background image

5

Instruction manual PH500H

Please keep this instruction manual for future reference 

E N V I R O N M E N TA L   P R OT E C T I O N    

Waste electrical products should not be disposed of with household waste. Please recycle 
where facilities exist. Check with your Local Authority or retailer for recycling advice. This 
appliance is marked according to the European Directive on Waste Electrical and Electronic 
Equipment (WEEE).

By ensuring this product is disposed of correctly, you will help prevent potential negative 
consequences for the environment and human health, which could otherwise be caused 
by inappropriate waste handling of this product. The symbol on the product indicates that 
this product may not be treated as household waste. Instead it shall be handed over to the 
applicable collection point for the recycling of electrical and electronic equipment. Disposal 
must be carried out in accordance with local environmental regulations for waste disposal.

For more detailed information about treatment, recovery and recycling of this product, please 
contact your local council, your household waste disposal service or the retailer where you 
purchased the product.

C E   D E C L A R AT I O N S   O F   C O N F O R M I T Y  

This appliance has been manufactured to the strictest standards and complies with all 
applicable legislation, Low Voltage Directive (LVD) and Electromagnetic Compatibility (EMC).

U K C A   D E C L A R AT I O N S   O F   C O N F O R M I T Y  

 

This appliance has been manufactured to the strictest standards and complies with all  
applicable legislation. 

WA R R A N T Y

Your new appliance is covered by warranty. The warranty card is enclosed - if it is missing, you 
must provide the following information to your retailer in order to receive a replacement: date 
of purchase, model and serial number (placed on the inside of the appliance storage drawer). 
Registration can also be completed online by visiting www.caple.co.uk. 
Ensure you keep your warranty card safe, you may need to show it to Caple Service together 
with proof of purchase.  
If you fail to show your warranty card you will incur all repair charges.  
Spare parts are only available from Caple Service and spare parts authorised centres.

Summary of Contents for PH500H

Page 1: ...Hydronic Plinth Heater Instruction Manual Contact Caple on 0117 938 7420 for spare parts or www caple co uk PH500H ...

Page 2: ...al PH500H Please keep this instruction manual for future reference C O NT ENT S Safety Instructions 3 Environmental Protection 5 Fitting Instructions 6 Troubleshooting 10 Care and Maintenance 11 Caple Contact Details 12 ...

Page 3: ...rvised and given appropriate instruction concerning the use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance should not be carried out by children without supervision Children less than 8 years of age should be kept away unless continuously supervised The appliance and its accessible parts become hot during ...

Page 4: ...eakfast type environments Ensure that the supply cord is not wedged during the installation If the supply cord is damaged it must be replaced by a Caple service technician or similarly qualified persons in order to prevent a hazard Do not use harsh abrasive cleaners or sharp metal scrapers to clean the grille as this may damage or scratch the surface Ensure the appliance is switched off before any...

Page 5: ...formation about treatment recovery and recycling of this product please contact your local council your household waste disposal service or the retailer where you purchased the product CE DECLARATIONS OF CONFORMITY This appliance has been manufactured to the strictest standards and complies with all applicable legislation Low Voltage Directive LVD and Electromagnetic Compatibility EMC UKCA DECLARA...

Page 6: ...Y Supply should be through a 2 x 15mm pipe pumped central heating system The connection points to the central heating pipework should always be to the side of the plinth heater and in a position so when the heater is fully fitted the flexible hoses will not be kinked and the hoses will have as large a radius as possible STEP 3 PREPARATION This product is normally fitted directly onto the floor Onc...

Page 7: ...ualified electrician and Electrical installation must comply with local and national regulations STEP 5 WATER CONNECTIONS Connect the valve end of the flexible hoses to the Plinth Heater Note the direction of flow arrows on the valves are not important in this application Always use 2 spanners to tighten the valves to the plinth heater as using only one spanner may damage the copper pipe and block...

Page 8: ...ut of the air vent during this process Close the vent screw ensuring that there are no leaks NOTE You may need to balance the central heating system if the plinth heater is installed on the same circuit as panel radiators STEP 7 FITTING Ensuring that the flexible hoses do not kink and the electrical cable is not in contact with any hot surfaces slide the plinth heater under the cupboard until the ...

Page 9: ...l start to rotate provided hot water is circulating through the heat exchanger at or above 43 C If the central heating system has just been switched on there may be a delay in the fan starting until the central heating hot water reaches 43 C When the central heating system switches off and the system temperature drops below 43 C the fan will stop automatically During the summer the plinth heater c...

Page 10: ...iring connections at the fused spur HEATER DOES NOT SWITCH ON WHEN CENTRAL Check the top switch is set to 0 and the bottom switch is heating is on is set to I or II Check the unit is not air locked Use bleed valve in front of the unit to release any air Balance the central heating system if installed on same circuit as panel radiators and increase the circulating pump speed if required Increase th...

Page 11: ...nance should be restricted to dust and lint removal around the unit Do not tamper with any electrical parts A Caple approved engineer should be used for other maintenance requirements TECHNICAL DATA Test Pressure 10 bar Maximum working pressure 8 bar Electrical supply 220 240 V 50 Hz Water connections 15mm compression Heat output 3057 3979 Btu 0 9 1 17kW Maximum working pressure 8bar 1Mpa Fuse rat...

Page 12: ...Caple Service Fourth Way Avonmouth Bristol BS11 8DW T 0117 938 1900 E service caple co uk www caple co uk ...

Reviews: