  to  fire  risk  due  to  oil 

grease.  Being  highly  inflammable,  fried  oil  is 

especially  dangerous.  Do  not  use  uncovered 

electric grills.

In  order  to  avoid  possible  fire  risk,  all 

instructions  for  grease  filter  cleaning  and  for 

removing eventual grease deposits should be 

strictly followed.

WARNINGS

*

The appliance is not intended for use by 

young children or infirm persons without 

supervision. Young children should be 

supervised  to  ensure  they  do  not  play  with 

the appliance.

*

The cooking surface and the inferior part of 

the cooker hood must be at a minimum 

distance of 65 cm.

*

The extracted air cannot be conveyed 

through  or  into  a  duct  used  to  let  out 

fumes from appliances fed by energy other 

than electric power (eg centralized heating, 

radiators, water heaters, etc).

*

To evacuate the air outlet, please comply 

with the pertaining rules given by competent 

authorities.

*

Provide the room with an adequate ventilation 

when  a  cooker  hood  and  appliances  fed  by 

energy other than electric power (gas, oil, or coal 

stoves, etc.) are used simultaneously. The cooker 

hood, when evacuating the extracted air, could 

generate a negative pressure in the room  which 

can’t  exceed  the  limit  of  0.04mbar, in order to 

avoid the suck of exhausts deriving from the heat 

source. Therefore the room should be provided 

with air intakes to allow a constant flow of fresh 

air.

*

When performing the electrical connections on 

the appliance, please make sure that the current 

tap is provided with earth connection and that 

voltage values correspond to those indicated on 

the rating label placed inside the appliance itself.

*

Before carrying out any cleaning or 

maintenance  operations,  the  appliance  needs 

to be removed from the electric grid. If the 

appliance is not provided with a non separable 

flexible cable and plug, or with another device 

ensuring omni-polar disconnections from the  grid, 

with  an  opening  distance  between the contacts 

of at least 3 mm, then such disconnecting 

devices must be supplied within the fixed 

installation. 

USES

The appliance is already arranged both for 

filtering and for suction performances.

*

In its filtering version (Fig.1), the air and 

fumes conveyed by the appliance are cleaned 

both by a grease filter and by an active 

charcoal filter, and put again into circulation 

through the side vents of the chimney. For 

this version  an  air  deflector  placed  on the 

superior part of the pipe and allowing air 

recycling is necessary (Fig.1A).

*

In its vented version (Fig.2), fumes are 

directly conveyed outside, through an 

evacuation duct connected with the superior 

part of the wall or the ceiling. Both charcoal 

filter and air deflector are not necessary in this 

case.

 

Summary of Contents for PI402

Page 1: ...Instruction manual for Island hood Model PI402 Contact Caple on 0117 938 7420 or for spare parts www caple co uk ...

Page 2: ......

Page 3: ...rectly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product For more detailed information about recycling of this product please contact your local city office your household waste disposal service or the shop where you purchased the product This appliance is marked according to th...

Page 4: ...CONTENTS Warnings Uses Installation Working Maintenance 4 ...

Page 5: ...racted air could generate a negative pressure in the room which can t exceed the limit of 0 04mbar in order to avoid the suck of exhausts deriving from the heat source Therefore the room should be provided with air intakes to allow a constant flow of fresh air When performing the electrical connections on the appliance please make sure that the current tap is provided with earth connection and tha...

Page 6: ... the display cable strap Put down the lower pipe while paying attention it is being properly introduced into the hood Lift the upper tube Fig 7 5 up to the ceiling and insert the two self tapping screws Fig 7 5 D Warning Before connecting the ducting pipe to the motor make sure the stop valve which is on the air outlet of the motor can swing INSTALLATION Before installing the appliance make sure t...

Page 7: ...y Learning the new transmission code Once the transmission code is changed in the radio control unit the electronic central unit of the cooker hood must be made to set the new code in the following way Press the main power off button of the hood and then restore power to the electronic control unit Within the next 15 seconds press the Light Button to synchronise the central unit with the code Rese...

Page 8: ...ial handle toward the back side of the cooker hood and turning the filter downwards so to unfasten it from its slot Fig 3A This can be cleaned by hand with warm soapy water or cleaned in the dishwasher To insert the filter just perform the opposite operation In the case the appliance is used in recirculation mode the active charcoal filter Fig 8Z needs to be periodically replaced The charcoal filt...

Page 9: ...9 ...

Page 10: ...10 1 2 4 3 ...

Page 11: ...11 5 6 7 5 3 5 2 5 1 7 6 7 5 7 4 7 3 7 2 7 1 ...

Page 12: ...12 8 9 11 10 12 16 17 13 14 15 17 13 14 15 ...

Page 13: ...47 13 ...

Page 14: ...47 14 ...

Page 15: ...15 ...

Page 16: ...Caple Fourth Way Avonmouth Bristol BS11 8DW www caple co uk T 0117 938 7420 90002422415 Serial number 90004220401 08 16 ...

Reviews: