Error Code
Description
Potential Failure
Measure
What to do…
E 5
Network failure
Overvoltage
Check the voltage
E 6
Network failure
Frequency problem
Overvoltage
Check the frequency
Replace the generator
E 8
Fan failure
Fan or control electronics
defect
Replace the generator
E 9
Temperature probe PT 1000
Temperature probe PT 1000 is
defective
Replace the generator
E A
Hardware failure
Hardware failure
Replace the generator
E H
Fixed resistor recognition
If there is no temperature
change at the cook place after
activation of cooktop within 5
minutes, error display shows
message “E H“
Induction cooktop has to cool down
U400
Overvoltage
Wrong connection 400V
Disconnect and correct the power line
connection
Caple C864I 78cm Induction Hob